Tangent Medix 1700SF User Manual

Tangent Medix 1700SF User Manual

Medical grade panel pc

Advertisement

Medix 1700SF
Medical Grade Panel PC
USER'S MANUAL
Copyright ©2008. All rights reserved
All brand names are registered trademarks of their respective owners.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Medix 1700SF and is the answer not in the manual?

Questions and answers

Summary of Contents for Tangent Medix 1700SF

  • Page 1 Medix 1700SF Medical Grade Panel PC USER’S MANUAL Copyright ©2008. All rights reserved All brand names are registered trademarks of their respective owners.
  • Page 2 Setup Thank you for purchasing the Medix 1700SF. Designed with durability and reliability in mind, the Medix 1700SF meets the demands in medical environments. Please follow all instructions to ensure maximum unit performance. Unpacking After opening the carton, there will be a Monitor display unit with an accessory box.
  • Page 3 2. Do not allow liquids to seep into the internal areas of the Monitor display unit. 3. Allowing liquids to seep in or inserting objects into the unit may result in electric shocks and/or short circuit of the internal parts. Medix 1700SF User’s manual...
  • Page 4 (3) Moisten a soft cloth with diluted neutral detergent to clean the unit. (4) Take a dry cloth and wipe the unit dry. Remember to avoid having liquids seep into the internal components and areas of the Monitor display unit. Servicing, Repairing, Maintenance & Safety Checks Medix 1700SF User’s Manual...
  • Page 5 4. When replacement parts are needed for the Monitor display unit, make sure service technicians use replacement parts specified by Tangent, or those with the same characteristics and performance as the original parts. If unauthorized parts are used it may result in starting a fire, electrical shock and/or other dangers.
  • Page 6: Table Of Contents

    Table of Contents Introduction............7 Product Description .......... 7 Package list ............. 8 Features ............9 Specifications ..........10 Dimension............12 System View ..........13 BIOS Setup............16 Appendix .............36 Medix 1700SF User’s Manual...
  • Page 7: Introduction

    The Medix 1700SF combines all the features of a powerful computer into a slim and attractive chassis. The Medix 1700SF has a 17” 400 nits TFT display with 1280 x 1024 resolution. The Medix 1700SF is a compact, Giga LAN and selectable WLAN network compatible PC with full safety and medical approval.
  • Page 8: Package List

    Package list Before you begin installing your Medical Station, please make sure that the following items have been shipped: • The Medix 1700SF Medical Panel PC • One CD containing user manual, Tangent drivers • Power Cable x 1 • Power Adapter x 1 •...
  • Page 9: Features

    Integrated TV tuner with capture card (optional) Integrated 1.3M pixel Web-CAM (optional) 802.11 b/g wireless LAN Module (optional) VESA 75/100 compliance Desktop Stand (optional) VESA 75/100 compliance Wall Mount (optional) Resistive touch screen (optional) Plastic construction with medical outlook color Medix 1700SF User’s manual...
  • Page 10: Specifications

    17” 420 nits SXGA color TFT LCD ® Medix 1700SF: Intel Core 2 Duo T7500 2.2GHz CPU Support ® Medix 1700SF (fanless): Intel Core 2 Duo Ultra Low Voltage U75001.06GHz Processor 2.5” Hard Disk Drive (SATA-150) Disk Drive Space Compact Flash Card reader One Mini PCI slot;...
  • Page 11 Note: All Tangent LCD products are manufactured with High precision technology. However, there are a small number of defective pixels in all LCD panels that are not able to change color. This is a normal occurrence for all LCD displays from all manufacturers and should not be noticeable or objectionable under normal operation.
  • Page 12: Dimension

    Dimensions Medix 1700SF User’s Manual...
  • Page 13: System View

    System View Front View Webcam (Optional) Control button at front panel From left to right 1. Brightness down 2. Brightness up 3. Power 4. Volume down 5. Volume up Medix 1700SF User’s manual...
  • Page 14 Rear View VESA 75/100 I/O parts Medix 1700SF User’s Manual...
  • Page 15 Side view Medix 1700SF User’s manual...
  • Page 16: Bios Setup

