DC2412-UPS
Benutzerhandbuch
DC2412-UPS-LD
User's Manual
UPSIC-1205
UPSIC-2403
Deutsch
English

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC2412-UPS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bicker Elektronik DC2412-UPS

  • Page 1 DC2412-UPS Benutzerhandbuch DC2412-UPS-LD User’s Manual UPSIC-1205 UPSIC-2403 Deutsch English...
  • Page 2 DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 DC2412-UPS | DC2412-UPS-LD UPSIC-1205 | UPSIC-2403...
  • Page 3: Table Of Contents

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 Bestimmungsgemäße Verwendung ........4 Technische Zeichnung und Steckerbelegung......4 Technische Daten................. 5 Einbau .................... 5 Inbetriebnahme ................5 DC2412-UPS-LD ..................5 DC2412-UPS ....................6 UPSIC-1205/UPSIC-2403................ 6 Schutz gegen Überspannung („Load Dump“-Funktion) ..6 Ladezeit der Superkondensatoren ...........
  • Page 4: Bestimmungsgemäße Verwendung

    Haftung übernommen werden. Hinweise auf vorhandene Fehler, Verbesserungsvorschläge und Kritik nehmen wir dankbar entgegen. Die bestimmungsgemäße Verwendung der DC/DC-Wandler DC2412-UPS und DC2412- UPS-LD besteht in der Gleichspannungswandlung von 24 V DC auf 12 V DC sowie Überbrückung von kurzen Spannungsausfällen. Die bestimmungsgemäße Verwendung der USV-Systeme UPSIC-1205 und UPSIC-2403 besteht aus der Überbrückung von kurzen...
  • Page 5: Technische Daten

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 J301 Steckerbelegung Connector J301 I 2 C RS232 01 DCD signal 10 SMB alert 02 DSR signal (Low = Cap >90 %; 11 GND High = Cap <90 %) 12 XSDA I²C 03 NC...
  • Page 6: Dc2412-Ups

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 5.2 DC2412-UPS Nach Anlegen der Versorgungsspannung läuft das Gerät an, der Ausgang liefert 12 VDC und die Supercaps werden geladen. 5.3 UPSIC-1205 / UPSIC-2403 Nach Anlegen der Versorgungsspannung (UPSIC-1205 V > 11.5 V, UPSIC-2403 V >...
  • Page 7: Ladezeit Der Superkondensatoren

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 7 Ladezeit der Superkondensatoren Der Hauptanteil des Stromes wird auf den Ausgang übertragen, ein Teil wird zum Laden der Superkondensatoren verwendet. Bei niedrigen Lasten steht entsprechend mehr Ladestrom zur Verfügung und die Ladezeit ist kürzer.
  • Page 8: Verhalten Bei Überschreiten Der Maximalen Pufferzeit

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 9 Verhalten bei Überschreiten der maximalen Pufferzeit Die Pufferzeiten sollten nicht überschritten werden. Das System sollte innerhalb der Pufferzeit runtergefahren sein. Falls es zu einer Überschreitung der Pufferzeit kommt, werden die Supercaps tiefentladen und in Abhängigkeit vom Strom bricht die Ausgangsspannung zusammen.
  • Page 9 DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 UPSIC-2403 Standby @ No Load >30 min, @ nom.)Cap. & 25 °C 180 sec. 170 sec. 160 sec. 150 sec. Application example with 140 sec. mITX Board IMB-154 130 sec. 120 sec. (see parameters below) 110 sec.
  • Page 10: Software Ups Control Center

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 10 Software UPS Control Center Die Software steht auf unserer Hompage www.bicker.de direkt beim Produkt zum kostenlosen Download zur Verfügung. Die Software kann unter folgenden Systemen betrieben werden: Ab Windows® 7 Home / Professional / Enterprise / Embedded 32bit und 64bit Ab .Net Framework 4.5...
  • Page 11: Sicherheitshinweise

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 Execute file at shutdown: Wenn aktiviert, wird das ausgewählte Programm oder Skript / Batch ausgeführt bevor das Betriebssystem heruntergefahren wird. Die interne Programmierroutine von »UPS Control Center« stellt sicher, dass das Programm oder Skript/Batch zu Ende ausgeführt wird, bevor das System herunterfährt.
  • Page 12 DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 DC2412-UPS | DC2412-UPS-LD UPSIC-1205 | UPSIC-2403...
  • Page 13 DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 Intended use ................14 Technical drawing and pin assignment ........ 14 Technical data ................15 Installation .................. 15 Commissioning ................15 DC2412-UPS-LD ..................15 DC2412-UPS ....................16 UPSIC-1205 / UPSIC-2403 ..............16 Overvoltage protection („Load Dump“ funktion) ....16 Charging time super caps ............
  • Page 14: Intended Use

    Electronic accepts no liability for any omissions or faults. We will appreciate any notifica- tions regarding faults, suggestions for improvements and criticism. The intended use of the DC/DC converter DC2412-UPS and DC2412-UPS-LD is the con- version from 24 VDC to 12 VDC and bridging of short power failures. As a storage medi- um super caps are used (also known as ultra-capacitor or EDLC).
  • Page 15: Technical Data

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 J301 Pin assignment Connector J301 I 2 C RS232 01 DCD signal 10 SMB alert 02 DSR signal (Low = Cap >90 %; 11 GND High = Cap <90 %) 12 XSDA I²C...
  • Page 16: Dc2412-Ups

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 5.2 DC2412-UPS After connecting the supply voltage the device starts up, the output supplies 12 V and the super caps are charged. 5.3 UPSIC-1205 / UPSIC-2403 After connecting the supply voltage (UPSIC-1205 V >...
  • Page 17: Charging Time Super Caps

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 7 Charging time super caps The main part of the current is transferred to the output, a part is used to charge the super caps. At low loads there is correspondingly more charging current available and the charging time is shorter.
  • Page 18: Behaviour During Exceed Of Maximum Buffer Time

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 9 Behaviour during exceed of maximum buffer time The buffer times should not be exceeded. The system should be shut down within the buffer time. If buffer time exceeds, the super caps are deep-discharged and the output voltage collapses as a function of the current.
  • Page 19 DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 UPSIC-2403 Standby @ No Load >30 min, @ nom.)Cap. & 25 °C 180 sec. 170 sec. 160 sec. 150 sec. Application example with 140 sec. mITX Board IMB-154 130 sec. 120 sec. (see parameters below) 110 sec.
  • Page 20: Software Ups Control Center

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 10 Software UPS Control Center The UPS software is available for free download directly on the product page at www.bicker.de. The software runs under the following systems: Windows® 7 Home / Professional / Enterprise / Embedded 32bit und 64bit or higher .Net Framework 4.5 or higher...
  • Page 21: Safety Instructions

    DC2412-UPS | DC2412-UPS-LD | UPSIC-1205 | UPSIC-2403 Execute file at shutdown: When enabled, the selected program or script/batch is executed before the operating system shuts down. The internal programming routine of „UPS Control Center“ ensures that the program or script/batch is executed completely before the computer shuts down.
  • Page 22 Bicker Elektronik GmbH Ludwig-Auer-Straße 23 86609 Donauwörth · Germany Tel. +49 (0) 906 70595-0 +49 (0) 906 70595-55 Irrtümer und technische Änderungen vorbehalten. Windows® ist ein eingetragenes Warenzeichen der Firma Microsoft Corp. E-Mail info@bicker.de Subject to errors and technical modifications.

This manual is also suitable for:

Upsic-1205Dc2412-ups-ldUpsic-2403