Focal Technologies Corporation Moog 920 Manual

Ethernet data multiplexer
Table of Contents

Advertisement

Quick Links

Model 920 Ethernet Data Multiplexer Manual
MOOG PROPRIETARY AND CONFIDENTIAL INFORMATION
THIS TECHNICAL DATA/DRAWING/DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO, AND IS THE EXPRESS PROPERTY OF MOOG
INC., OR MOOG INC. SUBSIDIARIES EXCEPT AS EXPRESSLY GRANTED BY CONTRACT OR BY OPERATION OF LAW AND IS RESTRICTED TO USE
BY ONLY MOOG EMPLOYEES AND OTHER PERSONS AUTHORIZED IN WRITING BY MOOG OR AS EXPRESSLY GRANTED BY CONTRACT OR BY
OPERATION OF LAW. NO PORTION OF THIS DATA/DRAWING/DOCUMENT SHALL BE REPRODUCED OR DISCLOSED OR COPIED OR FURNISHED
IN WHOLE OR IN PART TO OTHERS OR USED BY OTHERS FOR ANY PURPOSE WHATSOEVER EXCEPT AS SPECIFICALLY AUTHORIZED IN
WRITING BY MOOG INC. OR MOOG INC. SUBSIDIARY.
Focal Technologies Corporation
A Moog Inc. Company
77 Frazee Avenue
Dartmouth, Nova Scotia, Canada B3B 1Z4
Tel: (902)468-2263 | www.moog.com/focal
Document No.:
Date of Issue:
920-0603-00
Revision:
Rev K
Author(s):
E. Mullaley
2017-03-07

Advertisement

Table of Contents
loading

Summary of Contents for Focal Technologies Corporation Moog 920

  • Page 1 Focal Technologies Corporation A Moog Inc. Company 77 Frazee Avenue Dartmouth, Nova Scotia, Canada B3B 1Z4 Tel: (902)468-2263 | www.moog.com/focal Model 920 Ethernet Data Multiplexer Manual Document No.: 920-0603-00 Revision: Rev K Author(s): E. Mullaley Date of Issue: 2017-03-07 MOOG PROPRIETARY AND CONFIDENTIAL INFORMATION THIS TECHNICAL DATA/DRAWING/DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO, AND IS THE EXPRESS PROPERTY OF MOOG INC., OR MOOG INC.
  • Page 2 Removed PHY Control from Diagnostics. This feature has 2017 Mar 7 been disabled to increase product reliability. Reference Documents Document Document Title and Description Number 920-2003-00 Model 920 EDM Configuration Drawing Focal Technologies Corporation Page i A Moog Inc. Company 920-0603-00 Rev K...
  • Page 3: Table Of Contents

    Installation ............................. 6-1 Power ............................6-1 Bench Test............................ 6-2 Electrical and Environmental Specifications ................. 6-3 Maintenance ..........................6-3 Model 920 EDM Product Handling ....................6-4 Appendices ............................7-1 Focal Technologies Corporation Page ii A Moog Inc. Company 920-0603-00 Rev K...
  • Page 4 Figure 13: Sample .NET GUI for Modbus TCP Access to Model 920 ............. 3-3 Figure 14: Telnet Interface ..........................4-1 Figure 15: Model 920 EDM Rear with DIN Rail Mount Adaptors ..............6-1 Focal Technologies Corporation Page iii A Moog Inc. Company...
  • Page 5 Small Form-factor Pluggable (Optical Transceiver) Surface Mount Technology ST/PC Straight Tip optical connector / Physical Contact Time Division Multiplexer / Multiplexing Transistor-Transistor Logic VOAT Variable Optical Attenuator Wavelength Division Multiplexer / Multiplexing Focal Technologies Corporation Page iv A Moog Inc. Company 920-0603-00 Rev K...
  • Page 6: Introduction

    Appendices in Section 7.0 include a cross-reference for card configuration drawing and any system specific information, if provided, such as relevant installation drawings and configuration drawings. Figure 1: Model 920 EDM Focal Technologies Corporation Page 1-1 A Moog Inc. Company...
  • Page 7: System Overview

    BASE-T while the optical link is configured for low data rates could result in data loss. (i.e. a 1000 Mbps copper link cannot be losslessly connected over a 625 Mbps optical link) Focal Technologies Corporation Page 2-1 A Moog Inc. Company...
  • Page 8: Diagnostic Ethernet Port - 10/100 Base-T(X)

    Ether CAT. Each port operates at 100 Mbps with auto-crossover capabilities provided. CAT5 or better cabling is recommended for all installations with a maximum cable length of 100m. Focal Technologies Corporation Page 2-2 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 9: Ethercat Link Latency

