Great Lakes Case & Cabinet VCM5-FR Installation Instructions Manual

5" vertical cable management & accessories

Advertisement

Quick Links

VCM5-FR, VCM5-FO
5" Vertical Cable Management & Accessories
Installation Instructions
WeRackYourWorld.com
1.866.TRY.GLCC (879-4522)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VCM5-FR and is the answer not in the manual?

Questions and answers

Summary of Contents for Great Lakes Case & Cabinet VCM5-FR

  • Page 1 VCM5-FR, VCM5-FO 5" Vertical Cable Management & Accessories Installation Instructions WeRackYourWorld.com 1.866.TRY.GLCC (879-4522)
  • Page 2 Proper spacing is required when installing electrical equipment to avoid electrical shock. PARTS LIST: VCM5-FO & VCM5-FR COMPONENTS AND QUANTITIES ARE THE SAME FOR VCM5-FO AND VCM5-FR, EXCEPT WHERE SPECIFIED COMPONENT QTY. VCM5-FO CHANNEL OR VCM5-FR CHANNEL 5" CHANNEL COVERS VCM5-FO: 2;...
  • Page 3 BRACKET SET A1 COMPATIBILITY: Bracket Set A1 is compatible with the following Great Lakes racks: GLRR-1984**(VCM can mount to the front or back side of upright) 4P1224-** (VCM can mount to the front or back side of upright) 4PM6-** (VCM must mount to front of upright) 4PHD29 (VCM must mount to front of upright) MOUNTING BRACKET SET A1 MOUNTED TO THE FRONT...
  • Page 4 INSTRUCTIONS FOR BRACKET SET A1 1. Align the channel mounting brackets with the equipment rack (Figure 1). 2. To secure the channel in place, push the supplied #12-24 screws through the mounting bracket and screw into the equipment rack. 3. When assembling the 80” channel, carefully align the connecting tabs (Figure 2).
  • Page 5 5.23 5.13 BRACKET SET A2 Bracket set A2 is compatible with the following Great Lakes racks: VD4PM6-2436 VD4P1224-2436 VD4PHD-2436 CMR-45U16 SHOWN AT 3.09 CMR-45U 5.44 RECESS TO 5.09 5.19 SHOWN AT RECESS TO -2.79 MOUNTING BRACKET SET A2 TOWARDS THE FRONT DETAIL A OF THE UPRIGHT 5.23...
  • Page 6 INSTRUCTIONS FOR BRACKET SET A2 #8-32 1. Remove bracket set A1. Based on the rack that is being used, determine if the VCM will mount to the front or rear of the upright. Front or rear mounting will determine correct orientation of bracket set A2 (see page 5 for details).
  • Page 7 OPTIONAL ACCESSORIES Slack Spool VCM5-SL The Slack Loop Storage Organizer manages and stores excess cable for future use. The Organizer is moveable and can be installed to accommodate different size slack loops. 1. Slide the Slack Loop Storage Organizer over the fingers of the Vertical Slotted Duct (Figure 5).
  • Page 8 SAFETY INFORMATION 1. Never install wiring or components during a lightning storm. 2. Never install components in wet locations unless the components are designed specifically for use in wet locations. 3. Never touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.

This manual is also suitable for:

Vcm5-fo

Table of Contents