Download Print this page

Excella E-2000 Operating Manual

Door sensor

Advertisement

Quick Links

6) Faults Comparison Table:
Phenomenon of Fault
No response in RX (LED)
LED green light in RX is
flashing slowly and regularly
The light curtain is not
obstructed, but both the
LED green and red lights in
RX are on.
LED lights in RX are normal, but
the door doesn"t open although
the light curtains are obstructed.
Red indicator light in Control
box is off.
When the door is closing, the
doors jump and re-open.
7) Packing List:
Item number
Item Name
Control box
1.
2.
Cable (4m)
3.
Transmitter (TX)
4.
Receiver (RX)
5.
Instruction book
6.
25mm X 25mm cable clip
7.
M3 X 25 Screw
8.
M3 Nut
9.
90mm Nylon ties
Faults Analysis
Cables no connection; or control box no power;
or cables were snapped
System is in status of timeout; or the broken
diode will be ignored.
Check if there are other infrared equipments
around; if the windows of TX and RX are dirty;
if the windows are shined by glare; if the
cables are bad, or the light curtains damaged.
Wrong connection of control box, or relay output
is damaged, or the triode in RX is damaged.
Wrong connection in control box, or no power; or
connection is not tigtt; or control box damaged.
Not reasonable when wiring; or conductive
earth of the control box is not well
Quantity
1 PC
2 PC
1 PC
1 PC
1 PC
6 PC
10 PC
10 PC
6 PC
OPERATING MANUAL FOR DOOR SENSOR
1) Specification of Transmitter (TX) and Receiver (RX):
Model
Scanning beams
Detecting
Response time
Vertical: 20mm; Horizontal: 3mm
Displacement at 0mm
Adaptive environment
Size (mm)
1. The green LED on the Receiver indicates the
System Hint
normality of the sensors.
Slow flashing means it is in condition of timeout.
2. The red LED light in the Receiver indicates the
states of the sensors. If it is off, that means the
sensor is normal; If it is on or flashing, that means
the light curtain is obstructed or it arises errors.
2) Specification of Control Box (Power Supply):
Control Box
External Dimension
Material
185-300V AC, + 10%, 50/60 Hz
Input Voltage
Relay Output Type
Power Consumption
Relay Contact Rating
Lifetime of Relay
Short Circuit Protection
System Hint
Give buzzer sound once interrupted.
(Buzzers are optional)
E L E C T R O N I C S
Tel.:
+91-22-21029911
!
Fax.:
!
E-mail:
sales@excellaelectronics.com
!
Web:
www.excellaelectronics.com
E-2000
154 beams
0 ~ 4000mm
< 90ms
+
+
Light immunity
>
100000 lux
9 X 24 X 2000
P220-S (With Buzzer)
178mm X 67mm X 39.5mm
Steel & Aluminium
COM, 1NO, 1NC
4VA
250VAC, 7A or 30VDC, 7A
> 1000000 times
YES
+91-22-21029922

Advertisement

loading
Need help?

Need help?

Do you have a question about the E-2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Excella E-2000

  • Page 1 1) Specification of Transmitter (TX) and Receiver (RX): LED green light in RX is System is in status of timeout; or the broken flashing slowly and regularly diode will be ignored. E-2000 Model Check if there are other infrared equipments The light curtain is not 154 beams Scanning beams around;...
  • Page 2 4) The states of indicator lights on Receiver (RX): 3) Door Sensor Model E-2000 INSTALLATION The RX detector has two LED lights for troubleshooting: Green LED Red LED Possible Cause POWER SUPPLY UNIT: CONNECTION: MODEL P20 : INPUT 220V AC...