Summary of Contents for Buck BUCK-Libra Plus LP-5

  • Page 1 BUCK-Libra Plus™ LP-5 ODEL NSTRUCTION ANUAL A.P. BUCK, INC. • • 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA • Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 apbuck@apbuck.com • www.apbuck.com 7101 Presidents Drive • Suite 110 • Orlando, FL 32809 Tel: (407) 851-8602 • Fax: (407) 851-8910...
  • Page 2 23 23...
  • Page 3 Table of Contents Section Description Page Quick Start Tutorial……………..……….………...5 Design and Basic Features….…………….……...6 Pump Specification.……. ….…………....7-8 Operational and Menu Displays…………….….9-11 Filter Cassette Sampling………………………….12 Bubble and Impingers Sampling………………...13 Low Flow Tube Sampling………………………...14 Battery Chargers and A/C Power Supply……….15 Parts and Accessories…………………………….17 Warranty &...
  • Page 4: Owner Registration

    OWNER REGISTRATION Please complete and fax this card to 407-851-8910 to properly register your unit OR register on line at www.apbuck.com on the service and support page. Contact Name Company Address City State Zip Code Country Phone Number Email Address Purchased From Purchase Date Important: List all products purchases and corresponding serial numbers:...
  • Page 5 Section 1 Buck-Libra Plus Series Quick Start Guide Note: Connect a representative sampling filter cassette using 1/4 inch tubing to the pump prior to setting Flow Rate for optimal per- formance Main Display Setting the Flow rate 1. Connect sampling filter with a hose to the pump.
  • Page 6: Service Information

    Section 2 SERVICE INFORMATION Design and Features For all work not covered under warranty, A.P. Buck, Inc. will repair The main purpose of this battery-operated personal sampling any instrument for the cost of parts and labor as quoted. If major pump is to draw contaminants from an air sample into, onto components must be replaced, A.P.
  • Page 7: Warranty

    Time, Volume Collected, Timer ment supplied by us. Flow Fault Displays: Flow Fault, or Filter Off A.P. Buck, Inc. reserves the right to make changes at any 5 Menu Displays: Adjust Flow, Clear Data, Calibration, time, without notice, in prices, colors, materials, specifica- Timer, Key Pad Lock option tions, and models;...
  • Page 8: Parts And Accessories

    109030). Desired flow may be precisely adjusted for flows of 5 A/C adapter/ overnight Charge 110 VAC or 240 VAC to 800 cc/min. with the mini- BUCK Calibrator™ and a screw- driver using the tube holder’s built-in adjustable screw. Approvals CE EMC Directive (EMCD) 89/336/EEC 7.
  • Page 9 Section 4 A/C Power Supply (continuous sampling) The Standard Battery Charger for BUCK pumps, will supply enough power to operate the Libra Plus Pump continuously while sampling. Simply plug the charger into the battery pack into 120 VAC outlet and turn the pump on to sample.
  • Page 10 When the green light turns ON and Yellow turns OFF, the batteries are fully charged. Standard Charger The Standard Charger is designed to charge the BUCK PUMP NiMH battery single pack in 16 hours. The connection is made through the same charge port on the rear bottom of the battery pack.
  • Page 11 Pressure Mode and turn on the pump motor to operate at a set speed. 2. Using the mini-BUCK Calibrator M1 (0.1 to 300 cc/min.) or M5 (1 to 6000 cc/min.), measure the flow through the adsorbent tube as shown above. Use a screw driver to adjust the flow to the desired rate.
  • Page 12: Main Display

    BUCK-Libra Series Pumps will operate at 4. Measure flow, if it matches +/- 5% of setting, press the ON/ the pre-selected flow.