Download Print this page

emaux SP500 Manual page 2

Advertisement

3) Replace filter coping (with O'ring in place).
a) Carefully screw pressure gauge (with O'ring in place) into tapped hole in the filter coping. Do not over-
tighten.
b) Ensure air relief valve (with O'ring in place) is tight fit to filter coping and turn it easily.
4) Connect pump to control valve opening marked PUMP.
5) Make return to pool pipe connection to control valve opening marked RETURN and complete other
necessary plumbing connections, suction lines to pump, waste, etc.
6) Make electrical connections to pump per pump instructions.
7) To prevent water leakage, be sure all pipe connections are tight.
MAIN DIMENSION
DIMENSION TABLE
High
Diameter
Valve
mm
mm
inch
Model
A
B
SP450
730
455
1.5 "
SP500
770
535
1.5 "
SP650
850
635
1.5 "
SP700
960
710
1.5 "
INSTALL/START-UP OF FILTER
1) Be sure correct amount of filter media sand is in tank and that all connections have been made and are
secure.
2) Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve
seal, always depress handle before turning.)
3) Prime and start pump according to pump instructions (be sure all suction and return lines are open),
allowing the filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at
least 1 minute. The initial back-washing of the filter is recommended to remove any impurities or fine sand
particles in the sand media.
4) Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear,
about 1/2 to 1 minute.Turn pump off and set valve to FILTER position and restart pump.The filter is now
operating in the normal filter mode, filtering dirt particles from the pool water.
5) Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and
tighten connections, bolts, nuts, as required.
6) Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending
upon the pump and general piping system.) As the filter removes dirt and impurities from the pool water,
the accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge
reading is 1.5 bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see
BACKWASH under filter and control valve functions).
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the
unusually heavy initial dirt load in the water.
Sand
kg
45
85
145
210
B
2-4
Key No.
Part No.
1
89010701
2
06021009
2
01111048
3
01201022
4
03021035
5
03011095
6
01271010
7
02011134
8
89010712
8
89010713
8
89010714
8
89010715
9
89010708
9
89010709
A
9
89010710
9
89010711
10
01111046
11
01172007
11
01172008
12
02011003
13
88280811B
14
89011601
15
01111059
15
01111062
REPLACEMENT PARTS OF FILTER
Description
Air Release Valve with O-ring
Plastic Pressure Gauge With O-Ring
Connector for Pressure Gauge/Stopper
Lid (Transparent)
M6 Nut
Screw
Clamp Lock
O-Ring for Filter Neck
SP450 Filter tank
SP500 Filter tank
SP650 Filter tank
SP700 Filter tank
S/SP450 the inner tank system
S/SP500 the inner tank system
S/SP650 the inner tank system
S/SP700 the inner tank system
1.5"Tank System Support
Laterals (115mm)
Laterals (126mm)
O-Ring for inlet & outlet
6 Way 1.5" Valve with Piping Kit, 1.5" union set x 3 and pressure gauge (Black)
Water Drain Set
16-21inch Filter Base
21-28inch Filter Base
3-4
Qty
1
1
1
1
2
2
2
1
1
1
1
1
1
1
1
1
1
8
8
2
1
1
1
1

Advertisement

loading

This manual is also suitable for:

Sp450Sp650Sp700