Eriez HMDA Installation, Operation And Maintenance Instructions

Heavy media permanent magnetic wet drum separator

Advertisement

Quick Links

Installation, Operation
and Maintenance
Instructions
ERIEZ MAGNETICS
WORLD AUTHORITY IN ADVANCED TECHNOLOGY FOR MAGNETIC, VIBRATORY and INSPECTION APPLICATIONS
HEAVY MEDIA
PERMANENT
MAGNETIC
WET DRUM
SEPARATOR
HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506–1402 U.S.A.
Heavy Media Permanent Magnetic Wet Drum Separator
MMPM-470G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HMDA and is the answer not in the manual?

Questions and answers

Summary of Contents for Eriez HMDA

  • Page 1 Installation, Operation and Maintenance Instructions HEAVY MEDIA PERMANENT MAGNETIC WET DRUM SEPARATOR ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506–1402 U.S.A. WORLD AUTHORITY IN ADVANCED TECHNOLOGY FOR MAGNETIC, VIBRATORY and INSPECTION APPLICATIONS Heavy Media Permanent Magnetic Wet Drum Separator...
  • Page 2 Eriez Wet Drum Separators are designed and ruggedly built for long, hard service – but certain installation, operating and maintenance procedures must be observed.
  • Page 3: Table Of Contents

    Table of Contents ERIEZ MODEL HMDA WET DRUM MAGNETIC SEPARATOR GENERAL DESCRIPTION ..................4 INSTALLATION ..................... 5 General ......................5 Adjustments ..................... 5 OPERATION ......................6 Adjustments ..................... 6 Style I - Concurrent ..................7 Style II - Counter-Rotation ................7 Style III - Self-Leveling ..................
  • Page 4: General Description

    General Description Installation HMDA Wet Drum Separators are designed primarily GENERAL for use in heavy media system recovery circuits Use care when lifting the separator to avoid damage to the equipment. for recovery of magnetite or ferrosilicon. They are designed to be fed a slurry or “pulp” of finely divided particles suspended in water.
  • Page 5: Installation

    Installation Tank And Frame Adjustment The tank and frame assembly should be checked ADJUSTMENTS across the width and length to make sure it is level. Magnet Adjustment If not, shims should be placed between the frame The drum and magnet positions are set at the factory pads and supporting foundation.
  • Page 6: Operation

    An external water level overflow weir is provided The magnet setting as described above should result on HMDA Models. A proper water level can be in a satisfactory point of discharge; however, slight maintained when water is overflowing the weir...
  • Page 7: Style I - Concurrent

    It is very important in this type of separator that the and maintenance. proper water level be maintained. Overflow volume The Eriez Self-Leveling tank has no discharge should be from 40% to 50% of total tailings flow. Feed spigots to adjust. The tank level is controlled by to the separator must remain constant to insure proper removable weir bars on the discharge side of the tank.
  • Page 8: Maintenance

    Set of Sprockets Set of Bearings Chain Set of Seals Eriez and Eriez Magnetics are registered trademarks of Eriez Manufacturing Co, Erie, PA ©2012 Eriez Magnetics All Rights Reserved World Authority in Advanced Technology for Magnetic, Vibratory and Inspection Applications Headquarters: 2200 Asbury Road, Erie, PA 16506-1402 U.S.A.