TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Compressor will not run
Motor hums but cannot run
or runs slowly
Fuses blow/circuit breaker
trips repeatedly
Thermal overload protector
cuts out repeatedly
Air tank pressure drops when
compressor shuts off
Compressor runs continuously
1.
Unit is plugged into extension cord
2.
No electrical power
3.
Blown fuse
4.
Breaker open
5.
Thermal overload open
6.
Pressure switch defective
7.
Shorted or open motor winding
1. Low voltage
2.
Unit is plugged into extension cord
3.
Shorted or open motor winding
4.
Defective check valve or unloader
1.
Incorrect size fuse, circuit overloaded
2.
Unit is plugged into extension cord
3.
Defective check valve or unloader
1.
Low voltage
2.
Clogged air filter
3.
Lack of proper ventilation/room
temperature too high
4.
Unit is plugged into extension cord
1.
Loose connections (fittings,
tubing,
etc.)
2.
Loose drain valve
3.
Check valve leaking
4.
Check tank for cracks or pin holes
1.
Excessive water in air tank
2.
High humidity
1.
Defective pressure switch
2.
Excessive air
usage
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
1.
2.
3.
1.
2.
3.
4.
1.
2.
3.
Remove extension cord or use larger gauge
extension cord
Turn on pressure switch? Plugged in? Check fuse/
breaker or motor overload
Replace blown fuse
Reset, determining why problem happened
Unplug and allow motor to cool before trying to
restart
Replace
Replace motor
Check with voltmeter
Remove extension cord or use larger gauge
extension cord
Replace motor
Replace or repair
Check for proper fuse, use time-delay fuse.
Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit
Remove extension cord or use larger gauge
extension cord
Replace or repair
Check with voltmeter
Clean filter (see Maintenance section)
Move compressor to well ventilated area
Remove extension cord or use larger gauge
extension cord
Check all connections with soap and water solution
and tighten
Tighten
Disassemble check valve assembly, clean or replace
A.DANGER
Do not disassemble check valve
with air in tank;
bleed
tank first.
4
.
Replace tank., Never repair a damaged tank.
1.
Drain tank
2.
Move to area of less
humidity;
use air line filter
1.
Replace switch
2.
Decrease air usage; compressor not large enough for
a requirement
3.
Air leaks
3.
Check all connections with soap and water
Compressor vibrates
Loose mounting bolts
Tighten
---------~------------------
Air output lower than normal
1.
Broken inlet valves
1.
Have authorized service representative repair unit
2.
Intake filter dirty
2.
Clean or replace intake filter
3.
Connections leaking
3.
Tighten connections
,
12