TECHNICAL FEATURES / SPECIFICHE TECNICHE
MOUSE 09
Input Voltage / Alimentazione
Current Drain / Consumo (Alarm / Stand-By)
Tipical Voltage / Tensione nominale
Coverage / Portata Massima
Aperture Angle / Angolo di Apertura
PIR / Piroelettrico
Lens / Lente
Microwave frequency / Frequenza Microonda
Grado IP / IP Grade
Alarm period / Durata allarme
Alarm Type / Tipo allarme
Anti-opening / Antiapertura
Back Tamper / Antistrappo
Pulse counter / doppio impulso
Alarm contact
Tamper Switch / Contatto di Tamper
Operating Temperature / Temperatura di esercizio
Storage Temperature / Temperatura di stoccaggio
RFI Protection / Protezione RFI
Walk Test LED (MW and PIR)
Housing / Cover
Dimensions / Dimensioni
Meets the requirements: EN 50131-2-2 Grade 2 EN 50131-2-2 Class 2
L'installazione deve essere eseguita a regola d'arte da personale specializzato.
Il produttore declina ogni responsabilità nel caso in cui il prodotto venga manomesso da persone non autorizzate.
Si raccomanda di verificare il corretto funzionamento del sistema d'allarme almeno una volta al mese, tuttavia un sistema di allarme elettronico
affidabile non evita intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che tali situazioni si verifichino.
Installation must be carried out following the local installation norms by qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized repairs are made to the product/system.
It is recommended to test the operation of the alarm product/system at least once a month. Despite frequent testing and due to, but not limited to,
any or all of the following: tampering, electrical or communication disruption or improper use, it is possible for the product/system to fail to prevent
burglary, rubbery, fire or otherwise. A properly installed and maintained alarm system can only reduce the risk that this happens.
www.amcelettronica.com
9 to 15 V
17 mA / 24 mA @ 13.8V
13.8V
15mt
90°
PIR - 2 Elements / 2 Elementi
(29 Patterns on 3/5 levels)
9.3GHz / 9.9 GHz / 10,525 GHz
IP 30
2 sec.
AND
-
100 mA - 60 V -16 Ω
Max 40 mA - 30 Vdc
From -10 °C to +55 °C
From -20°C to +55 °C
30 V / m (80 /2000 MHz)
ABS
110 x 60 x 46 mm
Mouse 09
4