Schweigen INGG60B Installation, Operation & Maintenance Instructions Manual

Cooktop/gas/glass/60cm

Advertisement

GAS COOKTOP
INSTRUCTION MANUAL
Installation / Operation / Maintenance
INGG60B
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
cooktop/GAS/glass/60cm
INGG60B (PGINGp4.0ZpZtAB)
(10.2017 / V2.0)
Page 1
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INGG60B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Schweigen INGG60B

  • Page 1 ............................... . . cooktop/GAS/glass/60cm INGG60B (PGINGp4.0ZpZtAB) (10.2017 / V2.0)
  • Page 2: Table Of Contents

    INDEX Welcome ��������������������������������������������������������� 3 Glass Top Safety Warnings ........16 Important Safety Information ���������������������� 4 Operation ������������������������������������������������� 17-18 Energy Efficiency ............17 How to Save Energy ��������������������������������������� 6 Choice of Cookware ..........17 Unpacking ������������������������������������������������������� 6 Cookware Lids ............17 Burner Control Dial ............
  • Page 3: Welcome

    WELCOME Thank you for purchasing this Schweigen IN appliance. IMPORTANT! To achieve the optimal performance from your The appliance should only be operated when appliance, and to avoid the risk of accident or you have read and understood this manual damage, it is essential to read this manual before thoroughly.
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION The appliance and its accessible parts become hot This appliance must be installed in accordance during use. Care should be taken to avoid touching with the applicable regulations and used only heating elements. in a well-ventilated room� Before you install and use the appliance, carefully read the This appliance is not intended for use by anyone operating instructions�...
  • Page 5 IMPORTANT SAFETY INFORMATION • IF YOU SUSPECT A GAS LEAK, DO NOT: Cooking with this appliance results in the emission light matches, smoke, turn on or off any electrical of heat and moisture in the room in which it is devices (door bell, light switch, etc.) and use installed.
  • Page 6: How To Save Energy

    HOW TO SAVE ENERGY UNPACKING Using energy responsibly not only saves money but The appliance was packed to protected it from also helps the environment. So let’s save energy! damage during transport. After unpacking, please And this is how you can do it: dispose of all elements of packaging in a way that will not cause damage to the environment.
  • Page 7: Disposal Of The Appliance

    DISPOSAL OF THE APPLIANCE This appliance is marked with the symbol of the crossed-out waste container. This marking indicates that the appliance must not be disposed of together with other household waste after it has been used. The user is obliged to hand it over to waste collection centre collecting used electrical and electronic goods.
  • Page 8: Description Of The Appliance

    Packaged Weight - 12kg Overall Dimensions - 48mm (H) x 520mm (D) x 600mm (W) Total Nominal Gas Consumption Model Natural Gas Universal LPG 4 Burner INGG60B 30.8 MJ/h 30.2 MJ/h Test Point Pressure Natural Gas 1.0 kPa Universal LPG 2.75 kPa...
  • Page 9: Installation

    INSTALLATION The following instructions are intended for a VENTILATION qualified professional installer. These instructions Ventilation must be in accordance with AS/NZS are intended to provide the most professional 5601 - Gas Installations. In general, the appliance installation and maintenance of the appliance. should have adequate ventilation for complete •...
  • Page 10: Minimum Clearance Measurements

    INSTALLATION MINIMUM CLEARANCE MEASUREMENTS A� OVERHEAD CLEARANCE — (Measurement A) Rangehoods and exhaust fans must be installed in accordance with the manufacturer’s relevant instructions. However, in no case should the clearance between the highest part of the hob of the gas cooking appliance and a rangehood be less than 600mm or, for an overhead exhaust fan, 750mm.
  • Page 11: Notes For The Installer

    INSTALLATION This appliance shall be installed only by authorised persons and in accordance with the manufacturer’s Carefully read the operating instructions installation instructions, local gas fitting supplied and follow all guidelines� regulations, municipal building codes, electrical wiring regulations, local water supply regulations, CAUTION! AS 5601 - Gas Installations and any other statutory regulations.
  • Page 12: Gas Connection

