Table of Content Technical Specifications ............................3 PowerFlow Blowing Machine ........................ 3 Hydraulic Control Unit ..........................4 Big Flow Blowing Junction Block ......................5 Identification ................................6 Application ................................6 Mounting ................................6 Supply of Air or Water Pressure .......................... 7 Blowing a Fiber Cable into a Duct ........................
Technical Specifications These specifications cover PowerFlow as well as the hydraulic control unit and the blowing junction block for microducts. The blowing junction block is a replaceable format part that must fit the actual size of the fiber cables/microducts and ducts in question.
Hydraulic Control Unit Manufacturer Fremco A/S Ellehammervej 14 9900 Frederikshavn Denmark Item No............................... 103-10041 Hydraulic connection ......................0>125 bar, 17 l/min Manometer ..............................160 bar Hose to fiber blowing machine ......................1500 mm Hose to hydraulic pump ........................1500 mm Length ................................
Identification Make sure to place the Powerflow machine on These instructions have been made to support a stable foundation and to fasten it to the users of the cable blowing machine withstand the forces, which occur during use. PowerFlow. The machine type can be identified These push/pull forces can be up to 125 kg.
Preparing for Blowing Arrange the cable drum equipment approx. 10 m in front of the Powerflow. Check that the drum can turn easily and that the setup is stable. Start the hydraulic MultiPower Pack for cable blowing machines. Adjust to 50-75% power and let it run 2-5 minutes.
Turn on air to the blowing junction block – only for a short time – until the foam plug comes out at the other end of the duct. Turn on the hydraulic MultiPower Pack and start the Powerflow machine by moving the joystick on the hydraulic control unit ...
Maintenance The chain support rails must be replaced when The PowerFlow cable blowing machine does the side plates on the chain touch the support not require much maintenance, if a simple set rails. of rules is followed. It is very important to avoid any kind of dirt in...
Make sure the blowing junction block is Using other hydraulic power sources can properly connected to the duct and that the potentially cause damage on the Powerflow microducts/cable are placed correctly blowing machine. It is highly recommended to between the chains.