Astria Rapture GTA36TEN Installation And Operation Instruction Manual

Rapture series b-vent decorative gas appliance gas burner log modules

Advertisement

P126750-01
P/N 126750-01 Rev. H 08/2018
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Installation and Operation Instructions
Rapture
Rapture
Rapture
C
US
Report No. F10-113
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
B-Vent Decorative Gas Appliance
TM
Chassis Models
TM
Rapture36
Rapture42
Gas Burner Log Modules
TM
GTA36TEN
GTA42TEN
GTA36TEP
GTA42TEP
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
Rapture50
GTA50TEN
GTA50TEP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rapture GTA36TEN and is the answer not in the manual?

Questions and answers

Summary of Contents for Astria Rapture GTA36TEN

  • Page 1 Installation and Operation Instructions Rapture B-Vent Decorative Gas Appliance Rapture Chassis Models Rapture36 Rapture42 Rapture50 Rapture Gas Burner Log Modules P126750-01 GTA36TEN GTA42TEN GTA50TEN P/N 126750-01 Rev. H 08/2018 GTA36TEP GTA42TEP GTA50TEP Report No. F10-113 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil.
  • Page 2: Table Of Contents

    To restrict access to a fireplace or stove, fœtales ou perturber la fonction reproductive. Pour plus install an adjustable safety gate to keep toddlers, d’information, aller sur www.P65Warnings.ca.gov young children, and other at-risk individuals out of and away from hot surfaces. Astria.us.com 126750-01H...
  • Page 3: Safety

    18. Do not operate fireplace if any log is broken. 19. Do not use a blower insert, heat exchanger insert or other acces- sory not approved for use with this fireplace. 20. Provide adequate clearances around air openings. 126750-01H Astria.us.com...
  • Page 4: Unpacking Rapture Series

    NOTICE: This appliance is not intended to be used as a primary source of heat. CAUTION: Do not connect appliance before pressure testing gas piping. Damage to gas valve Based on CSA P.4.1-2015 may result and an unsafe condition may be caused. Astria.us.com 126750-01H...
  • Page 5: Selecting Location

    Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T-handle type valve. 126750-01H Astria.us.com...
  • Page 6: Product Dimensions

    " 7" (267 mm) (178 mm) (242 mm) " 36" (915 mm) " (115 mm) (89 mm) 11" 1" (26 mm) " (1159 mm) (280 mm) " (185 mm) " (388 mm) Figure 3 - 36" Model RAPTURE36 Astria.us.com 126750-01H...
  • Page 7 " 7" (267 mm) (178 mm) (242 mm) " 42" (1067 mm) " (115 mm) (89 mm) 13" 1" (26 mm) " (1299 mm) (331 mm) " (216 mm) 17" (432 mm) Figure 4 - 42" Model RAPTURE42 126750-01H Astria.us.com...
  • Page 8 " 7" (178 mm) (267 mm) (242 mm) " 1" 50" (1270 mm) " (115 mm) (26 mm) 59" (1499 mm) (89 mm) 13" " (331 mm) (216 mm) 17" (432 mm) Figure 5 - 50" Model RAPTURE50 Astria.us.com 126750-01H...
  • Page 9: Pre-Installation Preparation

    5. Using screws or nails, secure fireplace to framing through flanges face. Brick, tile or other noncombustible materials located on sides of fireplace. may be applied to the face provided that any gap is between the material used and the face is caulked with a noncombustible caulking. 126750-01H Astria.us.com...
  • Page 10 SAFE (3.8 cm) ZONE Max. 3" (7.6 cm) 33° Figure 8 - Outside Air Kit Max. 6" (15.2 cm) Max. 9" (22.9 cm) Perpendicular 12" Wall (30.5 cm) Figure 10 - Side Clearances - Top View (Cross Section) Astria.us.com 126750-01H...
  • Page 11: Venting Installation

