Ⅰ. INTRODUCTION
CLEARFIL MAJESTY ES-2 is a light-cure, radiopaque restorative material
which provides accurate color matching, high polishability and excellent
physical properties, making it ideal for both anterior and posterior restorations. It
is formulated with optimal viscosity, assuring easy handling and placement. It is
packaged in traditional syringes or Pre-loaded tips (PLTs).
The "lightness/ value"- based unique shade taking system of the CLEARFIL
MAJESTY ES-2 Shade guide provides shade taking options for single (Classic)
Layering method Shade category
and dual-(Premium) shade layering for highly esthetic restorations.
Single-shade
Ⅱ. INDICATIONS
Dual-shade
CLEARFIL MAJESTY ES-2 is indicated for the following restorative
applications:
[1] Direct restorations for all cavity classes in anterior and posterior teeth
[2] Direct veneers
[3] Correction of tooth position and tooth shape (e.g. diastema closure, dwarfed
tooth, etc.)
2. Components
[4] Intraoral repairs of fractured restorations
Main contents
Ⅲ. CONTRAINDICATIONS
Patients with a history of hypersensitivity to methacrylate monomers 
Ⅳ. INCOMPATIBILITIES
Do not use eugenol containing materials for pulp protection or temporary
sealing since the eugenol can retard the curing process.  
Ⅴ. PRECAUTIONS
1. Safety precautions
3. Ingredients
1. This product contains substances that may cause allergic reactions. Avoid
Principal ingredients:
• Silanated barium glass filler
use of the product in patients with known allergies to methacrylate monomers
or any other components. 
• Pre-polymerized organic filler
• Bisphenol A diglycidylmethacrylate (Bis-GMA)
2. If the patient demonstrates a hypersensitivity reaction, such as rash, eczema,
features of inflammation, ulcer, swelling, itching or numbness, discontinue
• Hydrophobic aromatic dimethacrylate
use of the product and seek medical attention. 
• dl-Camphorquinone
3. Wear gloves or take other appropriate protective measures to prevent the
occurrence of hypersensitivity that may result from contact with methacrylate
[NOTE] 
monomers or any other components. 
4. Use caution to prevent the product from coming in contact with the skin or
getting into the eye. Before using the product, cover the patient's eyes with a
towel to protect them in the event of splashing material. 

VII. CLINICAL PROCEDURES

Shade taking and restorative technique

5. If the product comes in contact with human body tissues, take the following
actions:
Shade presentation in the shade guide: Classic shades except A6 are
<If the product gets in the eye>
arranged in the shade taking tabs as described below in the "Single-shade
Immediately wash the eye with copious amounts of water and consult a
Technique" and "Dual-shade Technique".
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
Translucent, Premium Enamel, Premium Dentin and A6 shades are arranged
physician.
<If the product comes in contact with the skin or the oral mucosa>
in the tabs marked T, E-1, E-2, D-1 and D-2.
in the tabs marked T, E-1, E-2, D-1 and D-2.
Immediately wipe the area with a cotton pellet or a gauze moistened with
alcohol, and rinse with copious amounts of water. 

1. Single-shade Technique (Classic system)

1. Single-shade Technique (Classic system)
1. Single-shade Technique (Classic system)
Step 1:
6. Use caution to prevent the patient from accidentally swallowing the product.
7. Syringe : Avoid sharing the same paste among different patients to prevent
cross- contamination. Dispense the paste onto a mixing pad before use. Do
not try to apply it directly from the syringe onto the patient's tooth.
8. PLT : Single- use only. Do not reuse a tip to prevent cross- contamination.
  
Discard it after use and disinfect the dispenser according to its instructions for
use.
2. Handling and manipulation precautions
【CLEARFIL MAJESTY ES-2】
1. The product must not be used for any purposes other than specified in
[II.INDICATIONS].
Step 2:
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
Pull out the chosen tab from the holder and select the corresponding shade.
2. The use of this product is restricted to licensed dental professionals.
3. Use a pulp capping agent in a cavity close to the pulp or in the event of
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
For example, if A2 tab is chosen, the shade D2, A2 or C1 can be selected as
shown below.
accidental pulp exposure.
4. Use a rubber dam to prevent contamination and to control moisture.
     
