Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions Content General ..........................4 General information ...........................4 Intended use ..............................4 Misuse ...............................4 Regulations and standards ........................4 Health and safety instructions ........................4 Warning against your own conversions and changes: For safety reasons, you must not convert or modify the vessel yourself.
Intended use The Cetetherm AquaTank is a hot water storage vessel and is used to store potable water for normal use in potable water supply systems and is suitable for group or central drinking water supplies. Using the equipment as intended also includes following these operating instructions, the maintenance conditions and design data specified.
Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions The vessel must be protected against unauthorised operation. Contact with hot parts of the cylinder can cause serious burns. Avoid any contact with hot parts of the vessel. Installer will have to adapt safety system to local rules and evolution of these rules : In France diameter of safety valve must correspond to diameter of cold water inlet pipe : 2”.
CM737 Consignes d'exploitation 2 Installation Please safeguard the storage tank during unloading and transportation against tilting. Do not use inappropriate transport equipment and avoid damages by crushes and whams. The vessel is very heavy and has a high centre of gravity. Please transport it carefully and only use suitable equipment, e.g.
Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions 3 Commissioning & Operation • When charging the vessel with the water for the first time, make sure that all screw connections are properly tightened, tighten any loose connections with a suitable tool and make sure that all seals are firmly seated and leak-tight, particularly the flange seal on the tank.
AquaTank 316Ti is in article 4.3 according to PED 2014/68/EU. AquaTank 316Ti HC could be not in article 4.3 according to PED 2014/68/EU if used with water above 110°C inside coils. Please check so available detailed drawing to get exact PED classification The DECLARATION of SUPPLIER is directly attached to the delivered vessel.
Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions 5 Dimensions and technical data AQATANK 316 Ti Energy efficiency class according to European Union rule No. 814/2013 and No. 812/2013...
Non-payment will lead to all operational warranties covering the delivered equipment being terminated. Spare parts Only replace any defective part with the original spare part. Please contact your local Cetetherm agency. How to contact Cetetherm Our contact details are updated on our website...
Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions 8 Connection of 1 tank/2 tanks to a Tap Water System DESIGNATION DESIGNATION Primary inlet Heat Exchanger (PHE) Primary Outlet Primary pump (single/double) Setting valve Charging Pump (1 or 2) Cold water inlet...
CM737 Consignes d'exploitation 9 Neodul-Installation 1. Put fleece plugs into drilled holes. 2. Connect insulation segments together and close hooking closure step by step 3. Push in left part of hooking closure → Right part slips over left part of hooking closure.
Page 15
Manual AQUATANK 316Ti/316 Ti HC Installation and maintenance instructions 4. Insert top insulation after mounting insulation segments.