GENERAL INSTRUCTIONS
1. DO
NOT ATTEMPT
TO
REPAIR OR
RECALIBRATE
CONTROL.
Controls
requiring service should
be returned to
RESEARCH
PRODUCTS
CORPORA-
TION, Poynette, WI 53955.
2. Control must be installed using 24 volts!
3. Make sure no bare wires are exposed or
insulation
damaged.
Insulation
on wire
should extend to head of binding screws.
4. Make sure all splices are mechanically and
electrically secure.
5. To remove dirt or other foreign matter from
nylon ribbon and control interior, dust lightly
with a fine, soft brush.
LOCATION
1. Locate
on inside
wall
of living
area
approximately
5' above floor, or in the
furnace return air plenum or duct.
2. Do not locate control in the direct path of
furnace discharge air or drafts from open
doors and windows.
3. Do not install where operation might be
affected
by lamps,
sunlight,
fireplace
registers, radiators, concealed air ducts and
pipes, or room occupants.
4. The basic rules for location of thermostats
also apply to humidistats.
1. Power
The Model 360 is prewired
internally and
equipped with a 120 VAG cord and plug.
2. Humidity Control
Locate the Aprilaire Humidistat on an easily
accessible inside wall in the living area at least
5' away from the discharge grille. Be sure it's
installed in an area not closed
off from the
grille.
1. Open saddle valve completely and plug in
power cord.
2. Advance humidistat to call for humidity and
check for waterflow out the drain.
3. Reduce humidistat to recommended level.