            
5. Do not use the product in conjunction with other composite materials. The
            
mixed materials may cause a change in physical properties, including a
possible decrease, from the expected results.
6. The paste should be used immediately after being dispensed from the
syringe or the tip. If the paste is to be left for a time before use, it should be

2. Dual-shade Technique (Premium system)

2. Dual-shade Technique (Premium system)
2. Dual-shade Technique (Premium system)
2. Dual-shade Technique (Premium system)
2. Dual-shade Technique (Premium system)
covered with a light-blocking plate.
7. When using a PLT, use the dispenser with slow and steady pressure.
Excessive force is not necessary.
8. When using the shade guide, take the following precautions to prevent cross-
contamination.
• Cover the entire shade guide with a disposable barrier (e.g. a poly bag) to
prevent saliva and blood contamination.
• Disinfect before and after use by wiping it thoroughly with an absorbent
cotton moistened with alcohol.
【Dental light-curing unit】
1. Do not look directly at the light source. Protective glasses are recommended.
2. Low light intensity causes poor adhesion. Check the lamp for service life and
the dental curing light guide tip for contamination. It is advisable to check the
dental curing light intensity using an appropriate light evaluating device at
appropriate intervals.
3. The emitting tip of the dental curing unit should be held as near and vertical
to the resin surface as possible. If a large resin surface is to be light-cured, it
A. Standard procedure Ⅰ (Indications [1] to [3])
is advisable to divide the area into several sections and light-cure each
section separately. 
[1] Direct restorations for all cavity classes in anterior and posterior teeth
[2] Direct veneers
4. Check the conditions required to cure the paste by referring to the light-curing
times listed in these instructions for use before using the product. 
[3] Correction of tooth position and tooth shape (e.g. diastema closure,
3. Storage precautions

A-1. Shade taking

1. The product must be used by the expiration date indicated on the package.
2. The product and shade guide must be stored at 2-25°C/ 36-77°F when not in
use.
3. When the product is stored in the refrigerator, it should be left at room
temperature for more than 15 minutes before each use. Failure to do this
might cause breakage of the syringe or the tip. 
A-2. Isolation and Moisture control
4. The product and shade guide must be kept away from extreme heat or direct
sunlight.
5. After the paste has been dispensed, the syringe should be capped securely
as soon as possible to prevent hardening by ambient light of the material,
and to prevent foreign matter from entering the syringe.

A-3. Cavity preparations

6. The product must be stored in a proper place where only dental practitioners
can access.
A-4. Pulp protection

VI. SHADES SYSTEM AND COMPONENTS

1. Shades
CLEARFIL MAJESTY ES-2 is available in the following 18 shades of Classic,
14 shades of Premium and 4 shades of Translucent:

A-5. Tooth surface treatment and bonding

1) Classic: XW, W, A1, A2, A3, A3.5, A4, A6,
B1, B2, B3, B4, C1, C2, C3, C4, D2, D3
2) Premium
A-6. Dispensing of the paste
-Enamel: XWE, WE, A1E, A2E, A3E, A3.5E, A4E
-Dentin : XWD, WD, A1D, A2D, A3D, A3.5D, A4D
3) Translucent; Clear, Amber, Blue, Gray
*A6, A3D, A3.5D and A4D are opaque shades.
6-2. PLT : Insert a PLT into the dispenser barrel and extrude the paste into
the cavity according to the instructions for use of the dispenser .
[CAUTION]
Use the dispenser with a slow and steady pressure. Excessive force
is not necessary. Discard the tip after use.

