INSTRUCTION MANUAL
WORK TABLES
(Manual and Electric Height Adjust)
Read and understand all of the instructions and safety
information in this manual before operating this product.
03/2018
MAN-070 REV A
© 2017 MAC Medical, Inc.

Advertisement

loading

Summary of Contents for Mac Medical WT0004

  • Page 1 INSTRUCTION MANUAL WORK TABLES (Manual and Electric Height Adjust) Read and understand all of the instructions and safety information in this manual before operating this product. 03/2018 MAN-070 REV A © 2017 MAC Medical, Inc.
  • Page 2: Description Of Product

    Replacement Parts - General Limited Lifetime Warranty DESCRIPTION OF PRODUCT PURPOSE OF THIS MANUAL This manual covers MAC Medical Work Tables wth This manual covers the operation and Manual or Electronic Height Adjust Options. maintenance of the Mac Medical Work Tables with the Manual or Electronic Height Adjust Options.
  • Page 3 Instruction Manual STANDARD FEATURES - WORK TABLES MAC Medical Work Tables come Standard with: • Fully welded construction Reinforced stainless steel top • Reinforced stainless steel top (16 gauge type 300 series) Manual height • Stainless steel under shelf (18 gauge type 300...
  • Page 4: General Specifications

    Instruction Manual GENERAL SPECIFICATIONS Power Requirements: 120 Volt, 60 Hz, single phase, 15 amp GFCI protected electrical outlet, installed per local building codes, and provides protective grounding. UL Approved: All individual electronic components are UL approved and/or recognized. Table Installation Work Tables with the Electronic Height Adjustment Option require a power source to operate the hydraulics system.
  • Page 5: Unpacking Instructions

    Instruction Manual UNPACKING INSTRUCTIONS Inspection 1. Receiving area must meet all State and Local regulations prior to unpacking. 2. Customer must inspect skid and Table both before and after unpacking to determine if any items were damaged during shipping. 3. All damaged items must be listed on the Bill of Lading.
  • Page 6 Instruction Manual MINIMUM/ MAXIMUM ADJUSTABLE HEIGHTS FOR A WORK TABLE Minimum/ Maximum Adjustable Height, Manual Height Adjustment The Minimum height of a Manual Height Adjust Work Table is 36” (from floor to tabletop). The Maxumim height of a Manual Height Adjust WorkTable is 55” (from floor to tabletop). 55” Fig. 3: Manual height adjust minimum/ maximum heights. Minimum/ Maximum Adjustable Height, Electronic Height Adjustment The Minimum height of an Electronic Adjust Work Table is 36” (from floor to tabletop) The Maximum height of an Electronic Height Adjust Work Table is 43” (from floor to tabletop). Fig 4: Electronic height adjust minimum/ maximum heights. MAN-070 www.macmedical.com...
  • Page 7 Instruction Manual HEIGHT ADJUSTMENT - MANUAL HYDRAULIC PUMP WITH HANDCRANK For Space Saver Tables equipped with the Optional Manual Hydraulic Pump with Handcrank (Fig. 5-6), the Handcrank can be folded to disappear under the table. 1. Crank the table to the desired height 2.
  • Page 8 Instruction Manual HEIGHT ADJUSTMENT - MOTORIZED ADJUSTABLE HYDRAULICS Work Tables with Electroic Adjustable Height Option - Control Panel Technical Data The Control Panel feature is available for a Work Table with the Electronc Adjust Option to operate its hydraulics. Features Electrical Specifications 4 Memory Positions Primary Voltage 120V, 10A...
  • Page 9 Instruction Manual Work Tables with Electronic Adjustable Height Option - Control Panel Setup and Operation Fig. 9: Memory Control Keypad At the first power-on, follow these steps: Note: US customers will see the values in the display in terms of US inches. European customers will see display values in terms of EU Centimeters.
  • Page 10 Instruction Manual Work Tables with Electronic Adjustable Height Option - Control Panel Setup and Operation (continued) 3. Saving of a position a. This function allows the user to save a particular operating height on one of the four preset buttons. b.
  • Page 11 Instruction Manual Replacing the Memory Control Pad Fig. 10: Remove old Memory Control Pad Removing the Existing Memory Control Pad If the Memory Control Pad must be replaced (due to damage), first remove the existing Memory Control Pad: UNPLUG THE TABLE FROM ITS POWER SOUCE. 2. Remove four 1/4” screws attaching the Controller to the table mounting plate (Fig. 10). 3.
  • Page 12 Instruction Manual Installing the Replacement Memory Control Pad 1. Position the replacement Memory Control Pad on the mounting plate under the front edge of the table. Align the four holes in the control panel with holes in table mounting plate. 2.
  • Page 13 Instruction Manual Programming the Replacement Memory Control Pad After the new Memory Control Pad has been installed, it must be programmed. HOLD AT THE 1. Press and hold Buttons “1”, “2”, and the “UP” Arrow at the same SAME TIME time. The Memory Control Pad is now in the adjustment mode. 2. Release Buttons “1”, “2”, and the “UP” arrow. Press the “UP” arrow RELEASE until the display reads “S7”.
  • Page 14 Instruction Manual Instructions for Cleaning Stainless Steel Tables Stainless Steel tables must be cleaned on a regular basis to prevent any unnecessary damage to the stainless steel surfaces. When cleaning stainless steel tables, make sure to use the proper approved cleaning agents and cleaning materials.
  • Page 15 Instruction Manual Replacement Parts - General The Work Table replacement parts listed on this page have been identified by MAC Medical as serviceable by facility personnel and are available for purchase. To obtain MAC Medical certified parts and authorized services, contact your MAC Medical representative. Item ID Part Number Description QTY. Models H0135-5-SS 5” Swivel Caster H0135-5-LSS 5” Swivel Caster w/Brake H0090-03 Hydraulic Pump with crank MAN-070 www.macmedical.com...
  • Page 16 EXPRESS OR IMPLIED, OF FITNESS AND / OR MERCHANTABILITY OR ANY OTHER WARRANTY IMPLIED BY CUSTOM, USAGE OR COURSE OF DEALING. Liability of MAC Medical under this warranty is limited to the repair and / or replacement of any products. MAC Medical specifically excludes and disclaims any responsibility for any incidental or consequential damages claimed to have arisen from any defect in workmanship or materials.