II°CH RADIO SERVICE/ZONE LIGHT AUX1:2 Service Light AUX1:0 AUX1:1 AUX1:3 Zone Light 24Vac 1A max SCA 24Vac 3W max Service/Zone Light 230Vac Relè 24Vac...
Page 4
Via Capitello, 45 - 36066 Sandrigo (VI) – Italy It is hereby stated that the item: Control unit for 1 motor, 24VDC, for sectional doors: CP.J4 ESA it is compliant with provisions of the following other EC Directives: • DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004, on...
Operating temp. -20°C / +70°C Radio receiver built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code) Memory capacity 64 rolling-code transmitters CONTROL PANEL CP.J4 ESA WIRE DIAGRAM Wire connections shown in Fig. 1 are described hereunder: Terminals Function Description...
Page 6
RUN SELF-LEARNING AND ANTI-CRUSHING DEVICE SETTING When operator assembly and wiring is completed, parameters and logic are programmed, self learning allows the operator to learn the stroke and self adjusts amperometric sensor thresholds. First of all place the opening and closing mechanical stops: - manually release the door and completely close it.
Page 7
If it is memorized with the SAIR radio function, the partial opening width is adjusted through the second channel of the transmitter. The TCA Sair automatic closure has no effect on the partial opening. 3-250-(5) Partial opening is allowed only if the door is completely closed The value is expressed in centimetres.
Page 8
During the TCA time, the blinker is enabled or disabled. LTCA On: Enables blinker. (OFF) Off: Disables blinker. The code programmable transmitters is enabled or disabled. On: Radio receiver enabled only for rolling-code transmitters. CVAR (OFF) Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and Dip Switch).
Page 9
By selecting this function, the receiver is waiting for (Push) a transmitter code to be erased from memory. If the code is valid, it will be stored in memory and OK will be displayed. If the code is not valid, the Err message will be displayed. The memory of the receiver is entirely erased.
EMERGENCY BATTERY An optional accessory to power the control unit is available in the event the mains power supply is cut off. The kit is composed of a battery charger and two 12V rechargeable batteries, fixing brackets, screws and cables. For further information, please refer to instructions supplied with the accessory.