Summary of Contents for GUTMANN mega macs 42 SE

  • Page 1 42 SE Quick Start Guide QSMM42SEV5200EN0917S0 460 986-00 / 09.17...
  • Page 2: Table Of Contents

    1 About this Quick Start Guide............4 Reading the Manual ..............4 2 Safety Precautions ................. 5 Safety Precautions – Risk of Injury..........5 Safety Precautions for the mega macs 42 SE .........6 3 Product Description ............... 7 Delivery Contents................7 Intended Use.................8 Using the Bluetooth Function ............9...
  • Page 3 42 SE Table of Contents 6 Configuring the Device ...............17 Configuring the Bluetooth Adapter ..........17 7 Working with the Device ............18 Symbols..................18 Diagnostics .................18...
  • Page 4: About This Quick Start Guide

    Reading the Manual You can find the manual with detailed information about the use of your mega macs 42 SE on the homepage of Hella Gutmann www.hella- gutmann.com/de/workshop-solutions/diagnose. This page provides the current download versions of the manuals and quick start guides as well as other valuable product leaflets for optional accessories and products of Hella Gutmann, which can support you in your daily work.
  • Page 5: Safety Precautions

    42 SE Safety Precautions Safety Precautions – Risk of Injury 2 Safety Precautions Safety Precautions – Risk of Injury When working on the vehicle, there is a risk of injury through rotating parts or rolling of the vehicle. Therefore observe the following: •...
  • Page 6: Safety Precautions For The Mega Macs 42 Se

    Connect the device exclusively according to user manual. • Keep the device away from fluids such as water, oil or gasoline. The mega macs 42 SE is not waterproof. • Protect the device from strong impacts and do not drop it.
  • Page 7: Product Description

    Bluetooth adapter USB cable for connecting the DT VCI to the device USB cable for connection to a PC 1 each Power adapter and cable for the mega macs 42 SE Vehicle charging cable HGS data carrier Quick Start Guide...
  • Page 8: Intended Use

    Intended Use The mega macs 42 SE is a mobile diagnostic device for detecting and rectifying faults in automotive electronic systems. It uses a diagnostic interface to establish a connection to the automotive electronics and to provide access to descriptions of the vehicle system.
  • Page 9: Using The Bluetooth Function

    The device is not suitable for repairing electrical machines and tools or home electrics. Diagnostic devices from other manufacturers will not be supported. If the device is used in a way not authorized by Hella Gutmann, the safety of the device may be influenced. Using the Bluetooth Function The terms of use of the Bluetooth function may be restricted or prohibited through law or corresponding legal regulations in certain countries.
  • Page 10 Navigate with the cursor in menus or functions. ENTER Confirm a function, input or menu. Call up information on the communication parameters. In case of a complaint, Hella Gutmann Solutions GmbH requires this information to detect and repair the fault. Leave the HGS menu with ESC. PRINT Here you can use various functions such as: •...
  • Page 11: Connections Of The Mega Macs 42 Se

    42 SE Product Description Connections of the mega macs 42 SE Connections of the mega macs 42 SE D D e e s s i i g g n n a a t t i i o o n n...
  • Page 12 42 SE Product Description DT VCI Connections 3.7.1 Meaning of the Flashing Frequencies S S t t a a t t u u s s d d i i s s p p l l a a y y...
  • Page 13: Installation Of The Hella Gutmann Drivers Package

    Windows administrator rights Installation of the Hella Gutmann Drivers Package To obtain all the data about the related vehicle provided by Hella Gutmann, the device requires a permanent online connection and the installed driver package Hella Gutmann Drivers. To keep the connection costs down, Hella Gutmann recommends a DSL connection and a flat rate.
  • Page 14: Putting Into Operation

    NOTICE At the first start-up of the device and after every software update, you need to confirm the general terms and conditions (GTC) of Hella Gutmann Solutions GmbH. Otherwise, certain device functions will be unavailable. To switch on the device: 1.
  • Page 15: Entering Company Data

    42 SE Putting Into Operation Entering Company Data Entering Company Data NOTICE You cannot start working with the device after having entered the company data. Proceed as follows to enter the company data: 1. Select and confirm >Name 1<.
  • Page 16 Putting Into Operation mega macs 42 SE Switching Off the Device 2. Observe the confirmation prompt. 3. Switch off the device with ENTER. Abort the procedure with ESC. The device is switched off.
  • Page 17: Configuring The Device

    Configure all interfaces and functions under >Settings< in the main menu. Configuring the Bluetooth Adapter Here you can configure the Bluetooth adapter. The integrated Bluetooth module enables a wireless connection to a PC on which the driver package Hella Gutmann Drivers is installed. 6.1.1 Searching for the Bluetooth Adapter NOTICE...
  • Page 18: Working With The Device

    Working with the Device mega macs 42 SE Symbols 7 Working with the Device Symbols 7.1.1 Symbols in the Header I I c c o o n n s s D D e e s s i i g g n n a a t t i i o o n n Battery charging status The battery state of charge is indicated here.
  • Page 19 42 SE Working with the Device Diagnostics • Trouble code reading • Parameter readout • Actuator test • Service reset • Basic setting • Coding • Test function Proceed as follows to prepare vehicle diagnostics: 1. Select the requested vehicle under >Diagnostics< in the main menu.
  • Page 20 42 SE Working with the Device Diagnostics 2. Insert the DT VCI into the vehicle's diagnostic port. Both LEDs of the DT VCI flash. The DT VCI is ready for operation. Now you can select the type of diagnostics.
  • Page 21 42 SE Working with the Device Diagnostics 2. Insert the DT VCI into the vehicle's diagnostic port. Both LEDs of the DT VCI flash. The DT VCI is ready for operation. 3. Select the requested diagnostics. 4. Observe the information window, note window and instruction window as applicable.
  • Page 22 Notes mega macs 42 SE...
  • Page 23 42 SE Notes...
  • Page 24 HELLA GUTMANN SOLUTIONS GMBH Am Krebsbach 2 79241 Ihringen GERMANY Phone: +49 7668 9900–0 Fax: +49 7668 9900–3999 info@hella-gutmann.com www.hella-gutmann.com © 2017 HELLA GUTMANN SOLUTIONS GMBH 1 STUECK/PIECE(S) ���� ��� �������� 9XQ 460 986-001 Made in Germany...

Table of Contents