Table of Contents
loading

Summary of Contents for CellarCool cx2200

  • Page 1 CX SERIES OWNER’S MANUAL cx2200 cx3300 cx4400 cx8800...
  • Page 2 CellarCool. Every effort has been made to ensure that the information in this manual is accurate. CellarCool is not responsible for printing or clerical errors.
  • Page 3: Table Of Contents

    & cx3300 ........
  • Page 4: Introduction

    INTRODUCTION Customer Service Thank you for purchasing a CellarCool cooling system. We strive to provide the highest-quality products and the best possible customer service. If you have any questions about your system, please call us at 1-800-343-9463 or visit cellarcool.com.
  • Page 5: Before You Start

    CX SERIES BEFORE YOU START This guide is meant to serve as a quick reference for installation of the CellarCool unit. The remainder of this owner’s manual will provide more detailed information and instructions. Upon receiving the CellarCool cooling unit: 1.
  • Page 6: Receiving & Inspecting The Unit

    NOTE: CellarCool units are manufactured in the USA and tested prior to shipment. Please leave the CellarCool unit in its original box until you are ready for installation. This will allow you to move the product safely without damaging it. When you are ready to remove the product from the box, refer to the installation instructions.
  • Page 7: Quick Reference Guide

    QUICK REFERENCE GUIDE Front / Side View ON/OFF switch (for 4400 & 8800 models only) Air sensor Power cord Controller (front location standard) Rear / Side View Power cord (rear location optional) Rear drain port Access door www.cellarcool.com | Page 5...
  • Page 8: Specifications

    UNIT SPECIFICATIONS cx2200 cx3300 cx4400 cx8800 Cellar Size (cu. ft.)* 1000 2000 14.25"W x 13.25"H x 16.25"W x 22"H x Dimensions 14.25"W x 19.75"H x 21.63"D 16.38"D 22.25"D Weight (lb.) Amps (running) Installation Through the wall Thermostat Digital display 30°F temperature differential between wine cellar and ambient temperature Temp.
  • Page 9: Preparing The Wine Cellar

    Insulation Insulation is REQUIRED in order to properly use CellarCool products. It is vital that all walls and ceilings be insulated to keep the cellar temperature as consistent as possible during the summer and winter months. Standard fiberglass or rigid foam insulation is normally used in cellar construction;...
  • Page 10: Installation

    Ventilation The necessity of dissipating heat away from the unit is critical to the unit’s performance and cannot be overstated. As the unit operates and cools, a greater amount of heat is generated on the exhaust side of the unit. Adequate ventilation is required in order to dissipate heat away from the unit.
  • Page 11: Airflow Control

    NOTE: Do not cover both of the openings on the same side of the unit for any reason. This will cause cooling issues and premature failure. NOTE: If installing the magnetic deflectors on the face of the cx4400 unit, excess material may need to be trimmed. www.cellarcool.com | Page 9...
  • Page 12: Preparing The Installation Location

    The system is wider than the 16 inches at which wall studs are typically spaced, and will require the removal of at least one stud. Using a ruler or measuring tape, measure vertically down 13.5 inches for the cx2200, 20 inches down for the cx3300/cx4400, and 22.5 inches for the cx8800. Mark another hori- zontal line parallel to the first one.
  • Page 13: Preparing The Unit For Installation

    Note: If you use decorative moulding, it should be Cellar Wall attached to the walls and never to the cooling unit itself. The moulding itself should be removable incase the unit needs servicing. Front of Unit www.cellarcool.com | Page 11...
  • Page 14 Mounting Bracket Installation Select your desired bracket mounting location (see diagram below). This location determines the depth of the installation. For example, position #1 keeps most of the unit out of the cellar, while position #2 makes the back of the unit almost flush with the exterior wall.
  • Page 15: Drain Line

