Advertisement

Quick Links

VIBE FREESTANDING
INSTALLATION INSTRUCTIONS
IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER
INSTALLATION VIBE EN_BU_v2.indd 1
2018-10-18 4:18 PM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VIBE FREESTANDING and is the answer not in the manual?

Questions and answers

Summary of Contents for BainUltra VIBE FREESTANDING

  • Page 1 VIBE FREESTANDING INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION FOR THE INSTALLER AND THE OWNER INSTALLATION VIBE EN_BU_v2.indd 1 2018-10-18 4:18 PM...
  • Page 2: Table Of Contents

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 2 2018-10-18 4:18 PM...
  • Page 3 VIBE FREESTANDING INSTALLATION INSTRUCTIONS VIBE FREESTANDING www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. INSTALLATION VIBE EN_BU_v2.indd 3 2018-10-18 4:18 PM...
  • Page 4: Important Safety Instructions

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 4 2018-10-18 4:18 PM...
  • Page 5 • Once plumbing is fully installed and before beginning any other work, fill the ThermoMasseur with water to ® overflow level and wait 30 minutes. Check all plumbing hook-ups and bath for leaks. BainUltra is not responsible ® for any water damage caused by improper installation (see Warranty section in the Owner’ s Manual).
  • Page 6: Parts & Tools

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 6 2018-10-18 4:18 PM...
  • Page 7 VIBE FREESTANDING INSTALLATION INSTRUCTIONS PARTS & TOOLS REQUIRED STANDARD PARTS- FLOOR ANCHOR & ACCESSORIES DESCRIPTION Threaded anchor #10 X 1-1/2” Countersunk head screw STANDARD PARTS – THERMOMASSEUR ® DESCRIPTION Turbine MiaPlus Control ® MiaMulti Control (option) ® 15’ control cable PARTS &...
  • Page 8: Site Preparation

    ® ® dimensions of site before installation. If you do not already have the technical specifications, download it from the BainUltra ® Web site at: bainultra.com or call us at: 1 800 463-2187. 1 800 463.2187 Monday to Thursday from 8 a.m.
  • Page 9 VIBE FREESTANDING INSTALLATION INSTRUCTIONS SITE PREPARATION TURBINE - REMOTE INSTALLATION 1. A 1 ½ inch ID pipe has to run from the tub, back to the turbine location. This pipe can be PVC Tigerflex (spa hose) or rigid PVC or ABS 2.
  • Page 10: Installation With Access Under The Floor

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 10 2018-10-18 4:18 PM...
  • Page 11 VIBE FREESTANDING INSTALLATION INSTRUCTIONS INSTALLATION WITH ACCESS UNDER THE FLOOR PVC DRAIN PVC & BRASS DRAIN BRASS DRAIN www.bainultra.com Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents. INSTALLATION VIBE EN_BU_v2.indd 11...
  • Page 12: Installation

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 12 2018-10-18 4:18 PM...
  • Page 13: Installation Without Access Under The Floor

    NOTE : Please refer to the Cutting Template provided with your VIBE bath. However, if it is missing, please contact us at 1-800-463-2187 to order it. Available on our website at BainUltra.com. PLUMBING - ISLAND TUB DRAIN (ITD) INSTALLATION HELPFUL TIP: •...
  • Page 14: Plumbing

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 14 2018-10-18 4:18 PM...
  • Page 15: Installation

    VIBE FREESTANDING INSTALLATION INSTRUCTIONS INSTALLATION WITHOUT ACCESS UNDER THE FLOOR INSTALLATION DU BAIN HELPFUL TIPS: Measure & • Carefully place the tub on Align (2x) its side, on a blanket or a corrugated cardboard. • To easily manipulate the bathtub in a safe way...
  • Page 16 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 16 2018-10-18 4:18 PM...
  • Page 17: Remote Mounting Of Turbine

    VIBE FREESTANDING INSTALLATION INSTRUCTIONS REMOTE MOUNTING OF TURBINE TURBINE & GEYSAIR INSTALLATION (FOR THERMOMASSEUR ® GEYSAIR HOSE AND FLOW REGULATOR 1-1/2 I.D. PVC AIR INTAKE PIPE («TIGERFLEX ® » FLEXIBLE PVC) FLOW REGULATOR 1-1/2 I.D. ABS, PVC PIPE (RIGID or «TIGERFLEX») &...
  • Page 18 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 18 2018-10-18 4:18 PM...
  • Page 19: Electrical Connection (Thermomasseur)

    REMOTE MOUNTING OF TURBINE - ELECTRICAL CONNECTIONS (THERMOMASSEUR ® • See page 23 for electrical diagram GEYSAIR BACK FLOW PREVENTER EXTENSION CORD (For extra extension cord length, contact BainUltra to order) GEYSAIR CONNECTION Junction box TO GFCI Outlet Canada United States WARNING • For Geysair equipped baths using remote turbine installation (not mounted on the bath), grounding continuity ®...
  • Page 20: Electronic Controls

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 INSTALLATION VIBE EN_BU_v2.indd 20 2018-10-18 4:18 PM...
  • Page 21: Electrical Section

    VIBE FREESTANDING INSTALLATION INSTRUCTIONS ELECTRICAL SECTION ELECTRICAL CONNECTIONS FOR REMOTE MOUNTING OF TURBINE AND THERAPIES • See page 23 for electrical diagram Jonction Box (Canada) To GFCI OUTLET (United States) Inmix module Geysair To right LED A : Chromatherapy (LED) B: MiaPlus ®...
  • Page 22: Electrical Connections For Remote Mounting Of Therapies (Baths Without Air Jets)

    DOT Chromatherapy (LED) WARNING • VIBE freestanding bath cannot be drilled for faucet installation. Faucets must be freestanding or wall-mounted models. 1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada.
  • Page 23 VIBE FREESTANDING INSTALLATION INSTRUCTIONS ELECTRICAL SECTION ELECTRICAL DIAGRAM – 20A THERMOMASSEUR and 15A THERAPY ® 20A CIRCUIT 15A CIRCUIT 15A CIRCUIT NEUTRAL N L LOAD NEUTRAL N L LOAD NEUTRAL N L LOAD GROUND GROUND GROUND FAULT CIRCUIT FAULT CIRCUIT...
  • Page 24: Cutting Templates Of Electronic Controls

    1 800 463.2187 Monday to Thursday from 8 a.m. to 6 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Printed in Canada. Copyright © October 2018 BainUltra Inc. All rights reserved. 45200671 1 800 463.2187 Monday to Thursday from 8 a.m. to 8 p.m. (EST) . Friday from 8 a.m. to 5 p.m. (EST) Du lundi au jeudi, De 8 h à...

Table of Contents