  • Page 1 FIRECLASS FC490ST Loop Service Tool From Software version 1.0 User Manual 120.515.079_FC-D-490ST-U Doc. version 2 17. March 2015...
  • Page 2 © Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland, 2015 Contents subject to change without notice. All rights to this documentation, including the contents of the online help, are reserved, in particular but not limited to the rights of copying, distribution and translation.
  • Page 3: Table Of Contents

    FIRECLASS FC490ST Contents Contents Guide through this manual .................... 5 Keywords and symbols ........................5 Helpful information ........................5 Who this guide is for ........................5 Introduction........................6 Key Functions and Features ......................6 Technical Specifications ......................6 2.2.1 Mechanical Specifications..................................6 2.2.2 Electrical Specifications ..................................6 2.2.3...
  • Page 4 Contents FIRECLASS FC490ST User Manual Doc. version 2...
  • Page 5: Guide Through This Manual

    FIRECLASS FC490ST 1 Guide through this manual Guide through this manual Keywords and symbols Helpful information This documentation uses special notations that you can use Choose a command via the menu for better orientation. Symbols in the margins indicate This documentation explains how you can warnings, infos or instructions.
  • Page 6: Introduction

    Tool + batteries: 0.5 kg keys’, F1, F2, F3 and F4. (The display format is shown in Fig. Materials: Power for the FC490ST is derived from 4 AA size nickel Top: FR ABS Dark Blue  metal hydride rechargeable batteries. It may be run from an...
  • Page 7: Environmental Specifications

    FIRECLASS FC490ST 2.2 Technical Specifications 2.2.3 Environmental Specifications 2.2.4 EMC Specifications The FC490ST meets the requirements of the EU EMC Parameter Value Directive 89/336/EEC. Operating Temperature 0°C to +45°C Storage Temperature 0°C to +50°C Relative Humidity 90% (non-condensing) Battery Disposal Should be disposed of in accordance with local ...
  • Page 8: Operating Instructions

    2 seconds when the FC490ST is switched on: How to Install/Replace the batteries: 1 Unscrew the two screws on the base of the FC490ST, using a cross-point screw driver, holding the battery compartment cover whilst removing it.
  • Page 9: Button Operation

    When the ancillary lead is removed, the detector will be able to commu- nicate. The FC490ST may be connected to an ancil-  lary device that is also connected to and pow- ered from the addressable loop. However, a ‘No Response’...
  • Page 10 3.4 Button Operation FIRECLASS FC490ST F1 scrolls left through the main menu options  F2 or F3 select the menu option displayed  F4 scrolls right through the main menu options  When an option is selected from the main menu, the dis- play uses the format shown in Fig.
  • Page 11: Functionality

    Having programmed an address, the FC490ST moves to the next unused sequential address. Press buttons F2 or F3 to choose ‘Select’ and the address If an address has already been used, the FC490ST indi- of the device is displayed (for example, address 4). cates:...
  • Page 12: Measure Temp

    4.1 ADDRESS PROGRAM FIRECLASS FC490ST 4.1.2 MEASURE TEMP Menu TEST R1: This feature measures temperature in degrees Celsius and PASS degrees Fahrenheit, but is only available on detectors which have a temperature sensing element, for example, Heat only, Optical & Heat and CO & Heat detectors. A typi-...
  • Page 13: Digital Inputs

    Tog - toggles between 0 and 1 for each digit The batteries must be charged using the mains adaptor  with its connecting lead plugged into the FC490ST DC IN Set - prompts the FC490ST to send an instruction to the  12V socket. addressable device Menu - to return to the main menu options ...
  • Page 14: 4.1.10 Ordering Information

    FC490ST to actuate a switch. Spare ancillary lead : 516.800.922  When a CPU reset is carried out, the FC490ST will start up Ancillary lead spare pins (bag of 10) : 516.800.924  as described in 3.2 “Password Protection”.
  • Page 15: Appendix

    FIRECLASS FC490ST 4 Appendix Appendix Additional Information 4.1.2 Device Type IDs 4.1.1 Menu Functions DESCRIPTION MODEL TYPE VALUE MAIN MENU ACTIONS Optical Smoke/Heat FC400PH, DISPLAY Detector FC460PH Address Program Read/Writes the address of the  Optical Smoke Detector FC400P, connected addressable device.
  • Page 16 Further information about FIRECLASS can be found on the Internet at  www.fireclass.net Company stamp...