Electrostatic Discharge (Esd); Table 3. Power Supply Requirements; Table 4. Esd Specifications - Sierra Wireless AirPrime SL8084T Integration Manual

Table of Contents

Advertisement

Hardware Integration Guide
Mode
Band
EDGE
850
900
1800
1900
a.
Includes USB bus current.
b.
Peak consumption averaged over 100µs.
c.
Current consumption increases by 50mA with a 6dB return loss-based load-pull.
d.
GSM mode peak current increases to 2.2A (from nominal 1.6–1.7A) with 6dB return loss-based load-pull.
The host device must provide power to the AirPrime soldered-down module over pins 42 and 44
(VCC_3V6) as detailed in the following table.
Table 3.
Power Supply Requirements
Requirement Type
Power Supply
Voltage Range (V
MIN
Current (instantaneous (≤5ms))
Current (continuous)
Note:
The host must provide safe and continuous power to the module; the module does NOT have
protection circuits to guard against electrical overstress.
2.2.

Electrostatic Discharge (ESD)

The host device must provide adequate ESD protection on digital circuits and antenna ports as
detailed in the following table.
Note:
The level of protection required depends on the application.
Table 4.
ESD Specifications
Category
Operational
Non-operational
Signals
4112719
Tx
Current (at 3.6V)
Power
Peak
b
(mA)
+27
860
+27
960
+26
740
+26
660
Value
3.6V (nominal)
– V
)
3.3V – 4.3V
MAX
3A
700mA
Connection
RF port (antenna launch
and RF connector)
Host connector interface
USIM connector
Other host signals
Rev 2.1
Average (mA)
170
260
340
180
280
360
150
230
290
150
220
270
Specification
IEC-61000-4-2 — Level (Electrostatic Discharge Immunity
Test)
Unless otherwise specified:
JESD22-A114-B +/- 2kV Human Body Model
JESD22-C101 +/- 300V Charged Device
ESD protection is highly recommended at the point where
the USIM contacts are exposed, and for any other signals
that would be subjected to ESD by the user.
Power Interface
Conditions
400
Class 12
430
50Ω
340
300
January 07, 2013
10

Advertisement

Table of Contents
loading

Table of Contents