SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD S1UA-DC06-ANT3 User Manual

Rf wireless receiver

Advertisement

Quick Links

RF Wireless Receiver (Model 0020197 S1UA-DC12-ANT3)

Package Include:

1 x Receiver: S1UA-DC12-ANT3
1 x User manual

Feature:

Application: It can be used in industry automation, agriculture automation and home automation, such as factory, house, farm, pasture, vehicle, ship,
offshore operation, aerial vehicle, field call, etc. It can remote control equipments on land, water and air, such as remote control lights, sirens, locks,
motors, fans, winches, blinds, linear actuators, doors, windows, electric solenoid valves, security alarm, business signs and various devices.
Wireless control, easy to install.
Waterproof: The receiver has waterproof case and waterproof connector, it can be installed outdoors.
Relay Output: This receiver is relay output, it can be used to operate both DC and AC equipments. The terminal is NO / NC (normally open / normally
closed), which serves as a switch. That means you should also connect a separate power supply to it.
With
wired control
terminals: You can connect sensors, limit switches, manual switches or external devices to control the receiver.
With the external antenna, it can have a further working range.
Design with low-power and high-speed CMOS technology.
You can turn on/ off the receiver with transmitter (remote control) from any place within a reliable distance.
Wireless RF signal can pass through walls, floors, doors or windows.
With reverse power protection and over current protection.
Reliable control: The receiver only works with the transmitter which use same code.
One/several transmitters can control one/several receivers simultaneously.
You can use two or more units in the same place.

Receiver Parameters:

Model No.: S1UA-DC06-ANT3 / S1UA-DC09-ANT3 / S1UA-DC12-ANT3 / S1UA-DC24-ANT3
Power Supply (Operating Voltage): DC6V (S1UA-DC06-ANT3), DC9V±1V (S1UA-DC09-ANT3), DC12V±1V (S1UA-DC12-ANT3), DC24V±2V
(S1UA-DC24-ANT3)
Output: Relay output (Normally open and normally closed)
Working Voltage Range of Relay: AC110~240V or DC0~28V
Working Frequency: 315MHz / 433MHz
Channel: 1 CH
Control Modes: Toggle, Momentary, Latched
Static Current: ≤6mA
Maximum Working Current: 10A
Wire range:22~11AWG
PCB size: 88mm x 80mm x 18mm
Case size: 115mm x 90mm x 55mm
Work with Fixed code transmitters or Learning code transmitters.

Matching Transmitters:

The receiver can work with different transmitters, such as model C-1 / C-2 (100M), CWB-1 / CWB-2 (50M, waterproof), CP-1 / CP-2/CV-2 (500M), or
CB-1 / CB-2 (1000M) etc.
When you set the receiver in toggle or momentary mode, it should work with single button transmitter, such as model C-1 (100M), CWB-1 (50M,
waterproof), CP-1 (500M), or CB-1 (1000M) etc. When you set the receiver in latched mode, it should work with two buttons transmitter, such as
model C-2 (100M), CWB-2 (50M, waterproof), CP-2 (500M), CV-2 (500M), or CB-2 (1000M) etc.

Working Range:

Super long range, with a transmitter (such as CB-2) to form a complete set, the maximum working distance can reach 2000M in an open ground.
The maximum working distance is a theoretical data, it shall be operated in an open ground, no barriers, no any interference. But in the practice, it will
be hindered by trees, walls or other constructions, and will be interfered by other wireless signals. Therefore, the actual distance may not reach this
maximum working distance.

External Telescopic Antenna:

Length of external telescopic antenna: 108mm / 445mm (stretch)
With SMA connector.
If you stretches the external telescopic antenna, it can have a further working range.
Usage (with the transmitter CB-2):
The receiver can be used to control both DC 0~28V and AC 110~240V equipments.
Notice: The receiver is relay output, not DC/AC power output. Initial state of relay output terminals: Terminals "NO" and "COM" are Normally Open;
Terminals "NC" and "COM" are Normally Closed.

Wiring:

If you want to control a DC 12V lamp, do as following:
1) Connect the positive pole of DC power supply to terminal "L / +", and connect the negative pole of DC power supply to terminal "N / -".
2) Connect terminal "NO" to the positive pole of DC power supply, connect terminal "COM" to the positive pole of DC lamp, and connect the negative
pole of DC lamp to the negative pole of DC power supply.
If you want to control an AC 220V lamp, do as following:
SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
Http://www.carymart.com
E-Mail: sale@carymart.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S1UA-DC06-ANT3 and is the answer not in the manual?

Questions and answers

Summary of Contents for SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD S1UA-DC06-ANT3

  • Page 1 You can use two or more units in the same place. Receiver Parameters: Model No.: S1UA-DC06-ANT3 / S1UA-DC09-ANT3 / S1UA-DC12-ANT3 / S1UA-DC24-ANT3 Power Supply (Operating Voltage): DC6V (S1UA-DC06-ANT3), DC9V±1V (S1UA-DC09-ANT3), DC12V±1V (S1UA-DC12-ANT3), DC24V±2V (S1UA-DC24-ANT3) Output: Relay output (Normally open and normally closed)
  • Page 2 Operation: Press and hold the button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all stored codes have been deleted successfully. SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD Http://www.carymart.com E-Mail: sale@carymart.com...
  • Page 3 Signal LED Signal LED Button Button Status LED Status LED Relay Relay NO1 COM1 NO1 COM1 DC Lamp AC Lamp AC Power supply DC Power supply DC Power supply DC Power supply SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD Http://www.carymart.com E-Mail: sale@carymart.com...

This manual is also suitable for:

S1ua-dc12-ant3S1ua-dc09-ant3S1ua-dc24-ant3

Table of Contents