Advertisement

Quick Links

DIVERSITECH
Operation & Maintenance Manual
FRED CARBO
READ AND SAVE THESE INSTRUCTIONS
Visit our Website for more information on this product
www.diversitech.ca
2500 Alphonse Gariepy, Montreal, Quebec H8T 3M2
Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca
OMM-FRC-100[E N]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FRED CARBO and is the answer not in the manual?

Questions and answers

Summary of Contents for DIVERSITECH FRED CARBO

  • Page 1 DIVERSITECH Operation & Maintenance Manual FRED CARBO READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy, Montreal, Quebec H8T 3M2 Tel: 1.800.361.3733 | Fax: 1.514.631.9480 | info@diversitech.ca OMM-FRC-100[E N]...
  • Page 2: Table Of Contents

    Table of Contents SECTION 1 – SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION ...............3 1.1 Symbols ..............................3 1.2 User Responsibility ............................3 1.3 Fume Extraction Hazards ........................3 1.4 Dust Collection Hazards .........................4 1.5 Safety Stickers ............................4 1.6 Sound Levels ............................4 SECTION 2 – SPECIFICATIONS ..............................5 2.1 Diagram &...
  • Page 3: Section 1 - Safety Precautions Of Fume & Dust Extraction/Collection

    SECTION 1 - SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION This manual contains specific cautionary statements related to worker safety. To READ protect yourself and others, read this manual thoroughly and follow as directed BEFORE before use. Not all hazards of fume & dust control are listed in this manual, and no hazards related to welding, cutting, grinding, painting, deburring or other applications are listed.
  • Page 4: Dust Collection Hazards

    Never use or install equipment where the potential for combustible fumes or dusts are present without a fire/explosion protection system. • If you are unsure if the product you purchased is correct for your application, call DiversiTech at 1-800-361-3733. 1.5 Safety Stickers •...
  • Page 5: Section 2 - Specifications

    SECTION 2 - SPECIFICATIONS 2.1 Diagram & Description Carbon Canisters Capture Intake Blower Assembly 2.2 Specifications 1. 1.5 HP 120V 1PH AC Blower Assembly, 2. 1200 CFM 3. Choice of 2x50 lbs Carbon canister or 2x75lbs Carbon canister 4. Max operating temperature for the Carbon is 175 degrees Fahrenheit...
  • Page 6 CONTAMINENT ACCUMULATION 15.4” Convenient elastic Parts made of high Twist lock Flange. High porosity virgin High capacity prefilter band easing impact No tools required. extruded •20mm thickness installation of resistant polycarbonate. activated carbon 4 mm. •Low air resistance media prefilter. High quality galvanized Specially designed to •Antibacterial...
  • Page 7: Dimensions

    2.3 Dimensions...
  • Page 8: Section 3 - Setup / Installation

    This saturation point will depend on frequency of use and the concentration of VOC being pulled through the carbon canisters. The Diversitech Canisters are shipped ready for installation with the activated carbon pre-installed. The Carbo system should be as close to the emission source as possible.
  • Page 9: Installation

    3.5 Installation Each machine is wired for correct rotation. Should you need to service the unit’s motor, upon restart, make sure that the motor is turning in the right direct, as marked on the motor. Correct Rotation If not already installed, install the carbon canisters onto the plenum. The canisters are held in place with a safety bar to prevent any accidental tipping.
  • Page 10: Preparing Unit For Operation

    Before plugging unit in to an input power source, make sure that the capture arm is not interfering with adjacent equipment or personnel. • Before collecting fumes, VOC, or other contaminated air, consult your Diversitech representative to make sure that you have the right carbon canister for the intended use.
  • Page 11: Section 5 - Maintenance & Troubleshooting

    SECTION 5 - MAINTENANCE & TROUBLESHOOTING 5.1 To Maintain this Product Safely • Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. • Do not breathe the dust collected from product while changing/cleaning filters or performing maintenance on this product.
  • Page 12: Routine Maintenance Schedule

    5.3 Routine Maintenance Schedule The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the unit is used in severe conditions. Frecuency Manual Reference Pre-Use • Perform pre-use inspection to ensure operating correctly. Daily Inspection •...
  • Page 13: Troubleshooting Procedure

    Motor Operating Operating Air Flow Check Motor Rotation/ Reverse Phase Air Flow Restricted Call for Service Call for Service 1(800)361-3733 1(800)361-3733 support@diversitech.ca support@diversitech.ca Check Filter Load Replace if required Air Flow Restricted Call for Service Unit Operates 1(800)361-3733 Properly support@diversitech.ca...
  • Page 14: Section 6 - Decommissioning

    SECTION 6 - DECOMMISSIONING 6.1 To Decommission this Product Safely • Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. • Do not breathe the dust collected from product while changing/cleaning filters or performing maintenance on this product. •...
  • Page 15: Appendix 1A - Electrical Diagram Manual [120 Vac] Single Phase Power

    APPENDIX 1A - ELECTRICAL DIAGRAM MANUAL [120v] Single-Phase Power ELECTRIC Disconnect power before performing any maintenance on unit, including filter inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. Do not touch live electrical HAZARD parts.
  • Page 16: Appendix 1B - Electrical Diagram Manual [230/460/575V] 3-Phase Power

    APPENDIX 1B - ELECTRICAL DIAGRAM MANUAL [230/460/575v] 3-Phase Power ELECTRIC Disconnect power before performing any maintenance on unit, including filter inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. Do not touch live electrical HAZARD parts.
  • Page 17: Appendix 2 - Maintenance Record

    APPENDIX 2 - MAINTENANCE RECORD DiversiTech Inc. authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance records. MANUFACTURER: DIVERSITECH INC. MODEL N° MOBILE CARBON SERIAL N° FILTRATION UNIT SERVICE LOCATION: CONTROL N° Date Description of Service...
  • Page 18: Appendix 3 - Samples Safety Stickers

    APPENDIX 5 - SAMPLE SAFETY STICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices: The machine is marked with safety stickers in appropriate places to remind the operator of safe working practices.
  • Page 19 NOTES...
  • Page 20 NOTES...
  • Page 21 NOTES...
  • Page 22 NOTES...
  • Page 23 NOTES...
  • Page 24: Limited Equipment Warranty

    LIMITED EQUIPMENT WARRANTY For a period of 2 years from the date of purchase, all Diversitech products are warranted to be free from defects in material, workmanship, and construction, when used in accordance with installation, maintenance instructions, and expressly stated proper use application(s). Diversitech Inc.

Table of Contents