    EtherCAT port speed Maximum Latency NOT included fiber latency of 5 ns/m 28 s 10 BASE-T 3.7 s 100 BASE-TX Focal Technologies Corporation Page 2-3 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 10: Ethernet Channel 3, 10/100 Base-T(X) (And Optional 1000 Base-T)

    Table 4: 10/100/1000 BASE-T(X) RJ45 LED Indication Position Function Left/Top Yellow Left/Top Green Link Left/Top Green Blinking Activity Left/Top No Link Right/Bottom Green 1000 BASE-T Right/Bottom Yellow 100 BASE-TX Right/Bottom 10 BASE-T Focal Technologies Corporation Page 2-4 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 11: Ethernet Link Synchronization

    40 s of each other. Ethernet port 3 will connect or disconnect within 1 s of the corresponding port on the far side of the fiber link. Focal Technologies Corporation Page 2-5 A Moog Inc. Company...
  • Page 12: 8-Pin Header

    See section 6.1 for mating connector and cable installation guidelines. Mating Receptacle: Molex P/N 502351-0800 (Max 30 mating cycles) Crimps: Molex P/N 50212-8100 Crimp Tool: Molex P/N 63819-0500 Focal Technologies Corporation Page 2-6 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 13: Input Power

    CAN L (low) is connected to pin-6 and CAN H (high) is connected to pin-5. Table 7: CAN Bus Input Typical CAN H – CAN L Common Mode +12V Focal Technologies Corporation Page 2-7 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 14: Can Bus Output Power

    Pin-2 is an optional connection to the isolated chassis ground. This can be used to terminate cable shielding to the enclosure. 2.2.5 NC Pin-1 is a No Connect Pin. Focal Technologies Corporation Page 2-8 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 15: Leds

    Red: Optical link fault; Check Register [40006] 1 (Right) Power: Green: System is powered on Red: N/A Off: System is powered down Dim light: Problem with input power or DC-DC converter. Check input voltage/current Focal Technologies Corporation Page 2-9 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 16: Optics

    ** The 920-8000-00 and 920-8001-00 modules have an internal 62.5/125 um LC-ST fiber jumper. *** Optical transmit power and receiver sensitivity are based on transceiver limits of -15 dBm minimum transmit power at the SFP and -26 dBm receiver sensitivity. Focal Technologies Corporation Page 2-10 A Moog Inc. Company...
  • Page 17: Table 11: Optical Interface Parameters For 920-8000-01 And 920-8001-01 2.5Gbaud Mmf 1310/1550

     625 MBaud / 2.5 GBaud Optical Data Rate (1000 BASE-T operation on Ethernet Channel 3)  Alternative wavelengths, including CWDM wavelengths  Increased / decreased optical budgets Focal Technologies Corporation Page 2-11 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 18: Optical Safety

    Focal Technologies Corporation Page 2-12 A Moog Inc. Company...
  • Page 19: Diagnostics Functionality

    Modbus TCP protocol is used to provide diagnostics and user control messages via a TCP/IP connection to the Model 920. The Modbus TCP protocol stack is illustrated in Figure 12. SFP registers, card status, and control registers are accessible via Modbus TCP/IP over the Diagnostic Ethernet port. Focal Technologies Corporation Page 3-1 A Moog Inc. Company...
  • Page 20: Diagnostics And Modem Status

    SFP temperature Diagnostics and status information are retrievable using Modbus TCP. The Modbus TCP register map is provided in Section 5.0. Limited configuration information is available over Telnet, per section 4.0. Focal Technologies Corporation Page 3-2 A Moog Inc. Company...
  • Page 21: Control And Configuration Capabilities

    SFP Warning and Alarm Thresholds Values, stored in non-volatile memory within the SFPs  Ethernet PHY port Control Registers  Configuration of Network Settings (See section 3.1.1 above) Focal Technologies Corporation Page 3-3 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 22: Telnet Interface

    Typically the Telnet interface is used for convenient configuration of the TCP/IP settings of the card. Figure 14: Telnet Interface Focal Technologies Corporation Page 4-1 A Moog Inc. Company...
  • Page 23: Modbus Tcp Diagnostics

