Download Print this page

Pulsarlube E series User Manual

60ml /120ml / 240ml

Advertisement

Quick Links

Product Details
Housing
Cap
Mode
Selector
Connecting
Thread (1/4" PT)
Installation/Disposal Guidelines
1
3
Battery Cover
Battery
Remove contaminants around
Remove the protector.
the lube point.
PCB
2
4
Piston
Lubricant
Reservoir
Ensure a clear passage using a manual
Turn the housing cap counterclockwise
grease gun.
Remove any hardened grease
and unscrew the cap.
Note1
by purging the lube point with a manual grease gun.
Base
The grease in the equipment and the grease
Note2
contained in the unit should be the same or compatible.
5
Note
Protector
Remove the grease nipple and install
Pull out the red Mode Selector from the
appropriate adaptors.
default OFF position.
6
9
Firmly push the Mode Selector into the slot
When the selected dispensing period of
of the desired period.
the Pulsarlube E has completed, remove
the lubricator from the application.
7
10
To position the window properly, align the
The Pulsarlube E is an eco-friendly product that can
be disposed of separately. Turn the housing cap
on the housing cap with the on the body.
counterclockwise to disassemble the product for
proper disposal.
8
11
Note the installation date and the scheduled date of
Unscrew the screws to remove the battery
lube cycle completion on the label of the Pulsarlube E.
cover.
Note
Please note there is a delay before the actual dispensing
starts. It may take up to 1~3 weeks for enough gas to be formed
depending on the dispensing setting & installation condition.
Mounting Installations
High backpressure can cause a delay
12
in dispensing (must be under 5 bar).
Remove the batteries.
If the product is installed at a 45°
or 90° angle, please use an angle
adapter with a diameter greater than
or equal to 1/4".
13
Using a hand tool such as a flat-head
screwdriver, detach the PCB from the unit.
For remote installation using an 8mm
14
O.D. tubing, keep the maximum
distance at 1m (3ft) or less.
Dispose of remaining plastic components
complying with local regulations for recycling.
Do not cut, puncture, or reuse lubricator.
Warning

Advertisement

loading
Need help?

Need help?

Do you have a question about the E series and is the answer not in the manual?