Download Print this page

Canarm 207 Operation Instructions And Parts Manual

200 series; idb series inline duct blowers

Advertisement

Quick Links

200 & IDB SERIES
INLINE DUCT BLOWERS
OPERATION INSTRUCTIONS AND PARTS MANUAL
200 SERIES MODELS: 207, 209, 210, 212, 215, 218
IDB SERIES MODELS: IDB07, IDB09, IDB10, IDB12, IDB15, IDB18

GENERAL SAFETY

Rotating parts, (pulleys, shafts and belts) on fans should not be exposed. Where these components are not protected by ductwork, cabinets
or covers, appropriate guards should be employed to restrict exposure to rotating parts. Access doors should not be opened with the fan
operating to avoid foreign objects being drawn into the system. On initial start-up, a careful inspection should be carried out to ensure no
foreign material is present which could become airborne in the system.
Read installation and operation instructions carefully before attempting to install, operate or service Canarm/Delhi 200 Series or
Canarm/Delhi IDB Series Blowers. Failure to comply with instructions could result in personal injury and/or property damage. Retain
instructions for future reference.
BEFORE YOU BEGIN
Inspect unit for damage, report any shipping damage to carrier. Check all fasteners, re-tighten as required. Rotate the blower wheel by
hand to ensure free rotation. If rubbing occurs, loosen the set screw(s), re-position the wheel to the shaft center, re-tighten set screws.
INSTALLATION
SUSPENSION MOUNTING
Suspend the unit using 4 threaded rods
through the (4) 7/8" clearance holes
located at the top of the unit (see Fig. 1)
or by an angle iron cradle (supplied by
others) under the unit.
BASE MOUNTING
Secure unit through the 4 internal 7/8" clearance holes to a solid base. Ensure unit is level. Complete installation of inlet & outlet ducts.
NOTE: Flexible inlet & outlet duct collars are recommended to minimize vibration transmission.
200_IDB-M-04_16_13
MODEL
MAX. HP
207, IDB07
3/4
209, IDB09
3/4
210, IDB10
1 1/2
212, IDB12
1 1/2
215, IDB15
3
218, IDB18
5
FIGURE 1
SHAFT DIAMETER WEIGHT
3/4"
43 lbs
3/4"
55 lbs
3/4"
65 lbs
3/4"
82 lbs
1"
140 lbs
1"
158 lbs
Page 1 of 4

Advertisement

loading

Summary of Contents for Canarm 207

  • Page 1: General Safety

    Read installation and operation instructions carefully before attempting to install, operate or service Canarm/Delhi 200 Series or Canarm/Delhi IDB Series Blowers. Failure to comply with instructions could result in personal injury and/or property damage. Retain instructions for future reference.
  • Page 2 A rule of thumb suggests that 3/4" of deflection mid-span under medium finger pressure (2-3 lbs.) for every foot of span is appropriate.) MODEL DRIVE TABLE 207 / IDB07 209 / IDB09 210 / IDB10 212 / IDB12...
  • Page 3 200 & IDB SERIES INLINE DUCT BLOWERS FIGURE 2 FIGURE 3 BELT ALIGNMENT BEARING REPLACEMENT ELECTRICAL WARNING ENSURE POWER SUPPLY IS DISCONNECTED & LOCKED OUT PRIOR TO MAKING ELECTRICAL CONNECTIONS. Before connecting the motor to the electrical supply, check the electrical characteristics and wiring instructions as indicated on the motor nameplate or inside the conduit box cover to ensure proper voltage and phase.
  • Page 4 WARRANTY Canarm Ltd. Air Moving Products are guaranteed for a period of one year against manufacturing defects in material and workmanship when operating under normal conditions. Liability is limited to the replacement of defective parts. Labour and transportation costs are not included.

This manual is also suitable for:

209215212210218Idb07 ... Show all