    Medix 1700SF BIOS Set up The Award BIOS provides a Setup utility program for specifying the system configurations and settings. The BIOS ROM of the system stores the Setup utility.
  • Page 17 These defaults have been carefully chosen by both Award and your system manufacturer to provide the absolute maximum performance and reliability. Changing the defaults could cause the system to become unstable and crash in some cases. Medix 1700SF User’s manual...
  • Page 18 It will adjust automatically according to the memory changed. The following describes each item of this menu. Date The date format is: Day : Sun to Sat Month : 1 to 12 Date : 1 to 31 Year : 1999 to 2099 Medix 1700SF User’s Manual...
  • Page 19 These fields identify the types of floppy disk drive A or drive B that has been installed in the computer. The available specifications are: 360KB 1.2MB 720KB 1.44MB 2.88MB 5.25 in. 5.25 in. 3.5 in. 3.5 in. 3.5 in. Medix 1700SF User’s manual...
  • Page 20 The system boot will not be halted for a disk error; it will stop for all other errors. All, But Disk/Key The system boot will not be halted for a key- board or disk error; it will stop for all others. Medix 1700SF User’s Manual...
  • Page 21 DRAM (system memory). CPUs from 486-type on up contain internal cache memory, and most, but not all, modern PCs have additional (external) cache memory. When the CPU requests data, the system transfers the requested data from the Medix 1700SF User’s manual...
  • Page 22 This field allows you to select how Gate A20 is worked. Gate A20 is a device used to address memory above 1 MB. Typematic Rate Setting When disabled, continually holding down a key on your keyboard will generate only one instance. When enabled, you can set the Medix 1700SF User’s Manual...
  • Page 23 If you are using Windows 95/98 without a floppy disk drive, select Enabled to release IRQ6. This is required to pass Windows 95/98's SCT test. You should also disable the Onboard FDC Controller in the Integrated Peripherals screen when there's no Medix 1700SF User’s manual...
  • Page 24 DRAM installed. Do not change the values in this field unless you change specifications of the installed DRAM or the installed CPU. DRAM RAS# to CAS# Delay Medix 1700SF User’s Manual...
  • Page 25 16 MB. The choices are Enabled and Disabled. On-Chip VGA Setting The fields under the On-Chip VGA Setting and their default settings are: PEG/On Chip VGA Control: Auto On-Chip Frame Buffer Size: 8MB Medix 1700SF User’s manual...
  • Page 26 18bit SC 1024x768 18bit SC 1280x1024 18bit DC 1280x768 18bit SC 1400x1050 18bit DC 1600x1200 18bit DC Onboard PCI-E LAN By default, this setting is disabled. LAN PXE Option ROM By default, this setting is disabled. Medix 1700SF User’s Manual...
  • Page 27 POWER ON Function BUTTON ONLY KB Power ON Password Enter Hot Key power ON Ctrl-F1 Onboard FDC Controller Disabled Menu Level > Onboard Serial Port 1 3F8/IRQ4 Onboard Serial Port 2 2F8/IRQ3 UART Mode Select Normal Medix 1700SF User’s manual...
  • Page 28 The fields under the SATA setting includes On-Chip Serial ATA (Auto), PATA IDE Mode (Secondary) and SATA Port (PO, P2 is Primary). USB Controller The options for this field are Enabled and Disabled. By default, this field is set to Enabled. Medix 1700SF User’s Manual...
  • Page 29 The default values for these ports are: Serial Port 1 3F8/IRQ4 Serial Port 2 2F8/IRQ3 UART Mode Select This field determines the UART 2 mode in your computer. The default value is Normal. Other options include IrDA and ASKIR. Medix 1700SF User’s manual...
  • Page 30 The default setting of the ACPI Suspend mode is S1(POS). RUN VGABIOS if S3 Resume The default setting of this field is Auto. Power Management This field allows you to select the type of power saving management modes. There are four selections for Power Management. Medix 1700SF User’s Manual...
  • Page 31 In the Delay 4 Sec mode, the system powers off when the power button is pressed for more than four seconds or enters the suspend mode when pressed for less than 4 seconds. Wake up by PCI Card Medix 1700SF User’s manual...
  • Page 32 INT Pin 3 Assignment devices Auto INT Pin 4 Assignment Auto INT Pin 5 Assignment Auto INT Pin 6 Assignment Auto INT Pin 7 Assignment Auto INT Pin 8 Assignment **PCI Express relative items** 4096 Maximum Payload Size Medix 1700SF User’s Manual...
  • Page 33 System FAN Speed 5400 RPM CPU FAN Speed 5400 RPM Vcore(V) 1.02 V 12 V 1.32 V 1.8V 1.8V -5.02V 5.25 V -12V -12.59 3.3V 3.37V VBAT (V) 3.21 V 5VSB(V) 5.67 V Smart Fan2 Temperature Disabled Medix 1700SF User’s manual...
  • Page 34 This field enables or disables the auto detection of the PCI clock. Spread Spectrum Modulated This field sets the value of the spread spectrum. The default setting is Disabled. This field is for CE testing use only Medix 1700SF User’s Manual...
  • Page 35 Select this option to exit the Setup utility without saving the changes you have made in this session. Typing “Y” will quit the Setup utility without saving the modifications. Typing “N” will return you to Setup utility. Medix 1700SF User’s manual...
  • Page 36: Appendix