    1= 100Mbit, 0 = 10 Mbit Local Diag Ethernet Link Speed (only valid if 'Ethernet Link = 1') Local GBE_2 Ethernet Link (Local GBE_1 Ethernet Link Speed, Local GBE_2 Speed Ethernet Link Speed) Focal Technologies Corporation Page 5-1 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 24 SFP LOCAL Rx Pwr High Set when Received Power exceeds high warning level. Warning SFP LOCAL Rx Pwr Low Warning Set when Received Power is below low warning level. Reserved Focal Technologies Corporation Page 5-2 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 25 SFP REMOTE Tx Pwr High Set when TX output power exceeds high warning level. Warning SFP REMOTE Tx Pwr Low Set when TX output power is below low warning level. Warning Focal Technologies Corporation Page 5-3 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 26 Analog Alarm & Warning Thresholds (Internally Calibrated - see SFF-8472 rev 10.2 page 24 for scaling) Register Description Comments Number 40029 [15:0] SFP LOCAL Temperature High Alarm Threshold Focal Technologies Corporation Page 5-4 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 27 Threshold 40061 [15:0] SFP REMOTE Tx Power High Alarm Threshold 40062 [15:0] SFP REMOTE Tx Power Low Alarm Threshold 40063 [15:0] SFP REMOTE Tx Power High Warning Threshold Focal Technologies Corporation Page 5-5 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 28 2 ASCII characters per register 40095 [15:0] SFP LOCAL Vendor Rev Number [0] 2 ASCII characters per register 40096 [15:0] SFP LOCAL Vendor Rev Number [1] 2 ASCII characters per register Focal Technologies Corporation Page 5-6 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 29 2 ASCII characters per register 40132 [15:0] SFP REMOTE Vendor Name [5] 2 ASCII characters per register 40133 [15:0] SFP REMOTE Vendor Name [6] 2 ASCII characters per register Focal Technologies Corporation Page 5-7 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 30 2 ASCII characters per register 40172 [15:0] SFP REMOTE Focal SN [6] 2 ASCII characters per register 40173 [15:0] SFP REMOTE Focal SN [7] 2 ASCII characters per register Focal Technologies Corporation Page 5-8 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 31 Ethernet PHY Control Register Description Comments Number 40175 Reserved Ethernet PHY Control Register Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Focal Technologies Corporation Page 5-9 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 32 Board Date Code [3] 40210 [15:0] Board Date Code [4] 40211 [15:0] Board Date Code [5] 40212 [15:0] Board Date Code [6] 40213 [15:0] Board Date Code [7] Focal Technologies Corporation Page 5-10 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 33 Board Assembly Number [4] 40251 [15:0] Board Assembly Number [5] 40252 [15:0] Board Assembly Number [6] 40253 [15:0] Board Assembly Number [7] 40254 [15:0] Board PCB Number [0] Focal Technologies Corporation Page 5-11 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 34 [2]: gig_phy_led2 [1]: gig_phy_led1 [0]: gig_phy_reset_n RJ45 LEDs LED status of RJ45s [7]: gig_rj45_green_left_n [6]: gig_rj45_yellow_left_n [5]: gig_rj45_green_right_n [4]: gig_rj45_yellow_right_n [3]: eth_100_ch2_green_led_n [2]: eth_100_ch2_yellow_led_n [1]: eth_100_ch1_green_led_n [0]: eth_100_ch1_yellow_led_n Focal Technologies Corporation Page 5-12 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 35 PHY register and writes it to the PHY. A write to register zero will cause the data located at register 64 within the diagnostic PHY data I2C device address to be written to the PHY. Reserved 255-246 Focal Technologies Corporation Page 5-13 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 36: Installation And Operation

    Power Power is provided through the 8-pin connector on the front panel. Please see Section 2.2.1 for more details. Focal Technologies Corporation Page 6-1 A Moog Inc. Company...
  • Page 37: Bench Test

    A spool of fiber used with the VOAT can also be used to simulate losses due to dispersion over long cable lengths. 5. Repeat steps 1-4 with connections reversed to verify the far side to near side optical budget (uplink). Focal Technologies Corporation Page 6-2 A Moog Inc. Company...
  • Page 38: Electrical And Environmental Specifications

    The 8-pin power and CANbus connector is rated for 30 connection cycles. Avoid excessive and/or unnecessary mating cycles. Focal Technologies Corporation Page 6-3 A Moog Inc. Company...
  • Page 39: Model 920 Edm Product Handling

     Any visible damage or evidence of loose parts inside the enclosure requires removal of the modem from operation and investigation by qualified service personnel.t Focal Technologies Corporation Page 6-4 A Moog Inc. Company 920-0603-00 Rev K...
  • Page 40: Appendices

    Installation Drawing (2.5 Gb/s, 1310nm, MMF) 920-8000-01 Installation Drawing (2.5 Gb/s, 1550nm, MMF) 920-8001-01 Installation Drawing (2.5 Gb/s, 1310nm, SMF) 920-8000-02 Installation Drawing (2.5 Gb/s, 1550nm, SMF) 920-8001-02 Focal Technologies Corporation Page 7-1 A Moog Inc. Company 920-0603-00 Rev K...

Table of Contents