ADT Security Service iHub-3000B Installation Manual

When used with the concord 4 security panel

Advertisement

  
 
iHub‐3000B 
Installation Guide 
When used with the  
Concord 4 Security Panel  
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iHub-3000B and is the answer not in the manual?

Questions and answers

Summary of Contents for ADT Security Service iHub-3000B

  • Page 1      iHub‐3000B  Installation Guide  When used with the   Concord 4 Security Panel      ...
  • Page 2: About This Guide

           Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel  Copyright © 2010 ADT Security Service, Inc. All rights reserved.  About This Guide  This document does not cover the physical installation and special configurations that may be required  for the security system components. Refer to the manufacturer's documentation for each device for  those specifics.    Overview of the Installation Process  The installation utilizes a streamlined process for setting up the system.  All components are individually  activated and tested before being physically installed in their final locations, whenever possible.          2    ...
  • Page 3: Connecting The Hardware

              Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel  Activating the Service with Concord 4 Security Panel  Before you begin the activation process, you must make some hardware connections. Since each  security panel is different, follow the instructions in the next section, "Connecting the Hardware", for  the specific security panel you are installing. Then please follow the instructions in "Activating the  Service" on page 3 for all security panels.  Connecting the Hardware  Follow the procedure in this section that applies to the security panel you are installing.  Note:    Do not connect the iHub gateway's power supply to an electrical outlet until you  are instructed to do so by the activation wizard. If you power on the gateway before it is  connected to the Internet, it cannot retrieve the information it requires on power up. If you  have already done this, simply unplug it and continue with the following instructions.   If you are installing a Touch Screen, do not connect it to a power source until you are  instructed to do so by the activation wizard.  To connect the gateway to the Concord 4 security panel:  1.  Wire the Automation Module to the Concord's bus, as described in the GE Installation Manual.   2.  Gateway model iHub‐3000B‐ADT, connectors are labeled Tx+, Tx‐, Rx+, and Rx‐. The automation  module connectors are labeled the same but might include a/b instead of +/‐. Using a standard 4‐ wire security cable, connect the ports on the gateway's RS422 bus to the Automation Module as  follows:  Gateway  Automation Module  Tx+  Rx+ or Rxb  Tx‐  Rx‐ or Rxa  Rx+  Tx+ or Txb  Rx‐  Tx‐ or Txa    Do not connect any antenna provided to the port on the gateway labeled Cellular. Cellular  communications from the iHub are not used.   Activating the Service  To activate the service: ...
  • Page 4        Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    3.  After reading the information on the screen, click Continue.  The Select Hardware screen appears.    4.  Select the type of hardware you are installing, and click Continue.  The Enter Activation Key screen appears.  4    ...
  • Page 5           Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    5.  Enter the activation key, and click Continue.  Note:    The activation key contains numbers from 0‐9 and letters from A‐F.  There are no letters O or I.  The activation process begins, and then the Select Service Options screen appears.    6.  Select the appropriate options for the installation based on the information on the Installer  Reference Sheet, and click Continue.  The Physical Setup screen appears. The exact wording on this screen varies based on the security  panel you are installing and the service options you selected on the previous screen.  5     ...
  • Page 6        Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    7.  Follow the instructions on the screen, and then click Continue.  A message displays a progress bar, which indicates approximately how much longer the activation  will take. If an upgrade is required, the activation application performs the upgrade automatically.  If the power light blinks amber, it indicates that an upgrade is in process.  6    ...
  • Page 7: Creating A User Account

              Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel  Assigning the Site Owner  The next step in the procedure is to set the site owner, configure the site settings, and sign in to the web  portal to complete the installation process. The user selection screen should still be displayed on the  computer. This screen offers the option of creating a new user account or using an existing user account.    Take one of the following actions:    If the customer does not have a user account, click Create New User Account. The Create User  Account screen appears. Continue with "Creating a User Account" on page 7.     If the customer already has a user account, enter their username on the right side of the screen,  and click Continue. Skip the next section and continue with "Configuring Site Information" on  page 8.  Creating a User Account  For customers who do not yet have a user account, you must create one. The user account enables you  to complete the installation process and then for the customer to access their security system online or  from a mobile device anytime they want. (If the customer already has a user account, skip this section.)  To create a new user account:  1.  On the Activate Service sign in screen, click Create New Account.  The Create User Account screen appears.  7     ...
  • Page 8        Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    2.  Enter the required information for the customer.   Enter the username that the customer prefers. Depending on how your the system is configured,  the username might be restricted to a certain number of characters.  3.  Click Continue.  The Site Information screen appears. Continue with "Configuring Site Information" on page 8.  Configuring Site Information  When you click Continue on either the user selection screen or the Create User Account screen, the Site  Information screen appears.  8    ...
  • Page 9           Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    Note:    Depending on how the system is configured, this screen might not require you  to enter all of the information shown in this example.   To configure the site information:  1.  Enter the required information from your Installer Reference Sheet, and then click Next.  Note:    The Security Panel User Access Code must match the same access code in the  ADT Pulse portal. For example if the user access code is 1234 (not recommended), the ADT  Pulse setting must also be 1234 or remote control will not be possible.  The installer should inform the customer that if they ever change their keypad user code  they must also change the code in the ADT Pulse web portal.     A message informs you that the service is now active.  Note:    If the service is not successfully activated, please refer to the Pulse  Troubleshooting guide for help.  2.  Click Go to Portal.  The installer sign in page appears.  9     ...
  • Page 10        Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel    3.  Enter your installer password in the Installer Password field, and click Sign In.  The web portal launches and displays a site status message at the top of the page indicating that  the site is in install mode.  4.  If you have not yet installed the security sensors, continue with "Adding GE Security Sensors and  Remotes" on page 13. If you have already installed the sensors, continue with the next section.  Note:    If you click Run Diagnostics, it launches the Site Diagnostics Tool. (Refer to the  separate documentation for that internal tool.)  Note:    To reset an inclusion controller, follow the manufacturer's instructions.  10    ...
  • Page 11           Installation Guide for the iHub‐3000B‐ADT and the Concord 4 Security Panel  Specifications,  Approvals and Certifications.   Ethernet 1 (10/100 Mbit/sec port) 1 (10/100 Mbit/sec port) Wireless WiFi IEEE 802.11b/g Z-Wave Built-in Z-Wave module Wired Control RS422 1 (External RS422 by screw terminal connector) Interface 2 (for future expansion) JTAG 1 (for development / debug) Software Applications Linux 2.4 BSP Ready...
  • Page 12: Fcc Warning Statement

    FCC Warning statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

Table of Contents