Model - KM-PFR-9-06 / KM-PFR-9-12

SPECIFICATION

No of steps
Voltage Burden
Operation Voltage Range
Input Current Range
Current Burden
Power Factor Display
Power Factor Setting Range
C/K setting Range
Operation Time Display
Output contacts coils
Operation Temp. Range
Storage Temp. Range
Dielectric Strength
Withstanding Impulse Voltage
Electrical Transient burst
Connection
Phase
Outside Dimension
Weight
®
An ISO 9001:2008 Company
Navin com/D:Sandeep Gupta/New Catlog Dec 2011/KM-PFR-9-06 09-12.cdr
®
DIGITAL INTELLIGENT POWER FACTOR
G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA.
Sales Direct.: 022 -2 4156638,
Email : kusam_meco@vsnl.net,
The pioneers & leaders in high quality power factor controllers & maximum
demand controllers, now introduce 2 new economy models of power
factor controllers. These controllers have microprocessors for automatic
control of power factor. It has digital indication for power factor.

UNIQUE FEATURES :

Display : Power Factor
Simple Operation.
Automatic self adjustment for C/K value.
Different types of Operation sequence (1:1:1:1....) (1:2:2:2....) (1:2:4:4....)...
(1:4: 8...) ( 1: 1: 2 : 2 )...( 1 : 1 : 2 : 2..)...( 1 : 1 : 4 : 8..)...( 2 : 4:...( 1 - 1-
switching in sequential Sequence )
The set data is preserved for at least two months in the event of Power failure.
Model KM-PFR-9-06
6 steps
6 VA
AC 220 V ± 15 % & AC 415 V ± 15 %
AC 0.05 ~ 5A, max 6A
0.5 VA
Digital Display, RED LED, 14.2 mm height, 0.01PF Resolution.
CAP 0.90 ~ IND 0.90 ( Factory set 0.98 P.F.).
Automatic self adjustment for C / K value
10 ~ 240 sec. Delay time. ( Factory set 30 sec ).
AC 220V 5 A ( Max. AC 380 V, 5 A, typical )
0 ~ 60° C
-10 ~ 70° C
AC 220 V, 50 Hz, 1 minute, Input / Output / Ground
According to IEC 1000 - 4 - 5
According to IEC 1000 - 4 - 4
Plug in Terminal block
Single Phase or Three Phase
144 x 144 mm and 65mm ( Depth) as Per Din standard
About 1 kg
All Specifications are subject to change without prior notice
Tel. : 022-241224540, 24181649,
REGULATOR
Model KM-PFR-9-12
12 steps
7.5VA
Fax : 022 - 24149659
Website : www.kusamelectrical.com,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM PFR-9-06 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kusam-meco KM PFR-9-06

  • Page 1 ® DIGITAL INTELLIGENT POWER FACTOR REGULATOR An ISO 9001:2008 Company Model - KM-PFR-9-06 / KM-PFR-9-12 The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor.
  • Page 2 ® AUTOMATIC POWER FACTOR REGULATOR KM PFR-9-06 KM PFR-9-12 INSTRUCTION MANUAL...
  • Page 3 Power Supply Company. This so-called reactive energy is no real energy consumption. This inductive reactive current can be compensated by means of shunt capacitor bank using reliable and efficient KUSAM-MECO Power Factor Controller. The KUSAM-MECO Controller incorporates state-of-art microprocessor based technology and with built-in protective devices that permanently monitors and ensure the processor for trouble-free operation.
  • Page 4 SETTING PROCEDURE TECHNICAL DATA VIEW SETTING VALUE________________________________ Voltage range : AC 220V±15% & AC440V±15% By pressing for 2s, and then the following symbols will be shown Power consumption : 4.5 VA (KM-PFR-9-06), on the display subsequently : 7.5 VA (KM-PFR-9-12) DLY (switching delay time) STP (number of switching steps) Current range...
  • Page 5 FLOWCHART OF PARAMETERS________________________ Press both simultaneously Press both simultaneously – for 2s, access the flowchart for 2s, leave the flowchart of parameters of parameters Remark : Setting is applied to KM-PFR-9-06 Remark : Press for over 3s during setting the desired value, the value will Remark : All connected capacitors will be switched off in order be increased/ decreased by 5 numerical value...
  • Page 6 7. H.SP. : Y: Start-up Fast switching performance, ~Y Table of the C/K values for 380V In order to replace the gradual switching on/off capacitor step, there are two KV AR solutions to an extended life of both the contactors and the capacitors as follows. 1.
  • Page 7 2A Fuse Coil Each “KUSAM-MECO” product is warranted to be free from defects in material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of goods. In case any...

This manual is also suitable for:

Km pfr-9-12

Table of Contents