A-7. Placement and light-curing of CLEARFIL MAJESTY ES-2

7-1. The application of a flowable composite resin or a opaque resin (e.g.
Shades are arranged according to the "lightness/ value" and recommended
CLEARFIL ST OPAQUER) to the cavity as an initial layer is optional.
layering method.
When adapting it, Refer to its instructions for use.
Classic shades are designed for single-shade layering and Premium
7-2. Place the chosen shade of the paste into the cavity and light-cure with
shades are designed for a dual-shade layering method. Combination of
a dental curing unit. Considering the depth of cure, incremental curing
Premium A shades covers 3 Classic (VITA) shades.
may be required. Refer to the following table for the relationship
between curing time and depth of cure with a visible light source.
High
Lightness/ Value
Low
Table: Relationship between curing time and depth of cure for type of light
Shade
source.
Classic
XW W B1 A1 B2 D2 A2 C1 C2 A3 D3 B3 A3.5 B4 C3 A4
C4
Enamel
XWE WE
A1E
A2E
A3E
A3.5E
A4E
Premium
Dentin
XWD WD
A1D
A2D
A3D
A3.5D
A4D
Type of light source
(Light intensity)
[NOTE]
Translucent shades can be used for fine characterization of the
High-intensity BLUE LED*
restoration. A6 has the lowest lightness in Classic shades.
(More than1500 mW/cm
Middle-intensity BLUE LED*
(1100-1400 mW/cm
Low-intensity BLUE LED*
• CLEARFIL MAJESTY ES-2
(800-1000 mW/cm
Accessories
High-intensity Halogen lamp
• Shade guide (All shades described above)
(More than 800 mW/cm
• Shade guide compact (Classic shades except A6)
Low-intensity Halogen lamp
(400-700 mW/cm
Please see the outside of the package for detailed contents and quantity of
The effective wavelength range of each dental curing unit must be 400 - 515 nm.
each component.
*Peak of emission spectrum: 450 - 480 nm

A-8. Finishing

Contour the restoration and adjust the occlusion using a fine diamond
point. Polish with silicon rubber points or polishing discs in the usual
manner.
B. Standard procedure Ⅱ (Indications [4])
[4] Intraoral repairs of fractured restorations
B-1. Shade taking
The total amount of filler is approx. 78 wt%, including inorganic filler of 40
Follow the same procedure described in "A-1".
vol%. The particle size of inorganic fillers ranges from 0.37μm to 1.5μm.
B-2. Preparation of fractured surfaces
If necessary, bevel the margin with a diamond polishing point. Then follow
the surface treatment procedures of the fractured area based on the
surface material (e.g. metal-oxide ceramic, silica-based ceramic,
composite, metal or tooth) according to the instructions for use for
bonding, silane coupling agents or a metal adhesive primer.

B-3. Tooth surface treatment and bonding

B-3. Tooth surface treatment and bonding
Follow the same procedure described in "A-5".
B-4. Dispensing of the paste
B-4. Dispensing of the paste
B-4. Dispensing of the paste
Select the closest "lightness/ value" tab
Select the closest "lightness/ value" tab
Select the closest "lightness/ value" tab
Follow the same procedure described in "A-6".
from 6 exposed tab options of the
shade guide.
B-5. Placement and light-curing of CLEARFIL MAJESTY ES-2
B-5. Placement and light-curing of CLEARFIL MAJESTY ES-2
B-5. Placement and light-curing of CLEARFIL MAJESTY ES-2
5-1. The application of a opaque resin (e.g. CLEARFIL ST OPAQUER) to
the fractured surfaces as an initial layer is optional. When adapting it,
refer to its instructions for use.
5-2. Place the chosen shade of the paste into the fractured surfaces and
light-cure with a dental curing unit. Considering the depth of cure,
incremental curing may be required. Refer to the table in section "A-7"
for the relationship between curing time and depth of cure with a
visible light source.

