Tinker&Rasor M/2 Product Instructions

Wet sponge holiday detector

Advertisement

Quick Links

P. O. B
1667 S
OX
AN

Unpacking Checklist

The Model M/2 Holiday Detector Kit includes the following:
(1) Model M/2 Unit (085-156)
(1) Battery, 9v (010-007)
(1) Cable, Ground (026-101)
(1) Water Wetter Solution, 4oz (049-013)
(1) Wand, 16" (177-070)
(1) Sponge Assembly (ships assembled)
(1) Sponge (055-882)
The information contained in this document is subject to change without notice and does not represent a
commitment on the part of Tinker & Rasor.
Any and all reproduction or transmission of any part of this manual, in any form or by any means and for
any purpose other than the personal use by the purchaser is strictly forbidden without the express written
authorization of Tinker & Rasor.
For updates, please visit our website:
http://tinker-rasor.com
© 2018 Tinker and Rasor, Inc.
All rights reserved.
Web: www.tinker-rasor.com
CORROSION MITIGATION INSTRUMENTATION
B
, C
92402
ERNARDINO
A
P
RODUCT
MODEL M/2
WET SPONGE HOLIDAY DETECTOR
Page 1 of 6
T
: (909) 890-0700
EL
I
NSTRUCTIONS
(1) Holder, Yellow (076-050)
(1) Knob, sponge holder (094-030)
(1) Sponge bracket (014-195)
(1) Canvas tote bag
(1) Screwdriver
(1) Instructions
(1) Warranty/Calibration Document
E-mail: Info@tinker-rasor.com
F
: (909) 890-0736
AX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the M/2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tinker&Rasor M/2

  • Page 1 RODUCT NSTRUCTIONS MODEL M/2 WET SPONGE HOLIDAY DETECTOR Unpacking Checklist The Model M/2 Holiday Detector Kit includes the following: (1) Model M/2 Unit (085-156) (1) Holder, Yellow (076-050) (1) Battery, 9v (010-007) (1) Knob, sponge holder (094-030) (1) Cable, Ground (026-101)
  • Page 2 The detector is a “non-destructive wet sponge” type holiday detector. The basic electronic design of the Model M/2 Holiday Detector is that of a very sensitive circuit which is energized by one 9v battery. When current of 500 or 700 (+/- 10/%) micro-amperes flows in the circuit, an audible and visual signal is actuated.
  • Page 3 Saturate the sponge in a wetting solution. CALIBRATION Factory calibration on Model M/2 Holiday Detectors is for the voltages and resistances of each of the four (4) output settings. All voltages are calibrated to a tolerance of +/- 5%.
  • Page 4 The Model M/2 is turned ON by pressing the Power On/Off button on the instrument panel. When powered On, the M/2 will flash the Blue LEDs through each of the four (4) output voltages. Once the LED’s flash through once, the LED will indicate the selected output voltage.
  • Page 5 ACCESSORIES The M/2 uses the same accessories as the Tinker & Rasor Model M/1S Stick Unit. All accessories included with the instrument (page 1 list) are available for purchase, including additional sponges. Sponge electrodes are available in standard size, as included with new instruments, or as custom size widths, or as disks for internal pipeline coatings.
  • Page 6 CORROSION MITIGATION INSTRUMENTATION P. O. B 1667 S 92402 : (909) 890-0700 : (909) 890-0736 ERNARDINO RODUCT NSTRUCTIONS TROUBLESHOOTING ISSUE ASSUMPTION SUGGESTION NO LED battery not present, or too low Replace 9v battery of voltage to power instrument ALARM VISUAL Ground connection issue.

Table of Contents