    Parallel Port #1(LPT1) 360 - 36F Network Ports 3B0 - 3BF Monochrome & Printer adapter 3C0 - 3CF EGA adapter 3D0 - 3DF CGA adapter 3F0h - 3F7h Floppy Disk Controller 3F8h - 3FFh Serial Port #1(COM1) Medix 1700SF User’s Manual...
  • Page 37 Marvell Yukon 88E8053 PCI-E Gigabit Ethernet Controller (PCI) IRQ16 Mobile Intel(R) 915GM/GMS,910GML Express Chipset Family (PCI) IRQ17 Realtek AC97 audio (PCI) IRQ18 Intel(R) 82801FB/FBM USB Universal Host Controller– 265A (PCI) IRQ19 Intel(R) 82801FB/FBM USB Universal Host Controller– 2659 Medix 1700SF User’s manual...
  • Page 38 APPENDIX (PCI) IRQ19 Texas Instruments OHCI Compliant IEEE 1394 Host Controller (PCI) IRQ20 Intel(R) RPO/100 VE Network Connection (PCI) IRQ23 Intel(R) 82801FB/FBM USB Universal Host Controller– 2658 (PCI) IRQ23 Intel(R) 82801FB/FBM USB2 Enhanced Host Controller– 265C Medix 1700SF User’s Manual...
  • Page 39 (argc != 2) printf(" Parameter incorrect!!\n"); return 1; if (Init_W627EHF() == 0) printf(" Winbond 83627HF is not detected, program abort.\n"); return 1; bTime = strtol (argv[1], endptr, 10); printf("System will reset after %d seconds\n", bTime); EnableWDT(bTime); return 0; Medix 1700SF User’s manual...
  • Page 40 // PURPOSE. //================================================================ =========== #include "W627EHF.H" #include <dos.h> //================================================================ =========== unsigned int W627EHF_BASE; void Unlock_W627EHF (void); void Lock_W627EHF (void); //================================================================ =========== unsigned int Init_W627EHF(void) unsigned int result; unsigned char ucDid; W627EHF_BASE = 0x2E; result = W627EHF_BASE; Medix 1700SF User’s Manual...
  • Page 41 REG); Result = inportb(W627EHF_DATA_PORT); Lock_W627EHF(); return Result; //================================================================ =========== //================================================================ =========== // THIS CODE AND INFORMATION IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY // KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE Medix 1700SF User’s manual...
  • Page 42 =========== #define W627EHF_REG_LD 0x07 //================================================================ =========== #define W627EHF_UNLOCK 0x87 #define W627EHF_LOCK 0xAA //================================================================ =========== unsigned int Init_W627EHF(void); void Set_W627EHF_LD( unsigned char); void Set_W627EHF_Reg( unsigned char, unsigned char); unsigned char Get_W627EHF_Reg( unsigned char); //================================================================ =========== #endif //__W627EHF_H Medix 1700SF User’s Manual...
  • Page 43 APPENDIX Medix 1700SF User’s manual...

Table of Contents