B-6. Finishing

B-6. Finishing
Follow the same procedure described in "A-8".
[CAUTION]
Federal (U.S.A.) law restricts this device to sale by or on the order of a licensed
dentist.
dentist.
[WARRANTY]
[WARRANTY]
[WARRANTY] 
Kuraray Noritake Dental Inc. will replace any product that is proven to be
Kuraray Noritake Dental Inc. will replace any product that is proven to be
Kuraray Noritake Dental Inc. will replace any product that is proven to be
Select the closest "lightness/ value" tab
Select the closest "lightness/ value" tab
Select the closest "lightness/ value" tab
defective. Kuraray Noritake Dental Inc. does not accept liability for any loss or
defective. Kuraray Noritake Dental Inc. does not accept liability for any loss or
defective. Kuraray Noritake Dental Inc. does not accept liability for any loss or
from 6 exposed tab options of the
damage, direct, consequential or special, arising out of the application or use of
damage, direct, consequential or special, arising out of the application or use of
damage, direct, consequential or special, arising out of the application or use of
shade guide. For the teeth lighter than
shade guide. For the teeth lighter than
or the inability to use these products. Before using, the user shall determine the
or the inability to use these products. Before using, the user shall determine the
or the inability to use these products. Before using, the user shall determine the
"W" shade, pull-out the tab for "XW"
"W" shade, pull-out the tab for "XW"
suitability of the products for the intended use and the user assumes all risk and
suitability of the products for the intended use and the user assumes all risk and
suitability of the products for the intended use and the user assumes all risk and
shade taking. 
liability whatsoever in connection therewith.
liability whatsoever in connection therewith.
liability whatsoever in connection therewith.
[NOTE]  
[NOTE]
"CLEARFIL", "CLEARFIL MAJESTY" and "CLEARFIL ST" are trademarks of
"CLEARFIL", "CLEARFIL MAJESTY" and "CLEARFIL ST" are trademarks of
KURARAY CO., LTD.
KURARAY CO., LTD.
"VITA" is a trademark of VITA Zahnfabrik, Bad Sackingen, Germany.
"VITA" is a trademark of VITA Zahnfabrik, Bad Sackingen, Germany.
• Select the corresponding pastes of Premium shades (Enamel/Dentin).
• Select the corresponding pastes of Premium shades (Enamel/Dentin).
• Select the corresponding pastes of Premium shades (Enamel/Dentin).
• Select the corresponding pastes of Premium shades (Enamel/Dentin).
For example, if A1 tab is chosen, then select A1E and A1D shades.
For example, if A1 tab is chosen, then select A1E and A1D shades.
For example, if A1 tab is chosen, then select A1E and A1D shades.
For example, if A1 tab is chosen, then select A1E and A1D shades.
• Replace dentin space with a respective Dentin shade, and enamel space
with a respective Enamel shade.
dwarfed tooth, etc.)
Clean the tooth with pumice and water to remove surface stains, then
select the appropriate shade according to the above "Shade taking and
restorative technique".
Avoid contamination of the treatment area from saliva or blood to produce
optimal results. A rubber dam is recommended to keep the tooth clean and
dry.
Remove any infected dentin and prepare the cavity in the usual manner.
Any actual or near pulp exposure could be covered with a hard setting
calcium hydroxide material or other indicated materials. Do not use eugenol
materials for pulp protection.
Tooth surface treatment and bonding should be performed according to the
Manufactured by
instructions for use of the bonding system used. 
1621 Sakazu, Kurashiki, Okayama 710-0801, Japan
Distributed by
6-1. Syringe : Dispense the necessary amount of paste from the syringe
KURARAY AMERICA, INC.
onto the mixing pad by turning the handle slowly in a clockwise
33 Maiden Lane, 6th Floor, New York, NY 10038
manner.
Te l.(800)879-1676
Fax.(888)700-5200
FRANÇAIS
MODE D'EMPLOI
I. INTRODUCTION
CLEARFIL MAJESTY ES-2 est un matériau de restauration photopolymérisable
radiopaque permettant une conformité quasi absolue des couleurs, facile à polir
et possédant d'excellentes propriétés physiques, ce qui le rend idéal pour la
restauration aussi bien des dents antérieures que postérieures. Le produit se
présente sous forme de seringues traditionnelles ou de d'embouts pré-dosés
(PLTs).
Le système unique de prise de teintes du teintier CLEARFIL MAJESTY ES-2,
basé sur « lightness/ value », permet de sélectionner une teinte (Classic) ou
des teintes multiples (Premium) pour des restaurations très esthétiques.
II. INDICATIONS
CLEARFIL MAJESTY ES-2 est indiqué pour les applications restauratrices
suivantes:
[1] Restauration directe de toutes classes de cavités des dents antérieures et
