Page 1
TagTemp-NFC-LCD OPERATION MANUAL V1.0x CE Mark This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. NOVUS AUTOMATION 1/13...
MECHANICAL INSTALATION Measurement Interval input). 2 hours max. (Models with digital TagTemp-NFC-LCD can be fastened in three ways: using screws, input). double-sided tape or with the frame. For screw fastening, use two M3x14 mm screws. See Fig. 01. 3.0 V (CR2450) lithium battery,...
The start of records may be immediate or by pressing the button In case of sensor error (sensor broken or shorted), "Err" will be displayed on the LCD display. If the TagTemp-NFC-LCD is logging when an error condition occurs, the value -99.9 will be recorded in The ending of the records can be one of the following (whichever the configured temperature unit.
• 5-minute interval between logs. 5.11 Digital Input LOGCHART-NFC APPLICATION A digital input is available on some models of TagTemp-NFC-LCD. It allows to record state changes, i.e., records the moment when the The LogChart-NFC is an app for ANDROID™ platform that allows the digital input changed from OFF (logic "0") to ON (logic "1") and vice-...
After the application has been started (see Fig. 06), just approach Device Info: Indicates specific information of TagTemp-NFC- • the smartphone to TagTemp-NFC-LCD this distance may vary for LCD. different devices, in the worst case it will be necessary to touch the Device Tag: Name configured by the user.
Enable digital input: with this option enabled, when the digital 9.2.4 Events and Occurrences Screen input is activated, TagTemp-NFC-LCD will record this occurrence to the memory. Use Fahrenheit degrees: when this option is enabled, the temperature unit of Celsius (default) is changed to Fahrenheit.
Page 7
TagTemp-NFC-LCD Alarm Events Log: TagTemp-NFC-LCD logs temperature to the memory whenever the temperature falls in or out the alarm state, so the user has the exact moment when a temperature has gone out or in the alarm state. One can see this functionality in Fig.
, you can share the obtained data, using sharing applications already installed on the smartphone as well the option to send data to NOVUS Cloud (requires the creation of an account in NOVUS Cloud) and also the option to send to an FTP server (requires an active FTP server).
Page 9
: Hire an account in the NOVUS • Cloud to store the TagTemp-NFC-LCD data. Enter your login Preview options: option to choose the start and end date for the credentials in the Login and Password fields to send the data.
Fig. 30 – Configuration Screen The configuration of the TagTemp-NFC-LCD is distributed in several screens. The "General" screen contains the following information: Information: Shows information about the device, such as: Model, Serial Number, Firmware Version, Memory Capacity, Log Status, and Battery Charge.
Page 11
Reset the Minimum and Maximum: This button resets the device's minimum and maximum values. TagTemp-NFC-LCD must be in the NFC reader field for the action to be performed. Download logs: This option allows the data in the device memory to be transferred to the application.
Page 12
TagTemp-NFC-LCD Downloading Data 10.4.1 Sharing and processing data When you select the "Download" option in the application start After completing the download, a screen will be displayed with the screen, another screen with the following options will be displayed: downloaded data and these are presented in two forms: in graph form and table form.
Events: This tab shows all alarm events recorded to the Reports: There are four report templates available, each of them has TagTemp-NFC-LCD memory, with information such as date and configurable parameters that can be changed before generating the time, condition (entering, exiting alarm), value, etc.
Need help?
Do you have a question about the TagTemp-NFC-LCD and is the answer not in the manual?
Questions and answers