D059-15-880
Issue D Original
Instruction Manual
Adjustable Vacuum Interlock Switch VS16K
Description
Item Number
Adjustable Vacuum Interlock Switch VS16K
D059-15-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VS16K and is the answer not in the manual?

Questions and answers

Summary of Contents for Edwards VS16K

  • Page 1 D059-15-880 Issue D Original Instruction Manual Adjustable Vacuum Interlock Switch VS16K Description Item Number Adjustable Vacuum Interlock Switch VS16K D059-15-000...
  • Page 3: Table Of Contents

    Storage ........................8 Disposal ........................8 Index ....................9 For return of equipment, complete the HS Forms at the end of this manual. © Edwards Limited 2009. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 4 Vacuum switch plug connections ..................5 Dimensions of VS16K vacuum switch .................. 7 Tables Table Page Maximum switch ratings ....................2 Page ii © Edwards Limited 2009. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 5: Introduction

    Description The Edwards VS16K adjustable vacuum switch contains a pressure sensitive diaphragm which operates a non latching snap action microswitch. The switch can be used to operate an electrical circuit when the system pressure rises or falls through an operator-determined pressure set point between 30 and 1000 mbar.
  • Page 6: Technical Data

    Maximum switch ratings for different loads and voltages: Table 1 - Maximum switch ratings Volts Resistive Load Motor Load a.c. 50/60Hz Amps (HP) 0.125 0.25 d.c. volts 0.25 Page 2 © Edwards Limited 2009. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 7: Product Item Number

    D059-15-880 Issue D Product item number Description Item Number Adjustable vacuum switch D059-15-000 © Edwards Limited 2009. All rights reserved. Page 3 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 8: Installation

    Remove all packing materials and protective covers and check the VS16K for damage. If the VS16K is damaged, notify your supplier and the carrier in writing within three days; state the Item Number of the VS16K together with your order number and your supplier's invoice number. Retain all packing materials for inspection. Do not use the VS16K.
  • Page 9 Tighten the cable gland and connect the socket to the switch using the sealing gasket and locking screw provided. © Edwards Limited 2009. All rights reserved. Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 10: Operation

    7. Repeat steps 5 and 6 as necessary. 8. Replace the plastic plug and reconnect the mPm socket. 9. Reconnect the electrical supply. Page 6 © Edwards Limited 2009. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 11: Maintenance

    2. The outer surfaces of the switch may be cleaned by wiping with a dry cloth. Avoid the use of solvents that may attack the moulded cover. 3. This product contains no user serviceable parts. Figure 2 - Dimensions of VS16K vacuum switch © Edwards Limited 2009. All rights reserved. Page 7 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 12: Storage And Disposal

    Dispose of the switch in accordance with any local or national safety requirements. Particular care must be taken if the switch has been used in a hazardous environment. Page 8 © Edwards Limited 2009. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 13: Index

    Performance ..........2 Product item number ........3 Scope and definitions ........1 STORAGE AND DISPOSAL ........8 TECHNICAL DATA ..........2 Unpacking and inspection ........4 © Edwards Limited 2009. All rights reserved. Page 9 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 14 D059-15-880 Issue D Page 10 © Edwards Limited 2009. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 15 This page intentionally blank.
  • Page 16 This page intentionally blank.
  • Page 17 Complete the Declaration (HS2) and send it to Edwards before you dispatch the equipment. It is important to note that this declaration is for Edwards internal use only, and has no relationship to local, national or international transportation safety or environmental requirements.
  • Page 18 Read the Return of Edwards Equipment – Procedure (HS1) before you complete this Declaration • Contact Edwards to obtain a Return Authorisation Number and to obtain advice if you have any questions • Send this form to Edwards before you return your equipment as per the procedure in HS1...