postérieures
[2] Facettes directes
Shade and depth of cure
[3] Correction de la position et de la forme des dents (par ex. fermeture de
XW,W,A1,A2,A3,A3.5
Clear
A6
Curing
diastème, dent naine, etc.)
B1,B2,B3,B4
A4,C4
Amber
A3D
time
WD,XWD
C1,C2,C3,D2,D3
[4] Restauration intraorale de prothèses facturées
Gray
A3.5D
XWE,WE,A1E,A2E
A1D,A2D
Blue
A4D
A3E,A3.5E,A4E
III. CONTRE-INDICATIONS
Twice for
Patients connus pour leur hypersensibilité aux monomères de méthacrylate
2
)
3 or 5 sec.
10 sec.
IV. INCOMPATIBILITÉS
2
)
Ne pas utiliser de matériaux contenant de l'eugénol pour la protection de la
20 sec.
3.0 mm
2.0 mm
1.5 mm
1.0 mm
)
pulpe ou un scellement temporaire, étant donné que l'eugénol pourrait retarder
2
le processus de polymérisation.
10 sec.
)
2
V. PRECAUTIONS
20 sec.
1. Consignes de sécurité
)
2
1. Ce produit contient des substances susceptibles de provoquer des réactions
allergiques. L'utilisation de ce produit chez les patients présentant une
allergie connue aux monomères méthacryliques ou à d'autres composants
est vivement déconseillée.
2. Si le patient présente une réaction d'hypersensibilité sous forme d'érythème,
d'eczéma, de signes caractéristiques d'inflammation, d'ulcère, de
gonflement, de prurit ou d'engourdissement, cesser l'utilisation du produit et
demander un avis médical.
3. Portez des gants ou prenez les mesures de protection nécessaires pour
éviter une hypersensibilité pouvant être causée par tout contact avec les
monomères de méthacrylate ou à d'autres composants. 
4. Faire preuve de précaution pour empêcher le produit d'entrer en contact avec
la peau ou les yeux. Avant l'utilisation, couvrir les yeux du patient avec une
serviette pour les protéger des projections.
5. En cas de contact du produit avec les tissus du corps humain, prendre les
mesures suivantes :
<En cas de pénétration du produit dans les yeux>
Rincer immédiatement les yeux abondamment à l'eau et consulter un
médecin.
<En cas de contact entre le produit et la peau ou les muqueuses buccales>
Essuyez immédiatement avec un tampon ouaté ou de la gaze imprégné
d'alcool, puis rincez abondamment à l'eau.
6. Prenez les mesures nécessaires pour éviter que le patient n'avale
accidentellement le produit.
7. Seringue : Afin d'éviter toute contamination croisée, évitez d'utiliser la même
pâte pour différents patients. Avant utilisation, exprimer la pâte sur un bloc de
mélange. Ne pas essayer d'appliquer directement la pâte à partir d'une
seringue sur la dent du patient.
8. PLT : À usage unique. Ne pas réutiliser l'embout afin d'éviter toute
contamination croisée. L'éliminer après usage et stériliser le pistolet
conformément au mode d'emploi de ce dernier.
2. Précautions pour la manipulation
【CLEARFIL MAJESTY ES-2】
1. Le produit ne doit pas être utilisé dans tout autre but que ceux spécifiés dans
les [II.INDICATIONS].
2. L'utilisation de ce produit est limitée à l'usage des chirurgiens dentistes
agréés.
3. Utiliser un agent de coiffage pulpaire dans une cavité à proximité de la pulpe
ou en cas d'exposition accidentelle de la pulpe.
4. Utiliser une digue en caoutchouc pour éviter toute contamination et contrôler
l'humidité.
5. Ne pas utiliser le produit conjointement à d'autres matériaux composites. Les
matériaux mélangés peuvent modifier les propriétés physiques et
éventuellement diminuer les performances escomptées.
6. La pâte devrait être utilisée immédiatement après avoir été sortie de la
seringue ou de l'embout. Si la pâte n'est pas utilisée directement pendant un
certain temps, elle devra être recouverte d'une plaquette protégeant de la
lumière.
7. Si vous utilisez un embout pré-dosé PLT, exercez une pression lente et
continue sur le pistolet. Une force excessive n'est pas nécessaire.
8. Si vous utilisez un teintier, suivez les procédures ci-dessous pour éviter toute
contamination croisée.
• Couvrir l'intégralité du teintier à l'aide d'une protection jetable (comme un
sac en plastique) afin d'éviter toute contamination par la salive et le sang.
• Le désinfecter avant et après utilisation en le frottant correctement avec un
coton absorbant imbibé d'alcool.
【Unité dentaire de photopolymérisation】
1. Ne pas regarder directement vers la source lumineuse. Le port de lunettes de
protection est recommandé.
2. Une faible intensité lumineuse provoquera une adhérence médiocre. Vérifier
la lampe quant à sa durée de vie et l'embout de guidage de la lampe de
polymérisation dentaire quant à une éventuelle contamination. Il est
recommandé de vérifier l'intensité de la lampe de polymérisation dentaire en
utilisant à intervalles périodiques un dispositif d'évaluation de l'intensité
lumineuse.
3. L'embout émetteur de l'unité dentaire de polymérisation doit être tenu le plus
