Advertisement

Quick Links

SC-A10 Manual
User
SC-A1
Advanced weighing equipment with ABS or INOX finish, backlit LCD display with 3 numeric display
fields and alphanumerical keyboard.
2017-02-14
COMPLETE USER MANUAL
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Fobitec SC-A10

  • Page 1 SC-A10 Manual User SC-A1 Advanced weighing equipment with ABS or INOX finish, backlit LCD display with 3 numeric display fields and alphanumerical keyboard. 2017-02-14 COMPLETE USER MANUAL - 1 -...
  • Page 2 Features Weight-Tare-Piece counter with possibility of options and add-ons. Keys exclusively for the classic weighing system, similar to previous units, in the line of SC10. Clear, intelligible weighing symbols for improved, more convenient reading of the data displayed. Printing of weight on the platform with large, notable size. Clock/Calendar fitted as standard.
  • Page 3: Table Of Contents

    INDEX 1 KEYBOARD ........................- 4 - 2 FUNCTIONS MENU ......................- 5 - 3 DISPLAY LCD ........................- 8 - 4 INSTRUCTIONS AND GENERAL OPERATION MODE ............- 9 - 4.1 Ordinary weighing (Net/gross tare, tare lock) ..............- 10 - 4.1.1 Quick zero: .........................
  • Page 4: Keyboard

    1 KEYBOARD NUM: Numeric keyboard C: Delete figure, number or literal. F: Validate figure, number, literal, option. F1: Totalize F2: Tares / Codes F3: Rapid Manual Tare/ Piece Counter F4: User Menu ON / OFF: FUN: INTRO: LEFT: DOWN: RIGHT: Turn ON / Tare Zero /...
  • Page 5: Functions Menu

    2 FUNCTIONS MENU To enter: F4 (The optional ones are shaded) Option Description Actions Code of weighing in progress. (0.. 255) -CODE- NUM to modify code (numeric or alphanumeric) C delete flashing digit. UP/DOWN to increase/decrease the numeric code. F2 to change between numeric and alphanumeric code.
  • Page 6 Grand Total. It shows the grand total of accumulated weighings and BIG.TOT Shows the accumulated weight the grand total accumulated weight. total since the last time its value INTRO to show the accumulated grand total. was reset. INTRO during scroll: Prints and deletes the accumulated grand total.
  • Page 7 LOW.BOW is exceeded. No -> The equipment waits for the pressing of INTRO key to initiate the process of weight sample. (It does not wait for INIT.T. even though the LOW.BOW is exceeded). Shows/Sets the clock and CLOCK RIGHT to access submenu. calendar.
  • Page 8: Display Lcd

    3 DISPLAY LCD Símbolos de pesaje Scroll Estamos pesando Estado batería Display 1 Unidades Peso sobre plataforma Modo Piezas Tipo de datos Unidades Display auxiliar 2 Display auxiliar 3 Peso tarado, códigos, datos, etc. Peso total (a totalizar, a dosificar, etc.) - 8 -...
  • Page 9: Instructions And General Operation Mode

    4 INSTRUCTIONS AND GENERAL OPERATION MODE When starting up the unit, the ON/OFF key can be pressed to carry out an initial test, showing all the display's digits and pilots. The equipment identifier is then displayed: Then, if the equipment has dead weight (units with weight module or digital cell communication), the counter value is shown the number of times the unit's metrological (weight) parameters have been modified.
  • Page 10: Ordinary Weighing (Net/Gross Tare, Tare Lock)

    Finally, a message (banner type) describing the different functions of the unit is displayed. Both the text of the banner displayed when starting up the unit and the headers and footers of the tickets can be defined by the user using the SENSODATA program.
  • Page 11: Quick Zero

    4.1.1 Quick zero: Whenever, without any weight on the platform, the unit shows a weight value other than zero. The zero should be manually corrected by pressing the B key. The machine can automatically reset at start-up enabling the INIT.Z option in the WEI.OPT.
  • Page 12: Quick Tare

