Water Control PS-5 Troubleshooting And Maintenance Manual

Reverse osmosis drinking water system

Advertisement

Quick Links

PS-5 Reverse Osmosis Drinking Water System
Maintenance
-
4 stage membrane/filter cartridge should be changed every 1-2 years
o Decrease in system production and increased TDS output are signs the cartridge needs
to be changed
-
Inline carbon filter
o Should be changed every 6-12 months

Troubleshooting

-
#1 Problem – Water Leaking Out of Air Gap
o System is doing what it is designed to do
o Causes
Troubleshooting/Maintenance
Air gap is typically required by code
Creates separation between RO unit (backflow prevention)
Water that backs up in the drain line goes out of air gap rather than back to RO
unit.
Installation errors
Is the drain saddle installed nice and straight?
Does the drain tubing that connects from the air gap on the faucet to
the drain saddle have any loops or dips in the line?
o Should be installed as short and straight as possible in a
downward path.
Obstruction in the drain tubing between air gap faucet and drain saddle
Disconnect the tubing and blow through it in either direction to make
sure it is clear.
1931 205th Ave NW · Ramsey, MN 55303
Phone: 866-405-1268 · Fax: 763-427-5665
www.watercontrolinc.com

Advertisement

loading

Summary of Contents for Water Control PS-5

  • Page 1: Troubleshooting

    PS-5 Reverse Osmosis Drinking Water System Troubleshooting/Maintenance Maintenance 4 stage membrane/filter cartridge should be changed every 1-2 years o Decrease in system production and increased TDS output are signs the cartridge needs to be changed Inline carbon filter o Should be changed every 6-12 months Troubleshooting #1 Problem –...
  • Page 2 PS-5 Reverse Osmosis Drinking Water System Troubleshooting/Maintenance A Noisy Air Gap Faucet This can be caused by the air gap faucet, the location of the drain saddle, a restriction in the drain tube, or water pressure in excess of 85 psi.
  • Page 3 Disconnect membrane vessel from frame. Open feed water slowly. If water does not come out of fitting where membrane vessel was connected, ASOV needs to be replaced. On a PS-5 the water should come out of the fitting at the top.
  • Page 4 PS-5 Reverse Osmosis Drinking Water System Troubleshooting/Maintenance Is storage tank operating correctly? Open the faucet until the water stops flowing in a stream. Try to pick up storage tank. If it is heavy like a bowling ball, it may not be working correctly. If it is light like a basketball, make sure that the tank valve is open.