Link by nuts type valves

Advertisement

3) Assemble filter control valve into the filter tank.
a) Insert filter control valve (with O'ring in place) into the tank neck, taking care that the center pipe slips into the
hole in the bottom of the valve.
b) Place two plastic clamps around valve flange and tank flange and tighten just enough so that the valve may
be rotated on tank for final positioning.
c) Carefully screw pressure gauge (with O'ring in place) into tapped hole in valve body. Do not over-tighten.
d) Connect pump to control valve opening marked PUMP. After connections are made, tighten valve flange
clamps with screwdriver, tapping around clamp with screwdriver handle to help seat valve flange clamp.
4) Make return to pool pipe connection to control valve opening marked RETURN and complete other necessary
plumbing connections, suction lines to pump, waste, etc.
5) Make electrical connections to pump per pump instructions.
6) To prevent water leakage, make sure all pipe connections are tight.
MAIN DIMENSION
DIMENSION TABLE
Diameter
Valve Port
High
Size
Model
A
B
mm
mm
Inch
V900(C)
1334
900
2.5"
V1000(C)
1434
1000
2.5"
V1200(C)
1634
1200
2.5"
V1400
1780
1400
2.5"
INSTALL/START-UP OF FILTER
1) Make sure the correct amount of filter media sand is located in the tank and all connections have been
connected and secured.
2) Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve seal, always
depress handle before turning.)
3) Prime and start pump according to pump instructions (be sure all suction and return lines are open), allowing the
filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at least 1 minute. The initial
back-washing of the filter is recommended to remove any impurities or fine sand particles in the sand media.
4) Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear, about 1/2 to
1 minute. Turn pump off and set valve to FILTER position and restart pump. The filter is now operating in the normal
filter mode, filtering dirt particles from the pool water.
5) Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and tighten
connections, bolts, nuts, as required.
6) Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending upon the
pump and general piping system.) As the filter removes dirt and impurities from the pool water, the accumulation
of dirt in the filter will cause the pressure to rise and diminish the water flow. When the pressure gauge reading is 1.5
bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see BACKWASH under filter
and control valve functions).
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually
heavy initial dirt load in the water.
Sand
kg
470
620
860
1350
B
2-4
2
1
3
4
5
6
7
8
9
A
Item No.
Part No.
1
01013003 Handle (Big)
2
03018008 Pin for Handle
3
01181027 Washer for Handle(Black)
4
89281204 M6*33 T Screw with Nut
5
01021129 2.5"Top Mount Valve Standard Lid(Black)
6
02010228 O-Ring for 2.5" Valve Lid
7
02011022 O-Ring for 2.5" Valve Rotor
8
01181002 Washer for Spring(Black)
9
03014025 Spring for 2.5" Side Mount Valve
10
89280806 2.5" Valve Rotor With Spider Gasket
11
89280115 2.5" Side Mount Valve Bottom Body with Diffuser(Black)
12
02020053 O-Ring for 2.5"Union
01111048 Connector for Pressure Gauge/Stopper (Black)
13
89021303 Drain Plug with O'Ring (Black)
14
15
01013143 2.5"Connector(Black)
16
02010043 O-Ring for Union Adaptor
17
01171158 2.5"Union (A/E)(black)
18
01013147 2.5"Connector (black)
19
02010044 O-Ring for Diffuser
06011032 Oil Pressure Gauge with O-ring (40Psi)
20
21
89280104 Sight Glass With O-Ring
REPLACEMENT PARTS OF FILTER
Key No.
Part No.
1
88280307
2.5"Top Mount Valve
03013003 M8 Nut*12Pc; + 03012003
2
89010601
0M8 Washer*12Pc;
06011029
Oil Pressure Gauge With O-ring (40 psi)
3
01111048
Connector for Pressure Gauge/Stopper
4
89280116
2.5"Union set (3 pieces) with O-Ring
5
89280104
Sight glass with O-Ring
6
02011126
Filter Neck Gasket
89010604
V900C Filter Tank With Base
89010605
V1000C Filter Tank With Base
7
89010606
V1200C Filter Tank With Base
89010607
V1400 Filter Tank With Base
89010614
V900C Lateral Assembly With Center Pipe
89010615
V1000C Lateral Assembly With Center Pipe
8
89010616
V1200C Lateral Assembly With Center Pipe
89010671
V1400 Lateral Assembly With Center Pipe
10
89010617
V900C Laterals (233mm &115mm)
89010618
V1000C Laterals(129mm&185mm&115mm)
9
89010619
V1200C Laterals(129mm&233mm&115mm)
89010620
V1400 Laterals(129mm&233mm&126mm)
10
89010107
Water Drain Set
REPLACEMENT PARTS OF MULTIPORT VALVE
Product Description
Qty
1
1
1
12
1
1
2
1
1
1
20
1
3
21
2
2
3
3
3
3
1
1
1
3-4
Product Description
Qty
1
1
1
1
3
1
1
1
1
1
1
1
1
1
1
8
8
8
8
1
1
2
3
4
5
6
7
8
9
10
11
12 13
14
15 16
13
17
18
19

Advertisement

loading

This manual is also suitable for:

V900cV1200V1000V1000cV1400V1200c