A+ Corporation, LLC. Genie Direct Drive 752 Installation & Operation Instructions

Advertisement

An ISO 9001:2008 certified company

Safety Warnings

!
Failure to abide by any of the safety warnings below may result in equipment failure or serious injury and death.
Do not exceed any equipment pressure ratings
}
The probe must be installed into the process line by means of the appropriate size female full port ball valve
}
Only the lowest wrench flats on the base, nearest to the NPT male threads, can be used when installing into the process ball valve
}
DO NOT use the wrench flats on the packing adjustment nut, located on the top of the base, for installation into process ball valve.
}
Not designed for external fire.
}
Prior to use in a system, a properly sized relief device is to be installed which limits the use to 110% of the MAWP.
}

Tools Required

1-3/8" open end wrench
}
7/16" open end wrench
}
(2) 7/8" open end wrenches
}
Tools Required
1-3/16" open end wrench
}

Fittings Required

Appropriate size female full port ball valve
}
Genie
Direct Drive 752
®
Installation & Operation Instructions
Manufacturing
A+ Corporation, LLC
Call for expert product application assistance:
41041 Black Bayou Rd.
Phone: (225)-644-5255 Website: www.geniefilters.com
Gonzales, LA 70737
Fax:
Contact
Information
(225)-644-3975 E-mail: sales@geniefilters.com
©
2010 A+ Corporation, LLC. All rights reserved.
SCC-752-InsInstallationOperation_0514

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Genie Direct Drive 752 and is the answer not in the manual?

Questions and answers

Summary of Contents for A+ Corporation, LLC. Genie Direct Drive 752

  • Page 1 Genie Direct Drive 752 ® Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Phone: (225)-644-5255 Website: www.geniefilters.com Gonzales, LA 70737 Fax: (225)-644-3975 E-mail: sales@geniefilters.com Safety Warnings Failure to abide by any of the safety warnings below may result in equipment failure or serious injury and death. Do not exceed any equipment pressure ratings The probe must be installed into the process line by means of the appropriate size female full port ball valve Only the lowest wrench flats on the base, nearest to the NPT male threads, can be used when installing into the process ball valve...
  • Page 2 Technical Specifications Technical Specifications Maximum pressure rating 3,750 psig Maximum temperature 225 ºF (107 ºC) Port sizes Auxiliary: 1/8” female NPT with vent valve installed from factory Probe lengths 8”, 12”, 24” 36” (for other lengths contact the factory) A: ~ 20”, 24“, 36”, 48” (refer to L &...
  • Page 3 Installation Instructions Step 1. Install to process valve Be sure the ball valve to the process line is closed Apply a thread sealant, such as Teflon Tape, to the male threads on the bottom of the probe ® Install the probe into the process ball valve using a 1-3/8” open end wrench ONLY on the lowest wrench flats on the base, nearest to the NPT male threads (see Figure 1) Step 2.
  • Page 4 Removing Probe for Service Step 1. Retract the probe Retract the probe by using the 7/16” open end wrench only on the wrench flats of the threaded probe. Turn the threaded probe until it comes to a noticeable stop in its original position. (See Figure 2) Step 2.
  • Page 5 Model Numbering & Additional Part Numbers Model Numbering & Additional Part Numbers Your model number is determined by your specific needs. Choose options below. Sealing material 0 = PTFE/Neoprene rubber (other materials available upon request) 3 = 3/4” NPT 4 = 1” NPT 6= 1.5”...

Table of Contents