    1 DESCRIPTION The AIR DPS Sensor is an electro-sensitive device for the detection of individuals, specifically designed to provide safety to Manusa sliding doors. This sensor complies with all the requirements specified in the Standard EN 16005. LCD screen Cover...
  • Page 3 Any servicing or repair works on the sensor should only be carried out by manusa. Any other use of the device different from its intended purpose shall be excluded from the manufacturer’s guarantee.
  • Page 4 D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 1.4 TECHNICAL DATA 12V - 30V DC +/-10% Power supply To be operated from SELV-compatible power supplies only Power consumption < 2.5W Mounting height 2 to 3.5 m (internal regulations may affect the acceptable mounting height) Operating temperature -25°...
  • Page 5: Commissioning

    D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2 COMMISSIONING The recommended commissioning sequence is as follows: installation, connection, start-up and settings. 2.1 MOUNTING 2.1.1 STANDARD MOUNTING 1. Remove the protective cover 2. Connect the cable 3. Position the drilling template 4.
  • Page 6 D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2.1.3 CEILING MOUNTING (OPTIONAL) Screw together Clip Clip Unclip Unclip Clip Clip 2.1.4 MOUNTING WITH RAIN PROTECTION (OPTIONAL)
  • Page 7 D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2.2 WIRING VERDE 12-30V POWER SUPPLY MARRÓN AC-DC AMARILLO OPENING INPUT BLANCO ROSA SAFETY OUTPUT GRIS SAFETY INPUT VIOLET PULL-UP** *Output condition when the sensor is in operation. ** Bravo only, connect to 12V 2.2.1 CONNECTION TO VISIO OPERATOR FOR OPENING PROTECTION 2.2.1.a Connection to a sensor Sensor...
  • Page 8 D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2.2.2 CONNECTION TO VISIO OPERATOR FOR CLOSING PROTECTION Sensor Green Brown Pink Grey Note: Configure the following parameter: PULSE INPUT = positive 2.2.3 CONNECTION TO BRAVO OPERATOR FOR CLOSING PROTECTION Note: Configure the following parameters: PULSE INPUT = positive Sensor Green...
  • Page 9 D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2.3 SAFETY FIELD SETTING - INFRARED CLOSER FARTHER ≤ 9 cm Press twice to activate the If necessary, adjust the angle of the visible spot. infrared curtains (from -7º to +4º) *Visibility depends on external conditions. If the spots are not visible, the Spotfinder helps to locate the position of the curtains. **The distance between the inner curtain of the inside door sensor and the inner curtain of the outside door sensor should always be less than 20cm The distance up to the door leaf depends therefore on the thickness of the door leaf.
  • Page 10 DDS-SSENSOR - INSTALLATION MANUAL 2.5 SETUP After SETUP, check that the installation operates correctly before signing off on the setup process. IMPORTANT! After DDS-S setup do a self learning procedure for door automation (Visio) 2.5.1 QUICK SETUP = OK Vacate the detection field...
  • Page 11: Lcd Screen

    D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 2.6 USING THE LCD SCREEN 2.6.1 INSTRUCTIONS DURING NORMAL OPERATION Safety Opening impulse To adjust the contrast, simultaneously press and turn the grey button Negative display = Active output 2.6.2 FACTORY VALUE vs. SAVED VALUE Displayed value = Factory value Displayed value = Saved value 2.6.3 NAVIGATING THE MENUS...
  • Page 12: User Menu

    D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 3 USER MENU NAVIGATION MAP: BASIC MENU Back Next PRESETTINGS Standard: factory values Critical Environment: increased immunity For conformity with EN 16005 / DIN 18650, use values 6 y 7 at a mounting height ≥ 2,8m. BS7036: for a mounting height ≥...
  • Page 13: Troubleshooting

    D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 4 TROUBLESHOOTING Error Solution STATUS The sensor signals an 1. Replace the sensor. internal fault Flashes once 1. Check the power supply in the diagnostics menu. The power supply is too low or too high.
  • Page 14: Installation Checklist

    D00729EN - v2 DDS-SSENSOR - INSTALLATION MANUAL 5 INSTALLATION CHECKLIST Check that the sensor has been firmly installed to avoid external vibrations. Do not cover the sensor. There are no moving objects or light sources in the detection field. There are no reflective objects (mirrors, stainless steel objects…) in the IR area. The operator cover is perfectly fitted.
  • Page 15: Declaration Ce Of Conformity

    Product: Electro-sensitive device for the detection of the presence of individuals, suitable for installation in automatic pedestri- an doors. Model: DDS-S SENSOR Ref: A05039 Notified body : TÜV NORD CERT GmbH, Langemarckstrasse 20, D-45141 Essen, NB 0044, EC-type-examination certificate No. 44 799 12 405836-001.
  • Page 16 Av. Vía Augusta, 85-87, 6 Floor al obligation. 08174 Sant Cugat del Vallés Barcelona - España The manufacturer reserves the right to make modifications Tel. +34 902 321 400 without prior warning Fax +34 902 321 450 Last revision: July 2015 www.manusa.com...