Velopex md3000 medical Technical Manual

Automatic x-ray film processor

Advertisement

Quick Links

MODEL:
MEDICAL
MED
INDUSTRIAL
NDT
www.velopex.com
Hi-Tech
Diagnostics
Service
MAKERS OF DENTAL, VETERINARY AND MEDICAL EQUIPMENT
Automatic X-Ray Film Processor
TECHNICAL MANUAL
FOR TRAINED TECHNICAL PERSONNEL
WARNING:
Do not plug into the electrical mains power supply before
reading this manual.
I/LIT0311P MD3000 Technical Manual Iss.2
Issued: 08/09/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the md3000 medical and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Velopex md3000 medical

  • Page 1 MEDICAL INDUSTRIAL TECHNICAL MANUAL FOR TRAINED TECHNICAL PERSONNEL WARNING: Do not plug into the electrical mains power supply before reading this manual. Hi-Tech Diagnostics Service www.velopex.com MAKERS OF DENTAL, VETERINARY AND MEDICAL EQUIPMENT I/LIT0311P MD3000 Technical Manual Iss.2 Issued: 08/09/11...
  • Page 2: Table Of Contents

    Contents OVERVIEW Machine Exterior Machine Interior - Control Side Machine Interior - Tank Side Control Panel Control Panel Extended Menu Machine Specification Pre-Installation Instructions Plumbing MED Plumbing NDT DIAGRAMS Opening machine Main Assembly Motor Board Assembly Motor Board Sub Assembly Control Panel Assembly Dryer Module Assembly Pump Assembly...
  • Page 3: Machine Exterior

    VELOPEX MD3000 VELOPEX MD3000 Instructions for use Instructions for use Machine Exterior IDENTIFYING YOUR MACHINE MD3000 MEDICAL MD3000 INDUSTRIAL MACHINE ACCESSORIES SUPPLIED MACHINE ACCESSORIES SUPPLIED Automatic X-Ray Film Processor INSTRUCTIONS FOR USE Operation and Maintenance manual WARNING: Do not plug into the electrical mains power supply before...
  • Page 4: Machine Interior - Control Side

    Machine Interior - Control Side Display Board Drive Motor Power Supply IEC Board Dryer Assembly Tube in/outlet Cam Switch Assembly Manifold Assembly Pump Assembly Heater Assembly...
  • Page 5: Machine Interior - Tank Side

    Machine Interior - Tank Side Drive Dogs (x4) Heater Grill Assembly with Sensor Water sensor (not shown) Water suction pipe Water sensor (not shown) Water suction pipe Water sensor (not shown) Water suction pipe Film Entry Beak with Initiation Sensor Developer Tank Developer Spreader Bar Fixer Tank...
  • Page 6: Control Panel

    Control Panel CURSER MACHINE STATUS Ready, Warming, Cleaning, Draining MADE IN ENGLAND BY MEDIVANCE INSTRUMENTS LTD PROCESSING DURATION READY RUN TIME 1M30S > DEVELOPER CHEMICAL DEV TEMP 26°C TEMPERATURE FIX TEMP 26°C 25°C - 30°C FIXER CHEMICAL TEMPERATURE 25°C - 30°C Water temperature will automatically set to the same temperature as the Fixer.
  • Page 7: Control Panel Extended Menu

    Control Panel Extended Menu EXTENDED MENU Use the Up & Down buttons to MADE IN ENGLAND BY MEDIVANCE INSTRUMENTS LTD locate settings and functions. READY REFRESH RATE 25 ML CHEMISTRY REFRESH RATE > FILL /REFRESH 25ml - 300ml per cycle. DRAIN TANK CHEMICAL VOLUME 1 Litre - 4 Litre...
  • Page 8: Machine Specification

    Machine Specification TABLE OF SYMBOLS 580 mm Depth (D) 616 mm Including Loader 951 mm Height (H) 327 mm Including Film Catcher 655 mm Weight Empty 40 Kg Full Tanks 55 Kg Including Loader 70 Kg Tank Capacity 0.5-4. Litre Operating Temperature Developer 25°...
  • Page 9: Pre-Installation Instructions

    Pre-Installation Instructions MINIMUM WORK TOP MACHINE TROLLEY • Siting of the VELOPEX When using the machine in daylight or a darkroom, avoid sources of intense light. 620mm Do not mount the unit under a window, fluorescent light or flood lamp.
  • Page 10: Plumbing Med

    Plumbing - Medical (MED) CLEANING DEVELOPER FIXER FRESH DRAIN SOLUTION CHEMICAL CHEMICAL WATER...
  • Page 11: Plumbing Ndt

    Plumbing - Industrial (NDT) MAINS SUPPLY cut excess WASTE DEVELOPER FIXER CLEANING DRAIN CHEMICAL CHEMICAL CHEMICAL SOLUTION FOR DISPOSAL...
  • Page 12: Opening Machine

    Opening Machine ELECTRONIC CONTROL SIDE TANK SIDE...
  • Page 13: Main Assembly

    Main Assembly...
  • Page 14: Motor Board Assembly

    Motor Board Assembly...
  • Page 15: Motor Board Sub Assembly

    Motor Board Sub Assembly...
  • Page 16: Control Panel Assembly

    Control Panel Assembly...
  • Page 17: Dryer Module Assembly

    Dryer Module Assembly...
  • Page 18: Pump Assembly

    Pump Assembly...
  • Page 19: Cam Block Assembly

    Cam Block Assembly...
  • Page 20: Film Catcher

    Film Catcher...
  • Page 21: Tank Assembly

    Tank Assembly...
  • Page 22: Daylight Loader

    Daylight Loader...
  • Page 23: Machine Stand

    Machine Stand Assembly...
  • Page 24: Electrical Layout

    Electrical Layout...
  • Page 25: Plumbing - Internal

    Plumbing - Internal...
  • Page 26: Trouble Shooting

    Trouble Shooting..coming soon...
  • Page 27 London, NW10 7AP, UK Tel: +44 (0)20 8965 2913 Fax: +44 (0)20 8963 1270 ETL LISTED/ENREGISTRÉ ETL CONFORMS TO/CONFORME À Velopex International s.a.r.l UL 61010-1 14 route de Montreuil le Gast THIS PRODUCT HAS BEEN TESTED B.P.45, 35520 Melesse, France TO THE REQUIREMENTS OF Tel: +33 (0) 2.99.13.22.59...

This manual is also suitable for:

Md3000 industrial

Table of Contents