Description The Edwards VS16K adjustable vacuum switch contains a pressure sensitive diaphragm which operates a non latching snap action microswitch. The switch can be used to operate an electrical circuit when the system pressure rises or falls through an operator-determined pressure set point between 30 and 1000 mbar.
Remove all packing materials and protective covers and check the VS16K for damage. If the VS16K is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the VS16K together with your order number and your supplier's invoice number. Retain all packing materials for inspection. Do not use the VS16K.
Page 17
Complete the Declaration (HS2) and send it to Edwards before you dispatch the equipment. It is important to note that this declaration is for Edwards internal use only, and has no relationship to local, national or international transportation safety or environmental requirements.
Page 18
Read the Return of Edwards Equipment – Procedure (HS1) before you complete this Declaration • Contact Edwards to obtain a Return Authorisation Number and to obtain advice if you have any questions • Send this form to Edwards before you return your equipment as per the procedure in HS1...