Summary of Contents for Enerdrive ePOWER EN43020

  • Page 1 SOLAR CHARGE CONTROLLERS Owner’s Manual SMART AUTOMATIC 12/24 VOLT PWM SOLAR CONTROLLER 4 STAGE CHARGING EN43020 - 20A EN43030 - 30A...
  • Page 2: Notice Of Copyright

    Shall in no event be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of purchase or use of these Enerdrive products. The sole and exclusive liability to Enerdrive, regardless of the form of action, shall not exceed the purchase price of the Enerdrive products described here.
  • Page 3 Standard features of the ePOWER include automatic overload, low battery, overheating and built-in short circuit protection. The ePOWER Solar Charge Controller is well equipped to give you lasting trouble-free operation. ePOWER Solar Charge Controller Features Page 3 www.enerdrive.com.au...
  • Page 4: Important Safety Information

    This section contains important safety information for the Enerdrive ePOWER Solar Charge Controller. Each time, before using the Enerdrive ePOWER Solar Charge Controller, READ ALL instructions and cautionary markings on or provided with the controller, and all appropriate sections of this guide.
  • Page 5 FIRE AND/OR CHEMICAL BURN HAZARD Page 5 www.enerdrive.com.au...
  • Page 6: Mounting The Device

    The Solar Controller is best mounted on a vertical surface for maximum cooling efficiency. To mount the unit, use self-tapping screws and mount the unit via the four screw holes supplied and affix to a flat surface. 145mm 70mm EN43020 175mm 80mm EN43030 Page 6 www.enerdrive.com.au...
  • Page 7: Wiring Connections

    The ePOWER Solar Charge Controller is a common Positive Controller. NOTE: If using an inverter, or have a load larger than the load output of the solar controller, connect the inverter and/or large load/s directly to the battery. Page 7 www.enerdrive.com.au...
  • Page 8 Remote Temperature Sensor (RTS) port built-in. Optional sensor probe available PN# EN43-TEMP (Temp compensation will be fixed at 25°c without the RTS installed). • Multiple protections against reverse polarity, short circuit, over temperature, over voltage, etc. • IP Rating: IP30 Page 8 www.enerdrive.com.au...
  • Page 9: Status Display

    Operation: Battery Function Button Function Browse through screens MENU Button Setting parameter Load ON/OFF Clear error SET Button Enter into SET Mode Save data Status Display Page 9 www.enerdrive.com.au...
  • Page 10 5 seconds and the value will blink. Press the SET button again to clear the value. Setting temperature on the controller: Under the battery temperature screen, press the SET button and hold on for 5 seconds to switch between Fahrenheit or Celsius. Page 10 www.enerdrive.com.au...
  • Page 11: Fault Indication

    Load failure When the load current reaches 1.02–1.05 times 1.05–1.25 times, 1.25–1.35 times and 1.35–1.5 times more than the nominal value, the controller will automatically turn off the loads in 50s, 30s,10s and 2s respectively. Page 11 www.enerdrive.com.au...
  • Page 12 Battery Type Menu. Choose the battery type by pressing the MENU button, and then press the SET button to select the chosen battery type. NOTE: Please refer to the battery voltage parameters table for the different battery type. Page 12 www.enerdrive.com.au...
  • Page 13 Clear the fault: RESTART 1.05-1.25 times, 30s, the controller or wait for 1.25-1.35 times, 10s, one night-cycle 1.35-1.5 times 2s Damaged RTS (Temp Sensor) If the RTS is either short circuited or Controller will operate at damaged a standard 25˚C Page 13 www.enerdrive.com.au...
  • Page 14: Troubleshooting

    When the battery voltage is restored to Battery over discharged or above LVR (low voltage reconnect voltage) point, the load will recover Icon blinking Battery over heating Icon blinking Reduce the output loads and/or check Over load or short circuit load terminal connections Page 14 www.enerdrive.com.au...
  • Page 15: Specifications

    Grounding Common Positive 5VDC/2.4A (Total) USB output Overall dimension 160 x 95 x 50mm 181 x 101 x 60mm Mounting dimension 148 x 70mm 172 x 80mm Mounting hole size Ø4.5mm Ø5.0mm Terminals Net weight 0.35kg 0.55kg Page 15 www.enerdrive.com.au...
  • Page 16: Warranty Statement

    30 days of original purchase. Any defective unit that is returned to Enerdrive within 30 days of the date of purchase will be replaced free of charge.
  • Page 17 If such a unit is returned more than 30 days but less than two years from the purchase date, Enerdrive will repair the unit or, at its option, replace it, free of charge. If the unit is repaired, new or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be replaced with a new or reconditioned unit of the same or c omparable design.
  • Page 18 ENERDRIVE PTY LTD P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178 Ph: 1300 851 535 / Fax: 07 3390 6911 Email: sales@enerdrive.com.au Web: www.enerdrive.com.au...