FIG. 12 WIRING FOR THREE PHASE UNITS WITH MANUAL SWITCH
L-1
L1
L-2
L2
L-3
L3
SEE CHART FOR
APPROPRIATE SWITCH
T1
T-1 T-2
T2
T-3
T3
FIG. 13 WIRING FOR THREE PHASE UNITS WITH MAGNETIC SWITCH
SWITCH START - STOP
(MOUNT NEAR UNIT)
START
STOP
SWITCH BOX ON
FRONT OF UNIT
SOLENOID-RATED
VOLTAGE TO MATCH
LINE VOLTAGE
CLOCKWISE
ROTATION
FIG. 14 WIRING FOR SINGLE PHASE UNITS WITH MANUAL SWITCH
L-1
L1
L-2
L2
T-1
T-2
T1
T2
®
®
C
O
M
M
E
R
C
I
A
L
by Anaheim Manufacturing
POWER SUPPLY -
FUSE PER
LOCAL CODE
MOTOR JUNCTION BOX
SOLENOID RATED VOLTAGE
TO MATCH LINE VOLTAGE
THESE TERMINALS MAY BE
LABELED T4 OR L4
3
2
L-3
T-3
T-2
L-2
T-1
L-1
MOTOR: CONSULT CHART FOR COR-
POWER SUPPLY -
RECT MAGNETIC SWITCH
FUSE PER LOCAL CODE.
TURNTABLE ROTATION
AS VIEWED FROM THE TOP
POWER SUPPLY -
FUSE PER
LOCAL CODE
MOTOR JUNCTION BOX
SOLENOID RATED VOLTAGE
TO MATCH LINE VOLTAGE
4240 E. La Palma Avenue, Anaheim, CA 92807 • (800) 454-4423 • fax (800) 246-3245 • www.wasteking.com
TURNTABLE
ROTATION
CLOCKWISE
ROTATION
AS VIEWED
FROM THE TOP
COIL RATED
VOLTAGE TO
MATCH LINE
VOLTAGE
TURNTABLE
ROTATION
CLOCKWISE
ROTATION
AS VIEWED
FROM THE TOP

MANUAL SWITCH

MODEL
VOLTS
WK PART NO.
208-240
2000
2 HP
460
208-240
3000
3 HP
460
208-240
5000
5 HP
460
NOTES:
1. Motor wired at Factory for 208-240 volts.
For 460 volts, connect motor wires as
shown inside of motor junction box cover.
2. Interchange T1 and T3 to reverse rotation.
3. Magnetic and manual starters, supplied
by Waste King do not require heaters to
complete the circuit. Disposers have
built-in overload protection.

MAGNETIC SWITCH

MODEL
VOLTS
WK PART NO.
208-240
2000
2 HP
460
208-240
3000
3 HP
460
208-240
5000
5 HP
460
208-240
10000
10 HP
460
NOTES:
1. Motor wired at Factory for 208-240 volts.
For 460 volts, connect motor wires as
shown inside of motor junction box cover.
2. Interchange T1 and T3 to reverse rota-
tion.
3. Magnetic and manual starters, supplied
by Waste King do not require heaters to
complete the circuit. Disposers have
built-in overload protection.
MANUAL SWITCH
MODEL
VOLTS
WK PART NO.
110-120
2000
2 HP
220-240
NOTES:
1. Motor wired at Factory for 220-240
volts. For 110-120 volts, connect motor
wires as shown inside of motor junction
box cover.
2. Magnetic and manual starters, supplied
by Waste King do not require heaters to
complete the circuit. Disposers have
built-in overload protection.
560P333P02
2420
2420
2421
2421
2421
2421
2416
2417
2416
2417
2416
2417
2416
2417
2420