A crawl space dehumidifier like this shall be dimensioned for 1.5 to 2 air exchanges per hour, which makes CTR STD-TT suitable for crawl spaces with a volume of up to 180 150m For the user's comfort, for control and monitoring of the dehumidifier's operation and function, the CTR STD-TT is developed for use with Homevision®...
Contact the supplier for further information. 21. The dehumidifier must not be used with accessories other than those described in this manual or approved by Corroventa Avfuktning AB. Contact the supplier of this dehumidifier for further advice on the safety and use of the product.
The adsorption principle thus provides effective dehumidification at temperatures well below freezing. The fixed desiccant that is used in CTR STD-TT is silica gel, which can be regenerated an almost unlimited number of times. Silica gel is a crystal with many small microscopic pores giving the crystal's walls a massive surface area.
Note: If this has not already been done, consider obtaining an Installation kit TT Multi, for a simple, energy efficient and well-functioning installation. Overview, controls and connections The images below show CTR STD-TT with its external parts and controls. Dry air connector Wet air connector...
Page 11
Note: Installation kit TT Multi contains 16 nozzles but only 12 to 14 will be used with CTR STD-TT. Do not forget to install covers or seal the dry air duct's lower exit in another way, as per the example in the right-hand image below.
Note that any electrical installations carried out in connection with this work must be done by a qualified electrician in accordance with local and national regulations. CTR STD-TT must be connected to an earthed, single phase 230VAC/50 Hz socket with a maximum 16A fuse. An earth-fault breaker is recommended with consideration of the environment in the crawl space The following instructions are based on using the TT Multi installation kit.
Accessories The following parts are available as accessories and consumables for CTR STD-TT: Part number Designation 1000926 Filters Fault tracing Fault symptom Probable cause Actions Connection of control The control unit has already Restart the control unit by disconnecting panel failed at instal- been powered for longer the current to it for a couple of minutes.
Weight, kg *A crawl space dehumidifier like this shall be dimensioned for 1.5 to 2 air exchanges per hour, which makes CTR STD-TT suitable for crawl spaces with a volume of up to 150 m **Sound level varies depending on installation.