  • Page 1 230 V actuator Instructions for Use For Fonterra radiant heating and cooling Model 1249 en_INT...
  • Page 2 230 V actuator 2 from 9...
  • Page 3: Table Of Contents

    Table of contents Table of contents About these instructions for use Target groups Labelling of notes About this translated version Product information Intended use Product description 2.2.1 Functions 2.2.2 Overview and description of component 2.2.3 Technical data Handling Transport and storage Mounting the actuators Care tips Disposal...
  • Page 4: About These Instructions For Use

    This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
  • Page 5: About This Translated Version

    About these instructions for use About this translated version This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.
  • Page 6: Product Information

    Product information 2 Product information Intended use The actuator is suitable for use in connection with the following basic units models: 1246 1246.1 1247 1247.2 1247.3 1247.6 Since the combination with electronic components by other manufac‐ turers has not been tested, proper function cannot be ensured in this case.
  • Page 7: Technical Data

    Product information Installation dimensions Fig. 2: Installation dimensions in mm 2.2.3 Technical data Operating voltage 230 V AC, 50/60 Hz Switch-on current 140 mA / 200 ms Operating current 9 mA Operation cable Opening and closing time approx. 5 min. Displacement >...
  • Page 8: Handling

    Handling 3 Handling Transport and storage Observe the following with transport and storage: Avoid heavy blows and vibrations. Store the components in a clean and dry place. Do not remove the components from the packaging until immedi‐ ately before use. Mounting the actuators Mounting preparation DANGER!
  • Page 9: Care Tips

    Handling Care tips NOTICE! Damage due to water in the casing The device is live. Contact with water will damage the device. – Avoid any contact of the devices with water. Care tips Wipe the surfaces down with a moist cloth. Disposal Separate the product and packaging materials (e.