près et le plus possible à la verticale par rapport à la surface de la résine. Si
une surface importante de résine doit être photopolymérisée, il est
recommandé de la diviser en différentes sections et de les photopolymériser
chacune séparément.
4. Vérifier les conditions requises pour la polymérisation de la pâte en se
référant aux durées de photopolymérisation listées dans ce mode d'emploi
avant d'utiliser le produit. 
3. Consignes de conservation
1. Le produit doit être utilisé avant la date de péremption indiquée sur
l'emballage.
2. Le produit et le teintier doivent être conservés à 2 – 25℃ / 36 – 77°F
lorsqu'ils ne sont pas utilisés.
3. Lorsque le produit est conservé au réfrigérateur, il doit être laissé à température
ambiante avant chaque utilisation pendant au moins 15 minutes. En cas de non
observation, la seringue ou l'embout pré-dosé risquent de casser.
4. Le produit et le teintier ne doivent pas être exposés à une chaleur extrême ou
directement à la lumière du soleil.
5. Après que la pâte a été sortie, la seringue doit être fermée hermétiquement le
plus vite possible, afin d'empêcher que la lumière ambiante ne durcisse le
matériau et que des corps étrangers n'entrent dans la seringue.
6. Le produit doit être conservé dans un endroit adéquat, auquel seuls des
dentistes ont accès.
VI. SHADES SYSTEM AND COMPONENTS
1. Shades
CLEARFIL MAJESTY ES-2 est disponible en 18 teintes Classic, 14 teintes
Premium et 4 teintes Translucent :
1) Classic: XW, W, A1, A2, A3, A3.5, A4, *A6,
B1, B2, B3, B4, C1, C2, C3, C4, D2, D3
2) Premium
-Enamel: XWE, WE, A1E, A2E, A3E, A3.5E, A4E
-Dentin : XWD, WD, A1D, A2D, *A3D, *A3.5D, *A4D
3) Translucent; Clear, Amber, Blue, Gray
*A6, A3D, A3.5D et A4D sont colorés opaque.
Description des teintes
Les teintes sont classées par « lightness/ value » et selon la méthode
d'application recommandée.
Les teintes Classic sont conçues pour les restaurations à teinte unique et
les teintes Premium pour les restaurations à teintes multiples. La
combinaison des teintes Premium A comprend 3 teintes Classic (VITA).
Élevée
Lightness/ Value
Faible
Méthode
Catégorie
Teinte
d'application
de teinte
Teinte unique
Classic
XW W B1 A1 B2 D2 A2 C1 C2 A3 D3 B3 A3,5 B4 C3 A4
C4
Enamel
XWE WE
A1E
A2E
A3E
A3,5E
A4E
Teintes
Premium
multiples
Dentin
XWD WD
A1D
A2D
A3D
A3,5D
A4D
[REMARQUE]
Vous pouvez utiliser les teintes Translucent pour la caractérisation
amélaire de la restauration. A6 a la luminosité la plus faible dans les
teintes Classic.
2. Composants
Principaux contenus
• CLEARFIL MAJESTY ES-2
Accessoires
• Shade guide [Teintier (toutes les teintes décrites ci-dessus)]
• Shade guide compact [Teintier compact (teintes Classic sauf A6)]
Veuillez vous reporter à l'emballage pour des informations détaillées sur le
contenu et les quantités de chaque composant.
3. Ingrédients
Principaux ingredients:
• Verre de barium silanisé
• Matériau de remplissage organique prépolymérisé
• Bisphénol A diglycidylméthacrylate
• Diméthacrylate aromatique hydrophobe
• dl-Camphoroquinone
[REMARQUE] 
La quantité totale de charges avoisine 78 % en poids, charge inorganique
de 40 % en volume comprise.
La taille des charges inorganiques est comprise entre 0,37 et 1,5 μm.
VII. PROCÉDURES CLINIQUES
Choix de la teinte et technique de restauration
Présentation des teintes dans le teintier  : Les teintes Classic, à l'exception de
A6, sont rangées dans le même ordre que les onglets de sélection expliqués
ci-dessous aux sections « Technique pour teinte unique » et « Technique
pour teintes multiples ».
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
Les teintes Translucent, Premium Enamel, Premium Dentin et A6 sont
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
rangées au niveau des onglets désignés par T, E-1, E-2, D-1 et D-2.
1. Technique pour teinte unique (système Classic)
1. Technique pour teinte unique (système Classic)
1. Technique pour teinte unique (système Classic)
1. Technique pour teinte unique (système Classic)
1. Technique pour teinte unique (système Classic)
Étape 1 :
Choisissez la « lightness/ value » la
Choisissez la « lightness/ value » la
plus proche parmi les 6 onglets
proposés dans le teintier.
Étape 2 :
Retirez l'onglet choisi de son support et sélectionnez la teinte
Retirez l'onglet choisi de son support et sélectionnez la teinte
Retirez l'onglet choisi de son support et sélectionnez la teinte
Retirez l'onglet choisi de son support et sélectionnez la teinte
correspondante.
correspondante.
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
Par exemple, si vous choisissez l'onglet A2, vous pouvez sélectionner les
teintes D2, A2 ou C1, comme indiqué ci-dessous.
teintes D2, A2 ou C1, comme indiqué ci-dessous.
     