    B. The cooktop can be connected with a Flexible checks have been carried out, call the Schweigen Hose, which complies with AS/NZS 1869 (AGA Customer Service Team.
  • Page 13 INSTALLATION Cooktop installation must be in accordance with state and federal laws� WARNING! When installing the cooktop in the kitchen DO NOT fix the cooktop into the benchtop, install a partition panel, (see Fig.2A). benchtop with sealant, ie. sillicon, as this If the cooktop is to be installed above a built-in will void the warranty.
  • Page 14: Installing The Gas Cooktop

    INSTALLATION INSTALLING THE GAS COOKTOP 6. To properly secure the cooktop on 28mm thick benchtops use four fixing brackets (see Fig.4B). 1. Prepare an opening in the kitchen benchtop, as 7. Fit the cooktop into the benchtop opening. per the installation measurements (see Fig. 3) 2.
  • Page 15: Adapt The Cooktop To A Particular Type Of Gas

    INSTALLATION ADAPT THE COOKTOP TO A PARTICULAR In order to adapt the cooktop to another gas type: TYPE OF GAS - replace the nozzles (see table), If the cooktop is set up with a gas type different - adjust the valves for a reduced flow. to the gas type specified by the manufacturer, i.e.
  • Page 16: Adjust The Valves

    INSTALLATION ADJUST THE VALVES WARNINGS FOR THE SAFETY OF THE GLASS TOP To adjust the valves turn the control dial to “economic flame” position and ignite the flame. Remove the control dial and adjust the size of an economic flame with a screwdriver. In order to check the flame, heat up the burner on a full flame for about 10 minutes, and then turn the burner dial to an economic flame position.
  • Page 17: Operation

    OPERATION ENERGY EFFICIENCY COOKWARE LIDS To achieve significant energy savings, use the Placing a lid on top prevents heat from escaping appliance as per these operating instructions, make and thus reduces heating time. the appropriate adjustments and use suitable pots. Potential energy savings: Do not use cookware that protrudes over •...
  • Page 18: Adjust Flame

    OPERATION Using the cooktop equipped with igniter dials ADJUST FLAME • push down the dial of a selected burner until Flame from a properly adjusted burner is pale blue you feel resistance and turn left to the “large with a clearly outlined inner cone. You can adjust flame”position the flame by setting the dial to different positions.
  • Page 19: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Proper routine maintenance and cleaning Make sure that burner is correctly reassembled after cleaning. of the appliance can significantly extend its trouble-free operation. CORRECT Before cleaning or other maintenance work, always unplug the appliance or use the main INCORRECT electrical system circuit breaker to cut off power�...
  • Page 20: Service Request

    Calling the Technical Assistance Service FAULTY INSTALLATION Hotline It is not the responsibility of Schweigen to rectify In the event that the failure is not due to the any incorrect installations. A service call out fee faults mentioned in Trouble Shooting, contact will be charged for any Schweigen technician Schweigen’s Customer Service Team.
  • Page 21: In The Event Of A Gas Leak Or Suspect Fault

    IN THE EVENT OF A GAS LEAK OR SUSPECTED FAULT IN THE EVENT OF A GAS LEAK OR BURNER DOES NOT IGNITE, I CAN SMELL SUSPECTED FAULT LEAKING GAS • turn off the flat burner dials (see Fig.1 below) • turn off the burner dials (see Fig.1) •...
  • Page 22: Troubleshooting

    All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information.
  • Page 23 NOTES ................................
  • Page 24 8/3-4 Anzed Court, Mulgrave, Victoria 3170. Sales: 1300 881 693. Email: sales@schweigen.com.au. All Service, Warranty & Technical Enquiries Ph: 1300 829 066 (Lines Open Weekdays 9AM - 5.30PM AEST) Fax: 1300 881 639 Email: service@schweigen.com.au. www.schweigen.com.au © Schweigen Pty Ltd. 2017.