Meden-Inmed GALAXY Installation And Operation Manual

Massage table

Advertisement

Quick Links

INSTALLATION AND OPERATION MANUAL
Manufacturer:
MEDEN - INMED Spółka z o.o.
UL. WENEDÓW 2
75-847 KOSZALIN
POLAND
TEL. + 48 94 3471040
FAX. + 48 94 3471041
GALAXY
Massage Table
Distribution and servicing in Poland:
MEDEN - INMED Spółka z o.o.
UL. WENEDÓW 2
75-847 KOSZALIN
POLAND
TEL. + 48 94 3471040
FAX. + 48 94 3471041

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GALAXY and is the answer not in the manual?

Questions and answers

Summary of Contents for Meden-Inmed GALAXY

  • Page 1 INSTALLATION AND OPERATION MANUAL GALAXY Massage Table Manufacturer: Distribution and servicing in Poland: MEDEN - INMED Spółka z o.o. MEDEN - INMED Spółka z o.o. UL. WENEDÓW 2 UL. WENEDÓW 2 75-847 KOSZALIN 75-847 KOSZALIN POLAND POLAND TEL. + 48 94 3471040 TEL.
  • Page 2: Table Of Contents

    2.1. USAGE 2.2. TECHNICAL DATA 2.3. GALAXY 2 SECTION HEADREST (MERCURY S2.FX, S2.FX-H) 2.4. GALAXY 2 SECTION HEADREST, ADJUSTABLE ARMRESTS (MERCURY S4.FX, S4.FX-H) 5 2.5. GALAXY 2 SECTION BACKREST (MERCURY E-S2.FX, E-S2.FX-H) 2.6. GALAXY 3 SECTION (JUPITER S3.FX, S3.FX-H) 2.7. GALAXY 3 SECTION, ADJUSTABLE ARMRESTS (JUPITER S5.FX, S5.FX-H) 3.
  • Page 3: Introduction

    1. INTRODUCTION Congratulations on a perfect choice of our massage table. GALAXY tables are stable, reliable and easy to use. These features result from careful design, manufacturing methods applied in production and the quality assurance system. Reading and following instructions provided in this manual will ensure safe and long lasting use of our tables.
  • Page 4: Features Of Galaxy Massage Tables

    (class I, rule 12) and are marked with CE mark, as per manufacturer’s declaration GALAXY h y d r a u l i c massage tables [2 section headrest (type: MERCURY mod.: S2.Fx-H, S4.Fx-H, 2 section backrest (type: MERCURY mod.: E-S2.Fx-H), 3 section (type JUPITER mod.: S3.Fx-H, S5.Fx-H) including the relevant accessories] have been manufactured in conformity with essential requirements concerning medical equipment (class I, rule 1) and are marked with CE mark, as per manufacturer’s...
  • Page 5: Galaxy 2 Section Headrest (Mercury S2.Fx, S2.Fx-H)

    2.3. GALAXY 2 SECTION HEADREST (MERCURY S2.Fx, S2.FX-H) Head section inclination angle adjustment from 0 to +40 deg. Length of the head section 46 cm Head section declination angle adjustment from 0 to -70 deg. Length of the leg section 155 cm 2.4.
  • Page 6: Galaxy 3 Section (Jupiter S3.Fx, S3.Fx-H)

    Length of the leg section 101 cm CAUTION! This manual covers all types of the GALAXY massage tables and not all information and drawings will be relevant to your own massage table. The manufacturer reserves itself a right to apply changes to the product not included in this version of manual without reducing its functionality or lowering safety requirements.
  • Page 7: Design And Functions

    The Galaxy has a foot- operated height adjustment all-around switch frame in standard. The Galaxy has the frame with 2 rollers and 2 in height adjustable feet in standard (F0 frame). The Galaxy has 4 directable, retractable wheeling system with central brake as option (F4 frame).
  • Page 8: Additional Accessories

    3.2. Additional accessories Each GALAXY table is provided with a breathing hole in head section and has rails for fastening the stabilizing belts in the leg section. Additionally, the tables may be equipped with the following accessories: - stabilizing bolsters and belts...
  • Page 9: Safety Means

    1. Select the place for the use of the table with a minimum of 80 cm clearance on each side of the unit. Figure 3 - Recommended positioning of the GALAXY massage table CAUTION! W hen positioning or repositioning the table, pay special attention to ensure that there are not any objects below the lower frame of the table.
  • Page 10: Operating The Table

    6.2. Height adjustment – raising (lowering) of the bed Height adjustment in electrical GALAXY tables is done by means of a foot-controlled all-around switch frame located at the bottom of the table. To lift the table, push the frame in the direction of the head-rest / back-rest (marked as B in fig.
  • Page 11: Adjustment Of The Adjustable Section Inclination/Declination

    Moving elements pose danger by creating pinch points. 6.4. Moving the table 1. GALAXY table with the F4 frame type has a foot lever (see C in fig. 4) which can be set in two positions: - WORK (A), with the table resting on its feet, which can be adjusted for levelling (by screwing the foot in and out –...
  • Page 12: Access Control (Electric Models Only)

    Do not attempt to move the table with a patient on it! 6.7. Access control (electric models only) The GALAXY tables contain access control feature which blocks the unauthorized operation of the hi- lo height adjustment. Removing the key from the socket ❶ will cause the LED light ❷ to blink (0,7x/sec) and the table’s actuator is blocked.
  • Page 13: Maintenance

    Phillips screwdriver, hex keys (no 4 and 5) and flat spanners (10 and 19). Report all loose connections that cannot be removed to the manufacturer’s authorized service and cease using the table until the cause of the problem is removed. 2014-05-19 GALAXY table - Manual En Page 13 of 15...
  • Page 14: Checking The Gas Springs

    7.3. Checking the gas springs GALAXY tables are equipped with gas springs for easy adjustment of h e a d section inclination (all models) and leg section inclination angle (only 3 section models). To ensure proper performance of the gas springs check the springs visually for leaks every 3 months. Any performance deficiency or leak must be reported to producer’s technical service...
  • Page 15: Warranty Card

    12 month warranty. The warranty repairs can only be made by Meden-Inmed’s authorised service teams. 2. Meden-Inmed is responsible for any faults whether in quality or quantity only if they have been reported within 2 days following the delivery. It is the buyer’s responsibility to inform Meden- Inmed of such faults within the period of 2 days after delivery.