Medium Voltage Power Supplies
MCP - Series
up to power class 15kW
Operating Instructions
This instruction is only dedicated to electrical experts and people with a
suitable technical education, which are familiar with electrical risks and
can keep the risk for themselves and other people as low as possible.
For the operation of this unit only a.m. persons are admitted.
FuG Elektronik GmbH,
Tel.: +49(0)8039/40077-0
Am Eschengrund 11
D-83135 Schechen
Fax: +49(0)8039/40077-99
info@fug-elektronik.de
www.fug-elektronik.de
certified according
ISO 9001 : 2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MCP 14–2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FuG Elektronik MCP 14–2000

  • Page 1 For the operation of this unit only a.m. persons are admitted. FuG Elektronik GmbH, Am Eschengrund 11 D-83135 Schechen Tel.: +49(0)8039/40077-0...
  • Page 2: Table Of Contents

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series Content: Safety Instructions ....................... 3 General ..........................4 Setup Information ........................ 5 Preparation for commissioning .................... 5 Description ........................... 6 Front Panel, Controls ......................6 Rear side, Connections......................7 Assembly ..........................
  • Page 3: Safety Instructions

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 1. Safety Instructions The units of the series MCP deliver dangerously High Voltages! Ensure that nothing and nobody will be endangered by this High Voltage before putting the...
  • Page 4: General

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 2. General The units of the series MCP (Medium Voltage Chopper Power Supplies) are high stable DC- power supplies with low ripple. High Voltage Output ATTENTION! The units supply dangerously HIGH VOLTAGE!
  • Page 5: Setup Information

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 2.1 Setup Information Operating position The units may only be operated in horizontal position. Class of pollution The units are designed for the pollution class 1 (normal, not conductive pollution).
  • Page 6: Description

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 3. Description 3.1 Front Panel, Controls 19 14 10 12 18 17 16 13 15 11 MCP 14-2000 DC POWER SUPPLY 0...2000V 0...6mA VOLTAGE CURRENT SET VALUES TEMP...
  • Page 7: Rear Side, Connections

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 3.2 Rear side, Connections 0507100001-1 Figure: Rear side of a MCP 14 – 2000 unit. The dimensions of units with higher power and/or other voltages are different to this type. In this case the arrangement of the elements can be different as shown above.
  • Page 8 FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 0507100007-1 0507100001-2 Figure: Rear side of a MCP 5000 – 2000 unit. The dimensions of units with higher power and/or other voltages are different to this type. In this case the arrangement of the elements can be different as shown above.
  • Page 9: Assembly

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 3.3 Assembly The power supply consists of 4 main units:  Mains source and oscillating Unit  HV-transformer, HV-rectifier with filter, HV-divider and current measuring shunt  Control unit with measuring and control amplifier, reference voltage source, pulse width modulator, source for the control unit from the mains transformer and a ±15...
  • Page 10: Operation With Local Controls

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 4. Operation with local controls The unit delivers dangerously High Voltage! Please follow the safety instructions in section 1 Please notice in particular Load connection in section 2.2 If your power supply is equipped with one of the options “analog or digital...
  • Page 11: Options

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 6. Options 6.1 Analog Programming Features Controlling of voltage, current and output on/off by the analog interface. Provides the readout of actual values as analog voltages and latest control modes as digital status signals.
  • Page 12 FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series sources, i.e. PLC or PC plug-in cards (0V must be connected) The UNIT-ON command (Pins 12-6) must be connected implicitly. ATTENTION! If the unit is switched off or mains fails possibly existing output voltages or currents will not be displayed on the monitor terminals.
  • Page 13 FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series Versions of analog Programming Plug connection View of solder side Plug All voltages and currents are Standard 600V potential free 2kV potential free specified in DC Non-isolated Isolation maximal 30V against ground (see catalog „Options and Modification)“...
  • Page 14: Digital Interface Probus V (Option)

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 6.2 Digital Interface PROBUS V (Option) The flexible Interface System Probus V consists of two parts, that communicate over a fiber optic connection.  Unit ADDAT30 (short “ADDA”) is an AD/DA interface that controls the power supply.
  • Page 15: Technical Data

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 7. Technical Data All here stated data are valid for voltage and current control in internal operation. For changes of the technical data with the options analog and digital programming see corresponding sections.
  • Page 16: Calibration (Option)

    FuG Elektronik GmbH, Am Eschengrund 11, D – 83135 Schechen MCP -Series 8. Calibration (Option) Calibration Certificate All guaranteed data for our power supplies are tested in the factory and documented in an internal test protocol. On request we can offer optionally a calibration in our plant. In this case the customer receives a calibration certificate due to our ISO 9001 : 2008 certified quality system.

This manual is also suitable for:

Mcp 5000–2000

Table of Contents