PMC-1302 ESG Ethernet Serial Gateway User Manual Version: V1.0A 06/21/2012 Ceiec Electric Technology...
Page 2
Ceiec Electric Technology This manual may not be reproduced in whole or in part by any means without the express written permission from Ceiec Electric Technology (CET). The information contained in this Manual is believed to be accurate at the time of publication;...
Page 3
Limited warranty Ceiec Electric Technology (CET) offers the customer a minimum of 12-month functional warranty on the device for faulty parts or workmanship from the date of dispatch from the distributor. This warranty is on a return to factory for repair basis.
Windows versions, the PMC-1302 ESG allows applications to directly connect to it via a TCP/IP connection for the transfer of serial packets inside TCP/IP frames to and from downstream serial devices. Perfectly suited for...
Before installation, make sure that the DIN rail is already in place Align the top of the mounting clip at the back of the PMC-1302 ESG at an angle against the top of the DIN rail as shown in the figure below ...
Figure 2-3-2 DIN-Rail Mounting 2.4 RS-485 Wiring The PMC-1302 ESG provides one RS-485 port (P2) and one RS-485 / RS-422 port (P3). Up to 32 devices can be connected on a RS-485 bus. The overall length of the RS-485 cable connecting all devices should not exceed 1200m.
Ceiec Electric Technology 2.6 Ethernet Wiring 2.6.1 Straight through Connection The following figure illustrates the definition of an 8-pin RJ45 straight through cable. The wiring sequence from pin 1 to pin 8 is orange-white, orange, green-white, blue, blue-white, green, brown-white and brown.
Ceiec Electric Technology 2.7 Power Supply Wiring For AC supply, connect the live wire to the L/+ terminal and the neutral wire to the N/- terminal. For DC supply, connect the positive wire to the L/+ terminal and the negative wire to the N/- terminal.
3.2 Reset Button There is a Reset button at bottom of PMC-1302 ESG. Use a pointed object, such as a straightened paper clip or the tip of a ball-point pen to press the Reset button. Pressing and holding the Reset button for 1 second will cause the PMC-1302 ESG to initiate a reboot sequence.
Configure the IP Address and the Subnet Mask of the PC as 192.168.0.100 and 255.255.255.0 as shown below. Enter the IP Address of the PMC-1302 ESG in the Address input box of the Internet Explorer and then press <Enter>. The default IP address is 192.168.0.127.
Ceiec Electric Technology The PMC-1302 ESG’s Web Console Login page appears. Enter the User Name and Password. The default user name is “user”, and the default password is “123456”. Once the log-in credentials are confirmed, the following page appears. 4.2 Basic Settings The Basic Settings page is divided into 3 areas: Network Settings, P2 Settings and P3 Settings.
IP connection instead of the serial connection, meaning that the IP connection will be closed if there are no activities between the application software and the PMC-1302 ESG for the specified amount of time. This is to prevent a potential lock up of the IP connection at the PMC-1302 ESG if the application software fails to close the IP connection for some unknown reasons.
Restart on the left-hand pane and the following screen appears on the right-hand pane. Click on the Restart button to save your changes into memory. After restart, the user needs to re-enter the user name and password to log back into the PMC-1302 ESG’s Web Console. 4.6 Exit Click on the Quit button near the top right-hand corner as shown in the above figure to exit the Web Console.
5.2 Configuring the PMC-1302 ESG To configure the PMC-1302 ESG, the user can log on to its Web Console page via the Internet Explorer by entering the IP address of the PMC-1302 ESG’s Ethernet port in the browser’s address bar. For example, type http://192.168.0.127/...
Ceiec Electric Technology In this example, P2 of the PMC-1302 ESG is used. The PMC-660’s serial port has been configured with the following parameters: Type = RS-485 Baud rate = 9600 Data Bits = 8 Parity = Even Stop Bits = 1 It is important for the communications parameters of the PMC-1302 ESG’s P2 to be programmed to...
Page 18
Ceiec Electric Technology Properties icon to bring up the Site Properties dialog box. In this example, P1 of the PMC-1302 ESG is used, and Site 1 has been configured with the following parameters: Drive Type = MODBUS - RTU Protocol Master Site Driver,...
Page 19
SNF file from the pop-up dialog box. Click on the Save icon on the Tool Bar to save the current configuration into PecStar’s database. The PecStar software is now ready to communicate with the PMC-660 via P2 of the PMC-1302 ESG.
Ceiec Electric Technology Appendix C - Ordering Guide Contact us Ceiec Electric Technology Headquarters 8/F, Westside, Building 201, Terra Industrial & Tradepark, Che Gong Miao, Shenzhen, Guangdong, P.R.China 518040 Tel: +86.755.8341.5187 Fax: +86.755.8341.0291 Email: support.international@ceiec-electric.com Web: www.ceiec-electric.com...