Focus ABH-50L Installation Manual

Abh 4 beams active photoelectric intruder detector with digital frequency conversion

Advertisement

Quick Links

ABH 4 BEAMS ACTIVE PHOTOELECTRIC INTRUDER
DETECTOR WITH DIGITAL FREQUENCY CONVERSION
INSTALLATION GUIDE

Advertisement

loading

Summary of Contents for Focus ABH-50L

  • Page 1 ABH 4 BEAMS ACTIVE PHOTOELECTRIC INTRUDER DETECTOR WITH DIGITAL FREQUENCY CONVERSION INSTALLATION GUIDE...
  • Page 2 Model: ABH-50L (Outdoor 50m, Indoor 150m) ABH-100L (Outdoor 100m, Indoor 300m) ABH-150L (Outdoor 150m, Indoor 450m) ABH-200L (Outdoor 200m, Indoor 600m) ABH-250L (Outdoor 250m, Indoor 750m) Wiring hole Wiring terminal Tamper switch Voltage test hole Indicator Response time adjustment knob...
  • Page 3 The base is unstable Adjustable angle: horizontal 90 vertical 10 Direct sunlight, lamplight etc. Horizontal 180 ( 90 ) 200mm ertical 10 Style uarding distance Beam spread diameter 200mm 0.8m ABH-50L ABH-100L 100m 1.6m ABH-150L 150m 2.4m ABH-200L 200m 3.2m ABH-250L 250m 4.0m...
  • Page 4 1.Remove the cover Installation of fixed bracket 1.Drill a hole on the bracket and extend out the cable from it. 2.Attach the paper stencil onto the location where the equipment is to be mounted, and drill the holes in the positions on its mark. 2.Remove the cover.
  • Page 5 Visual test method Up 2 beams 1.Remove the cover and connect power. Down 2 beams 2.Observe the collimation effect at a distance of 5cm from the viewfinder. Adjust the upper / lower angle regulation screw and horizontal adjustment wheel in order that the image of opposite detector falls into the central part of the viewing hole.
  • Page 6 Please see the diagram to adjust the response time of the receiver. Usually, the time set shall be less than the time when the intruder crosses the guarding area. High speed ast running(6.9m/s): ast walking (1.2m/s):3 ormal walking (0.7m/s):4 low walking (0.4m/s):5 alking test is required after the setting, physical test in accordance to below diagram...
  • Page 7 7.Re-adjust the response time 7.Response time too short 8.Re-adjust the optical axis, and make the signal 8.Level 5 LED does not light up before the cover is reception reaches its top. put on Model ABH-50L ABH-100L ABH-150L ABH-200L ABH-250L Outdoor 100m...
  • Page 8: Recommended Installation

    Recommended installation -shaped bracket T-100 100 120mm T-200 Installation bracket 200 120mm -shaped bracket I-100 100mm I-200 L-shaped bracket 200mm 80 75mm Dimensions The product has got the 3C and CE approval already and is now applying for the UL approval. Copyright : Shenzhen Meian Technology Co.,Ltd.