    Square Chase-Top with Slip Section Height ETLO-8DM Square Chase-Top with Mesh & Slip Section From Roof 60E-8DM 60° Offset and Return 30E-8DM 30° Offset and Return Figure 11 - Typical Terminations 12S-8DM Chimney Support Figure 13 - Chimney Pipes and Accessories 126750-01H Astria.us.com...
  • Page 12 Figure 14 - Firestop Spacer with Living Space Above Ceiling Outer Perimeter of If area above is an attic or insulated area, install Flashing firestop above framed hole. Underlap Shingles at Bottom Figure 17 - Flashing Installation Figure 15 - Firestop Spacer with Attic Space Above Ceiling Astria.us.com 126750-01H...
  • Page 13 NOTE: In rare instance there is a problem with side driven rain or wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft Shield) can be used with round terminations. Vent Collar Figure 20 - Installing Transition Pipe and Starter Collar 126750-01H Astria.us.com...
  • Page 14: Installation

    Figure 22, Page 15. WARNING: Before you proceed, make sure your gas supply is OFF. WARNING: For natural gas, never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas. Astria.us.com 126750-01H...
  • Page 15 IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting Equipment off the gas to the appliance. Shutoff Valve Valve on Module Figure 25 - Installing Gas Line 126750-01H Astria.us.com...
  • Page 16 6. Secure the firebrick wall using 2 of the retainers provided. The Leading bracket will slip underneath the metal lip on the top of the wall Brick and screw into the inner dome of the fireplace (Figure 28). Figure 28 - Installing Side Walls Astria.us.com 126750-01H...
  • Page 17 Grout mixture in the joint should now be flush with brick surface. If not enough grout is applied into each space, grout may fall out after burning. 7. Using a joint striker, smooth out grout line. Allow 72 hours before installing log/burner module. 126750-01H Astria.us.com...
  • Page 18 Gas Shutoff Kink Valve 1/2" NPT Incoming Gas Line Outlet Pressure Tap NOTE: 1) Wire connections not shown for clarity Set Screw 2) * 1/8" NPT Plugged Tapping Figure 31 - Connecting Incoming Gas Line to Flex Gas Line Astria.us.com 126750-01H...
  • Page 19 1. Disconnect fireplace and its individual equipment shutoff valve gas valve located on or near gas meter for natural gas fireplace from gas supply piping system. Pressures in excess of 1/2 psig or using compressed air. (3.5 kPa) will damage fireplace gas regulator. 126750-01H Astria.us.com...
  • Page 20 Scrap 5. Light fireplace (see Operation, Page 22). Check all other internal Material Volcanic Logs joints for leaks. stone 6. Turn off fireplace (see To Turn Off Gas to Appliance, Page 22). Figure 36 - Installing Floor Media Astria.us.com 126750-01H...
  • Page 21 Tighten screws. See Figure 40. Ash Lip Bottom Door Frame Ash Lip Screw Figure 40 - Adjusting Bi-Fold Doors Figure 38 - Installing Bottom Door Frame WARNING: Do not slam or strike doors. Damage can result in a hazardous condition. 126750-01H Astria.us.com...
  • Page 22: Operation

    3. Turn safety shutoff switch to the OFF position or press OFF on hand-held remote. 4. Put damper in full open position. 5. Fully open glass doors, if installed. Incoming Gas Line Equipment Shutoff Valve Figure 41 - Turning Equipment Shutoff Valve to the OFF Position Astria.us.com 126750-01H...
  • Page 23: Gas Control Module System

    44). Do not remove the adjustment screw. • see Troubleshooting, Page 26 Yellow Tipping Sensor Pilot Igniter Burner Figure 46 - Incorrect Burner Figure 45 - Correct Burner Flame Pattern Flame Pattern Figure 44 - Correct Pilot Flame Pattern 126750-01H Astria.us.com...
  • Page 24: Cleaning And Maintenance

    This will provide sufficient combustion air and maintain safe temperatures in firebox. Discontinue use of the appliance im- mediately if doors are damaged and contact a qualified installer for repair. Only doors certified with the appliance shall be used. Astria.us.com 126750-01H...
  • Page 25 Pushing the handle forward and down will lock damper blade closed. Damper must be locked in the full open position before operating fireplace (see Figure 48). Damper Weight Damper To Close Weight Damper To Open Damper Figure 48 - Operating Damper Handle 126750-01H Astria.us.com...
  • Page 26: Troubleshooting

