Philips RS-232 to Pelco RS-422 Code Translator
The code translator is designed to convert Philips RS-232 camera control code to Pelco RS-422 code
for a single P/T/Z. Only camera commands for the address matching the Address Selector switches
will be converted.
A test mode sends a continuous square movement pattern to the P/T/Z so the wiring and addressing
between the translator and the P/T/Z can be checked without a Philips controller.
Address Selector
Selects the camera
address. The valid ad-
dress range is 1~999
The removable mounting
clip can be snapped onto a
din rail or screwed to a
panel or wall.
Sennetech, Inc. 3990 Capital City Blvd. Lansing, MI 48906 Ph (517) 321-1905 Fax (517) 321-8750
SCT-100-Philips232-Pelco
Rx
Error
Indicator
Indicator
Flashes when
Flashes on input
there is data on
error.
the input lines.
Stays on if the
input lines are
reversed.
Rx
Com
Data
Input
Connect power to the AC
inputs. Do not connect
power wires to the Gnd.
SPECIFICATIONS
Size:
4.5" x 3.5" x 1.25"
Weight:
0.5 lb
Power:
9Volt to 15Volt AC or DC at 75ma
(Optional 24vac operation)
Environmental: Indoor use only
Status
Tx
Indicator
Indicator
Lights if an
Flashes when
invalid address
camera control
code is sent.
is selected.
_
+
AC
AC
Data
Power
Output
Configuration Switches
Switch 1: Pelco Output Code Type
Up:
Pelco "P" code
Down:
Pelco "D" code
Switch 2: "P" Code Baud Rate
Up:
9600 Baud
Down:
4800 Baud
Switch3: "P" Code Parity
Up:
Even Parity
Down:
No Parity
Switch 4: Not assigned
Up:
Autospeed Enabled
Down:
Autospeed Disabled
Switch 5: Output Camera Address
Up:
Set camera to #1
Down:
Output address = Input
Switch 6: Output test code
Up:
Output test pattern On
Down:
Output test pattern Off
Removable edge connector
Insert a small screwdriver in
the upper slot to force open
the wire clamp. Push all the
way in to open fully. Place
stripped wire end(s) in the
open clamp and withdraw
screwdriver.

Advertisement

loading
Need help?

Need help?

Do you have a question about the SCT-100-Philips232-Pelco and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sennetech SCT-100-Philips232-Pelco

  • Page 1 Size: 4.5" x 3.5" x 1.25" Weight: 0.5 lb Power: 9Volt to 15Volt AC or DC at 75ma (Optional 24vac operation) Environmental: Indoor use only Sennetech, Inc. 3990 Capital City Blvd. Lansing, MI 48906 Ph (517) 321-1905 Fax (517) 321-8750...
  • Page 2 Pelco Code Type Both "P" code and "D" code are supported. Baud Rates If "P" code is selected, the output can be either 4800 baud or 9600 baud. If "D" code is selected, the output is fixed at 2400 baud. Parity If "P"...