    Most of the actions carried out by the display (tare, print ticket, start load Most of the actions carried out by the display (print ticket, start load or or discharge of dose, etc.) are associated with stable platform condition discharge, etc.) are associated with stable platform condition. (stable weight).
  • Page 13: Gross Weight/Net Weight

    4.1.4 Gross weight/net weight: With the unit tared, pressing the B key allows switching between net weight and gross weight on the display. To indicate that the weight shown on the display corresponds to gross, enable both the B pilot and the NET pilot: Tare is automatically disabled when all the weight is removed from the platform, deleting and re-displaying the gross weight: 4.1.5 Tare lock...
  • Page 14: Quick Manual Tare (*)

    The tare lock function is only available if initial zero option (INIT.Z) has been enabled in the WE.CTR programming submenu. 4.1.6 Quick Manual Tare (*): The system allows to define a value of quick manual tare. To do this without leaving the weight mode, you must press the F3 key (This option does not work if the piece- counting mode is enabled).
  • Page 15: Memorized Tares (*)

    (*) The F3 function key to enter manual tare is NOT available in the following cases: - If are activated any of the following options: limits, semaphore or any dosage (options available via the submenu APLICA of the programming menu) - If the mode Piece-Counter is activated (option available via the submenu option PIECES of the user menu) 4.2 Memorized Tares (*)
  • Page 16: Quick Selection Code

    With an active preset tare, pressing the T key does not swing between tare and locked tare, but allows to tare again the weight pressing it when desired, saving at the same time as the value of memorized tare associated with the number of tare active in that moment. From this point functionality will be restricted to the tare blocking section.
  • Page 17: Extended Accumulation And Totalisation Of Weighings

    4.4 Extended accumulation and totalisation of weighings The unit can account for weight (accumulate weighings), using the data to print a ticket per printer and/or label and/or send the weighing data through the serial communication ports (PORTS). The unit allows individual weighings (printing a ticket for each weighing) or multiple weighings (with several weighings in the same ticket and finalised with a total) to be done automatically (when detecting stable weight on the platform) or manually (by pressing the INTRO key when the unit displays stable weight).
  • Page 18 Start manual weighing by pressing the ENT key until the message -ACC- is shown in the display: In the display auxiliary 2 is shown the number of weight performed, in the display auxiliary 3 the subtotal of weight accumulated so far. If the unit is connected to a printer, and, for example, the code "100350"...
  • Page 19: Automatic Accumulation

    In order to carry out a new weighing and continue accumulating, remove the weight from the platform and place the new weight to accumulate on it; wait for the weight to be stable and then press the ENT key again. 4.4.2 Automatic accumulation Automatic accumulations do not require the INTRO key to be pressed for weighing;...
  • Page 20 If the unit is connected to a printer, the ticket will finish, as in the following example: ======================================== N.WEIGH. CODE TARE kg NET kg ======================================== HIERRO 1.538 0.216 HIERRO 0.000 0.252 COBRE 0.000 0.083 PLATA 0.252 0.081 ======================================== TOTAL WEIGHINGS TOTAL WEIGHT kg ======================================== 0.632...
  • Page 21: Piece Counter

    4.5 Piece counter The piece counting mode can be enabled entering in the option "PIECES" in the functions menu of the device. When the equipment is running in piece counting mode, the value displayed is the result of the division between the measured weight and unit weight of each piece.
  • Page 22: Units With Battery

    In it this ticket is indicated the unit weight of the pieces, the weight and number of pieces of each weighing and total of pieces totalised. Each time you change between weight / pieces (by pressing the F3 key), the corresponding ticket will automatically close.
  • Page 23 When accessing the -DSD- option from the functions menu, the equipment requests the number of ticket displaying by default the last finished ticket, for example: When we press [ F2 ] button, we can access to We can access to the Once inside the option –...
  • Page 24 *Electromagnetic susceptibility has been certified in tests conducted with field strength of 10 V/m, in accordance with new regulations. - 24 -...

Table of Contents