    1. Replace 4-AA batteries in receiver and/or remote Remote does not function 1. Battery is not installed or battery is power is control Astria.us.com 126750-01H...
  • Page 27 2. Inlet gas pressure is too low 2. Contact local propane/LP or natural gas com- pany 3. Thermopile leads disconnected or improperly 3. Reconnect leads to TP and TPTH terminals on connected control valve 4. Thermopile is defective 4. Replace thermopile 126750-01H Astria.us.com...
  • Page 28 3. Improper venting or excessive blockage 3. Have vent system inspected, including ter- mination cap. Remove any restrictions or obstruction 4. Excessive amounts of embers and pan mate- 4. Clear excess embers until a minimum gap of rial 1/2" remains under grate Astria.us.com 126750-01H...
  • Page 29: Wiring Diagram

    WIRING DIAGRAM 126750-01H Astria.us.com...
  • Page 30: Replacement Parts

    When contacting your dealer please have your model • Gas Type: Natural Gas Only and serial numbers of your fireplace ready. You can also visit our • Ignition: Electronic web site at Astria.us.com. • Manifold Pressure: 3.5" W.C. REPLACEMENT PARTS • Minimum Inlet Supply Pressure: 4.5" W.C.
  • Page 31: Accessories

    ACCESSORIES Purchase these appliance accessories from your local dealer. If they can not supply these accessories, contact IHP at Astria.us.com for referral information. You can also write to the address listed on the back Page of this manual. Only kits supplied by IHP shall be used in the installation of this appliance. Use of non-approved accessory/part kit(s) can result in poor performance and safety hazards.
  • Page 32: Parts

    PARTS MODELS RAPTURE36, RAPTURE42 AND RAPTURE50 CAT. NO. MODEL F0793 Rapture36 F0794 Rapture42 F0795 Rapture50 16/17 Astria.us.com 126750-01H...
  • Page 33 • F2862 Limit Switch 260º F • • J3942 Limit Switch 300º F • PARTS AVAILABLE NOT SHOWN J4103 Wire Harness • • • see Page 40 Firebrick Walls • • • ** Not a field replaceable part. 126750-01H Astria.us.com...
  • Page 34 PARTS MODULE MODELS GTA36TEN, GTA36TEP, GTA42TEN, GTA42TEP, GTA50TEN AND GTA50TEP Logs not shown for clarity Astria.us.com 126750-01H...
  • Page 35 J6813 CORD, EXTENSION, PIGTAIL (16") • • • • • • J6868 SWITCH, ROCKER ON/OFF/REMOTE • • • • • • RP125518-01 PAINT, TOUCH UP 88C • • • • • • ** Not a field replaceable part. 126750-01H Astria.us.com...
  • Page 36 Mosaic50M4 Rapture 50" Split Stacked Warm Red Masonry Firebrick Walls F0811 Mosaic50M5 Rapture 50" Split Herringbone Warm Red Masonry Firebrick Walls F0812 Mosaic50M4 Rapture 50" Split Stacked Ivory Masonry Firebrick Walls F0813 Mosaic50M5 Rapture 50" Split Herringbone Ivory Masonry Firebrick Walls Astria.us.com 126750-01H...
  • Page 37 • • • • J6047 RETAINER, REAR PANEL 36/42/50 • • • • • • J6050 RETAINER, REAR PANEL 36/42/50 • • • • • • J5563 ASSY, BRICK ASH BOX RED • • • • • • 126750-01H Astria.us.com...
  • Page 38 • • • • J6047 RETAINER, REAR PANEL 36/42/50 • • • • • • J6050 RETAINER, REAR PANEL 36/42/50 • • • • • • J5565 ASSY, BRICK ASH BOX IVORY • • • • • • Astria.us.com 126750-01H...
  • Page 39: Warranty

    IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.
  • Page 40 Astria.us.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Table of Contents