Download Print this page

Daitron MFS50-12 Instruction Manual

Mfs50 series

Advertisement

Quick Links

Prior to Use
・ Please read this instruction manual carefully before using the product.
・ Be sure to use the product as directed in these precautions.
Warning
・ Detach neither remodeling nor the cover of the product.
This product contains components with high voltage or high temperature.
・ To avoid electric shock or burns, do not touch these components.
・ Keep your face and hands away from the activated product.
Unexpected trouble may occur, causing injury.
Caution
・ This power supply unit is intended to be used with general or commonly used
electronic equipment.
・ Do not operate this product in over-charged current or short-circuit
conditions for more than 10 sec.
Such conditions may cause damage and electrical insulation failures.
・ Avoid actions causing shock such as dropping to this product.
1.Terminal description
・ Before connecting the input and the output , make sure that the input is shut off.
・ Please use less than 5A for each output terminal pin.
・ Connect the FG terminal with the earth terminal of the device or the equipment.
・ Please use applicable connectors for each pin.
Also please use suitable crump tool recommended by manufacturer
・ Wire for the output and the input separately. The noise-proof improves.
Pin #
1
CN101
2
3
4
5
CN501
6
7
8
CN502
9
10
3
2
1
Terminal description
L
Input Terminal (L)
N
Input Terminal (N)
Frame Ground
+
Output Terminal (+)
+
Output Terminal (+)
-
Output Terminal (-)
-
Output Terminal (-)
+R
Remote Control Terminal (+)
-R
Remote Control Terminal (-)
Output Voltage Adjustment Potentiometer
MFS50 Series
Misuse may cause electric shock, fire or failure.
Housing
VHR-5N
(Manufacturer:
JST)
VHR-
4N(Manufacturer:
JST)
XHP-2
(Manufacturer:
JST)
10
7
4
8
9
Instruction Manual
Connector
BVH-21T-P1.1
or
SVH-21T-P1.1
BXH-001T-P0.6
or
SXH-001T-P0.6

Advertisement

loading

Summary of Contents for Daitron MFS50-12

  • Page 1 MFS50 Series Instruction Manual Prior to Use ・ Please read this instruction manual carefully before using the product. ・ Be sure to use the product as directed in these precautions. Misuse may cause electric shock, fire or failure. Warning ・ Detach neither remodeling nor the cover of the product. This product contains components with high voltage or high temperature.
  • Page 2 2.Function explanation Input Voltage Remote ON/OFF circuit ・ Input voltage range is single phase alternating current ・ You can turn on/off while applying input. 85~264Vac(47~63Hz). ・ You can apply voltage to the RC pin. ・ We recommend that you do not use this power supply unit outside of it's normal intended use in CN502 Connector order to avoid any damage or malfunctions.
  • Page 3 ( c ) ( d ) CN101 CN101 CN10 CN101 Power derating curve ・ There are no difference by mounting directions above (3-1). ・ Please refer to the following derating curve. MFS50-12、-15、-24、-30、-48 MFS50-5 Load Load Ambient Temperature (℃) Ambient Temperature (℃)

This manual is also suitable for:

Mfs50-15Mfs50-24Mfs50-30Mfs50-48Mfs50-5