Download Print this page

Sebury W2 User Manual

Waterproof standalone proximity reader

Advertisement

Quick Links

Attachment: Advanced Application
1. W2 operating as a Controller
In this mode the W2 supports a Wiegand 26 bit input so an external Wiegand device
with a 26 bit output can be connected to the Wiegand input terminals on the W2. Either
an ID card reader (125 KHZ) or an IC card reader (13.56MHZ) can be connected to the
W2. Cards are required to be added at the external reader, except where an external
EM reader is used, in this case cards can be added at either reader or controller. See
figure 1
W2 controller
J1
D0
Green
D1
White
Grey
ALARM-
W2 Quick reference Programming Guide
OPEN
Yellow
D_IN
Brown
Function description
Choose from the relevant function below and input
+12V
Red
*
888888
#
GND
Black
Enter the programming mode
then you can do the programming
VSS
Blue
(888888 is the default factory master code)
Purple
L-
To exit the programming mode
*
L+
Orange
ALARM+
Note: that to undertake the following programming the master user must
enter into the programming mode
0 New code # Repeat New code #
Change the master code
(Code must be 6-8 digit numbers.)
1
Read Card
#
Add card user
( Can add card continuously)
2. W2 operating as a Wiegand Output Reader
2
Read Card
#
In this mode the W2 supports a Wiegand 26 bit output so the Wiegand data lines can be
Delete card user
( Can delete card continuously)
connected to any controller which supports a Wiegand 26 bit input. See figure 2
To Unlock the door
To Unlock the door
Read user card
D0
D1
+12V
GND
Controller
Power
Powerful supply
wiegand reader
DC12V/3A
+
+
-
Em card
GND
Ic card
-
+12V
HID card
D1
D0
reader plug
Controller with wiegand 26 input
-
+
figure 2
Alarm
door detecting switch
Exit button
3. Two W2 units interconnected for a single door
-
In this mode two W2 units are used for a single door, one for entry and the other for exit.
Lock
Either device acts as the controller and reader at the same time. Users can be
+
enrolled in either of the devices. In this mode the user capacity for one door can be
up to 20000. The setting of the two W2 units must be the same including the master
code. See figure 3
Figure 1
4. Two W2 units interconnected & interlocked for 2 doors
In this mode two W2 units are used for two doors which are then interconnected and
interlocked. In this mode the doors can be interlocked so that when door 1 is open, door
2 cannot be opened, and vice versa. The interlocked function is mainly used in banks,
prisons, and other places where a higher level of security is required. See figure 4
.7.
.8.
J1
Power
outdoor
indoor
DC12V/3A
J1
Green
D0
+
-
J1
White
D1
Green
D0
Green
Grey
White
ALARM-
D1
White
-
Grey
Yellow
OPEN
ALARM-
Grey
+
Yellow
OPEN
Yellow
Brown
D_IN
Alarm
Brown
D_IN
Brown
Red
+12V
Exit button
door detecting switch
Red
+12V
Red
Black
GND
GND
Black
Black
Blue
VSS
VSS
Blue
Blue
Purple
L-
L-
Purple
-
Purple
Lock
Orange
L+
L+
Orange
+
Orange
ALARM+
ALARM+
W2
W2 controller 1
W2 controller 2
figure 3
W2 controller 2
W2 controller 1
Power
DC12V/3A
J1
Door 1
Door 2
J1
+
-
D0
Green
Green
D1
White
White
ALARM-
Grey
-
-
Grey
+
+
OPEN
Yellow
Yellow
Alarm 1
Alarm 2
D_IN
Brown
Brown
door detecting switch 1
Exit button 1
Exit button 2
door detecting switch 2
+12V
Red
Red
GND
Black
Black
VSS
Blue
Blue
L-
Purple
-
-
Purple
Lock 1
Lock 2
L+
Orange
+
+
Orange
ALARM+
figure 4
.9.
5. Anti-submarine function for single door (3 1 #)
The connection diagram is as figure 1. Install one Wiegand reader (or a W2 without user
information as reader) outside the door, connecting to one W2-Controller inside the
door, which acts as the Anti-submarine Master unit. of the two devices, they build up an
anti-submarine system for single door. The operation and function is as below:
D0
D1
5.1 Set the needed function and enroll the User Cards on the inside W2 - Anti-
ALARM-
submarine Master unit.
OPEN
5.2 With the valid user card, the user can only enter the door from the outside reader,
D_IN
and exit from the inside W2 Controller. On the other hand, without entering record from
+12V
the reader, the user can't exit from the controller inside, also, the user can't enter in
GND
twice without the first exit record , and vice versa.
VSS
L-
6. Anti-submarine function for 2 doors
L+
The connection diagram is as Figure 4. Door 1 with one W2, and Door 2 with one W2,
ALARM+
set one W2 on Door 1 as the Anti-submarine Auxiliary unit (3
2 # ), and set the other
W2 on Door 2 as the Anti-submarine Master unit(3
1
# ). They build up a two doors
anti-submarine system, which is normally used for parking lot......etc.
The operation and function is as below:
6.1 Set the needed function and enroll the User Cards from W2 - Anti-submarine Master
unit on Door 2.
6.2 With the valid user card, the user can only enter in from Door 1, and exit from Door 2.
On the other hand, without entering record from the Auxiliary unit, the user can't exit
from the Master unit or Auxiliary unit , also, the user can't enter in twice without the first
D0
exit record , and vice versa.
D1
ALARM-
OPEN
D_IN
+12V
GND
VSS
L-
L+
ALARM+
.10.
W2
Waterproof
Standalone Proximity Reader
User manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the W2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sebury W2

  • Page 1 (888888 is the default factory master code) Purple Power In this mode two W2 units are used for a single door, one for entry and the other for exit. On the other hand, without entering record from the Auxiliary unit, the user can't exit DC12V/3A...
  • Page 2 Delete ca rd Cards can be deleted continuously. magnetic contact of the lock, if the door is forced open, or if the door is opened after Please ensure that all the above contents are correct. If any are missing, please notify the supplier of the W2. D_IN...
  • Page 3 SELF INSTALL - NEED TECHNICAL ASSISTANCE? OPTION 1: DIRECT WITH THE SERVICE DESK – QUICKEST AND MOST EFFECTIVE METHOD Submit your enquiry direct with the service desk at – service@automaticsolutions.com.au The service desk has the most experienced staff in Australia to help with your problem but they need your help. ...