Labgear PSM114E/S Installation Instructions

Labgear PSM114E/S Installation Instructions

Erp compliant in line power supply, 12vdc 100ma power supply with type-f connections

Advertisement

Quick Links

PSM114E/S - 12VDC 100mA power supply with Type-F connections
Applications
The PSM114E/S is a 12VDC regulated power supply ideal
for powering any masthead amplifier, or a number of
masthead amplifiers in cascade, providing the total
current demand is not more than 100mA.
ErP Compliance
The power supply complies with the ErP (Energy Related
Products) Directive. This means that when there is no load
the power used is less than 0.3W and the energy efficiency
in use complies with the directive.
Mounting and Ventilation
Fix the unit to the wall, skirting board, mounting board or
similar hard surface. A ventilation gap of at least 25mm
should be left around the front and sides of the unit.
Do not leave the power unit resting on a carpet.
Do not install the power unit where it may become smothered with curtains or other fabrics.
When installing the power unit in a roof space ensure that it will not become buried in thermal insulation materials.
Signal connections are made to the coaxial sockets on the right-hand side of the power unit. Good quality coaxial
cable to EN50117-2 must be used. Labgear recommend the use of CAI "benched marked" cable.
The down lead from the masthead amplifier must be connected to the socket marked "AMP".
The signal output from the socket marked "TV" is connected to the receiving installation
(satellite receiver, VCR, TV, etc.) or to the input of the cabled distribution system.
Connections
A connection to the PSM114E/S is made using Type-f (male) connectors. The use of high quality crimp connectors
is preferred. F type connectors should always be tightened with a spanner. Leaving them finger tight may result in
unwanted signal ingress or leakage, as well as suck-outs in the frequency response.
Mains Power Connection
The PSM114E/S power unit is fitted with a moulded mains plug and may be plugged directly into a socket outlet.
Alternatively the plug may be cut off and the power unit wired into a fused connection unit, fitted with an approved
3A fuse to BS1362. The PSM114E/S is of a class 2 construction and does not require a protective earth connection.
If the power unit is not connected to the mains using the fused plug supplied or a fused connection unit, it must be
protected by means of a fuse or MCB at the distribution board of rating no more than 6A.
Short Circuit Protection
The PSM114E/S has automatic short circuit and overload protection and will cut out automatically when either is
detected. Reset is automatic when the problem is resolved.
General Safety Notes
To avoid risk of electric shock during installation we recommend that the power unit and all associated TV receivers,
etc. are isolated from the mains until the installation is complete.
Fixed wiring for electrical supply to these products should be carried out in accordance with BS7671
(IEE Wiring Regulations).
Distribution systems supplying signals to more than one household should comply with the safety requirements of
BS EN50083-1. This requires the system to be earth bonded or the use of isolated outlets.
ErP Compliant In Line Power Supply
Installation Instructions

Advertisement

loading

Summary of Contents for Labgear PSM114E/S

  • Page 1 Mains Power Connection The PSM114E/S power unit is fitted with a moulded mains plug and may be plugged directly into a socket outlet. Alternatively the plug may be cut off and the power unit wired into a fused connection unit, fitted with an approved 3A fuse to BS1362.
  • Page 2 This does affect your statutory rights. Labgear reserve the right to modify their designs or specifications, In the light of future developments, without prior notice. Performance figures quoted are typical and subject...
  • Page 3 Labgear/Screwfix 6/01/14 PSM114E/S 2pp 148.5 x 210mm Raised Red Logo...