    It is important that the drain line tube be properly connected and used to prevent leakage and other problems associated with excess condensation. If the drain line is draining into a vessel, make sure that the drain line hangs above the surface and is not submerged. This will prevent the formation of mold. www.cellarcool.com | Page 13...
  • Page 16: System Operation

    Setpoint cycle off for 10 minutes and on for 40 minutes. “E1” will be The setpoint is preset at the factory (CellarCool) to 55F°. It can displayed on the screen. be adjusted by the customer between 50°F and 70°F (in 1°F Alarms increments).
  • Page 17: Controller Functions

    The unit is in defrost mode. The compressor and fans will be turned off during this cycle. ALARM The alarm symbol is shown when the unit encounters an issue that needs attention. The displayed alarm codes are explained on the next page. The alarm code will remain displayed until corrected. www.cellarcool.com | Page 15...
  • Page 18 ALARM CODES Message Cause Solution “E1” Faulty air-sensing probe Contact Customer Service at 1-800-343-9463. The air probe is sensing 1. Allow time for the wine to reach the desired temperature. “AH1” a temperature that is 10° 2. Make sure all windows and doors are closed and have a proper seal. above the setpoint 3.
  • Page 19: Cx2200 & Cx3300

    CX SERIES cx2200 & cx3300 CONTROLLER WIRING SCHEMATIC www.cellarcool.com | Page 17...
  • Page 20: Cx4400

    cx4400 CONTROLLER WIRING SCHEMATIC  040418 Page 18 | 1-855-235-5271...
  • Page 21: Cx8800

    CX SERIES cx8800 CONTROLLER WIRING SCHEMATIC www.cellarcool.com | Page 19...
  • Page 22 NOTES 040418 Page 20 | 1-855-235-5271...
  • Page 23: Troubleshooting Guide

    Controller set too high Lower the setpoint Evaporator coil is frosted or iced up Observe ice formation pattern. If only part way up the coil face, unit could be low on refrigerant. If so, call Customer Service at 1-800-343-9463. www.cellarcool.com | Page 21...
  • Page 24 TROUBLESHOOTING GUIDE Unit leaks water Possible cause Solution Unit is not level Unit should be level in wall to prevent leaking Drain line clogged or kinked Check drain line to make sure water can flow freely Drain is clogged, preventing water from escaping 1.
  • Page 25: Maintenance Schedule

    They are harmful or fatal if ingested. Wear protective gloves when handling pan tabs. Wash thoroughly after handling. If pan tabs make contact with eyes, rinse cautiously with water for several minutes. In case of an emer- gency, call 1-800-255-3924 (24 hours). www.cellarcool.com | Page 23...
  • Page 26: Technical Assistance & Accessories

    TECHNICAL ASSISTANCE CellarCool Customer Service is available Monday through Friday from 6:00 a.m. to 4:00 p.m. Pacific Standard Time. The appointed customer service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: •...
  • Page 27: Installation Terms & Conditions

    A. Two (2) Year Limited Warranty. For the period of TWO (2) YEARS (the “Limited Warranty Period”) from the date of original sale of a Product by CellarCool, if a CellarCool Product is found to be defective in material or workmanship after undergoing CellarCool’s customer service troubleshooting, then, subject to the CellarCool...
  • Page 28 15. No one has any authority to add to or vary the limited warranty on this Product. 3. Product Installation Requirements: A. Prior to installing a CellarCool Product, the End User must read the CellarCool Owner’s Manual and thereafter the End User must follow the required installation, use and maintenance procedures set forth by CellarCool in CellarCool’s Owner’s Manual.
  • Page 29 D. End User is responsible for all costs incurred for the installation and/or removal of the Product, or any part thereof, unless such cost has been agreed by CellarCool to be a warranty repair prior to the work being performed.
  • Page 30 Web: www.cellarcool.com B. Technical Assistance. CellarCool Customer Service is available Monday through Friday from 6:30 a.m. to 4:00 p.m. PST. The Customer Service representative will be able to assist you with your questions and warranty information more effectively if you provide them with the following: 1.