            
            
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
2. Technique pour teintes multiples (système Premium)
Choisissez la « lightness/ value » la
Choisissez la « lightness/ value » la
Choisissez la « lightness/ value » la
Choisissez la « lightness/ value » la
plus proche parmi les 6 onglets
proposés dans le teintier. Pour les
dents plus claires que la teinte « W »,
dents plus claires que la teinte « W »,
choisissez l'onglet « XW ». 
• À partir du « tableau des teintes multiples », choisissez les pâtes
• À partir du « tableau des teintes multiples », choisissez les pâtes
• À partir du « tableau des teintes multiples », choisissez les pâtes
• À partir du « tableau des teintes multiples », choisissez les pâtes
correspondant aux teintes Premium (Enamel/Dentin). Par exemple, si
correspondant aux teintes Premium (Enamel/Dentin). Par exemple, si
correspondant aux teintes Premium (Enamel/Dentin). Par exemple, si
correspondant aux teintes Premium (Enamel/Dentin). Par exemple, si
vous choisissez l'onglet A1, sélectionnez ensuite les teintes A1E et A1D.
vous choisissez l'onglet A1, sélectionnez ensuite les teintes A1E et A1D.
vous choisissez l'onglet A1, sélectionnez ensuite les teintes A1E et A1D.
vous choisissez l'onglet A1, sélectionnez ensuite les teintes A1E et A1D.
• Comblez le volume correspondant à la dentine avec une teinte Dentin
correspondante et le volume d'émail par une teinte Enamel
correspondante.
A. Procédure standard I (indications [1] à [3])
[1] Restauration directe de toutes classes de cavités des dents antérieures et
postérieures
[2] Facettes directes
[3] Correction de la position et de la forme des dents (par ex. fermeture de
diastème, dent naine, etc.)
A-1. Choix de la teinte
Nettoyez la dent avec un mélange de pierre ponce et d'eau afin de retirer
les colorations de surface, puis choisissez la teinte correspondante comme
indiqué à la section « Choix de la teinte et technique de restauration ».
A-2. Isolation et contrôle de l'humidité
Pour obtenir les meilleurs résultats possibles, éviter que la surface à traiter
soit contaminée par de la salive ou de l'exsudat. Il est conseillé de poser
une digue en caoutchouc pour maintenir la dent propre et sèche.
A-3. Préparations de la cavité
Retirer toute la dentine infectée et préparer la cavité de la manière
habituelle.
A-4. Protection de la pulpe
Toute exposition directe ou indirecte de la pulpe pourrait être couverte au
moyen d'un matériau en hydroxyde de calcium à prise dure ou d'un autre
matériau indiqué. Ne pas utiliser de matériaux contenant de l'eugénol pour
la protection de la pulpe.
C3020-KAI-omote 420×480mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clearfil Majesty ES-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kuraray America Clearfil Majesty ES-2

  • Page 1 Shades are arranged according to the “lightness/ value” and recommended CLEARFIL ST OPAQUER) to the cavity as an initial layer is optional. Le système unique de prise de teintes du teintier CLEARFIL MAJESTY ES-2, Les teintes sont classées par « lightness/ value » et selon la méthode CLEARFIL MAJESTY ES-2 is a light-cure, radiopaque restorative material layering method.
  • Page 2 Fabriqué par 1. Colores Fabricado por CLEARFIL MAJESTY ES-2 está disponible en los siguientes 18 colores de A-4. Protección de la pulpa Cualquier punto de la pulpa, o cercano a ella, que quede expuesto podría 1621 Sakazu, Kurashiki, Okayama 710-0801, Japan...

Table of Contents